Multivariate outlier mining and regression feedback for 3D measurement improvement in opto-mechanical system

被引:21
作者
Flores-Fuentes, Wendy [1 ]
Sergiyenko, Oleg [1 ]
Gonzalez-Navarro, Felix F. [1 ]
Rivas-Lopez, Moises [1 ]
Rodriguez-Quinonez, Julio C. [1 ]
Hernandez-Balbuena, Daniel [1 ]
Tyrsa, Vera [1 ]
Lindner, Lars [1 ]
机构
[1] Autonomous Univ Baja California, Blvd Benito Juarez S-N,Parcela 44, Mexicali 21280, Baja California, Mexico
关键词
Optoelectronic signal processing; Multivariate outlier analysis; Artificial intelligence regression; 3D measurement; DESIGN;
D O I
10.1007/s11082-016-0680-1
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper presents a technical research of an opto-mechanical system for 3D measurement. The system scanning technology is based on a mechanical rotary mirror and the computational processing of an optoelectronic signal, with application in structural health monitoring. The system has been enhanced by multivariate outlier mining and regression feedback. Multivariate outlier analysis has been implemented to detection and removal of atypical values, in order to contribute to the accuracy improvement of artificial intelligence regression algorithms. The regression of error data has been used for the correction of the 3D measurements error. New research performed in the signal and data processing of the 3D measurement system demonstrated the effectiveness of signal processing strategies as a tool for a feedback loop in any measurement system.
引用
收藏
页数:21
相关论文
共 35 条
[1]  
Acuna E., 2004, METAANALYSIS STUDY O
[2]  
[Anonymous], 2014, CENGAGE LEARNING
[3]  
[Anonymous], 1992, An Introduction to Generalized Linear Models, DOI [DOI 10.2307/1269239, 10.2307/1269239]
[4]  
[Anonymous], 1995, SAS C P SAS US GROUP
[5]   Optical 3D laser measurement system for navigation of autonomous mobile robot [J].
Basaca-Preciado, Luis C. ;
Sergiyenko, Oleg Yu. ;
Rodriguez-Quinonez, Julio C. ;
Garcia, Xochitl ;
Tyrsa, Vera V. ;
Rivas-Lopez, Moises ;
Hernandez-Balbuena, Daniel ;
Mercorelli, Paolo ;
Podrygalo, Mikhail ;
Gurko, Alexander ;
Tabakova, Irina ;
Starostenko, Oleg .
OPTICS AND LASERS IN ENGINEERING, 2014, 54 :159-169
[6]   Design and calibration of an opto-mechanical appliance for 3D non-contact orthopedic measurements - Part I: Mathematical model and laboratory prototype [J].
Caracciolo, R ;
Trevisani, A .
JOURNAL OF INTELLIGENT & ROBOTIC SYSTEMS, 2003, 36 (01) :1-21
[7]  
Carroll SusanRovezzi., 2002, STAT MADE SIMPLE SCH
[8]  
COOK RD, 1990, J AM STAT ASSOC, V85, P640, DOI 10.2307/2289996
[9]   Industrial Age non-destructive evaluation to Information Age structural health monitoring [J].
Derriso, Mark M. ;
DeSimio, Martin P. ;
McCurry, Charles D. ;
Kabban, Christine M. Schubert ;
Olson, Steven E. .
STRUCTURAL HEALTH MONITORING-AN INTERNATIONAL JOURNAL, 2014, 13 (06) :591-600
[10]   Multivariate outlier detection in exploration geochemistry [J].
Filzmoser, P ;
Garrett, RG ;
Reimann, C .
COMPUTERS & GEOSCIENCES, 2005, 31 (05) :579-587