Application of a fluorescence sensor for miniscale on-line monitoring of powder mixing kinetics

被引:32
作者
Lai, CK [1 ]
Cooney, CC [1 ]
机构
[1] MIT, Dept Chem Engn, Cambridge, MA 02139 USA
关键词
light-induced fluorescence; on-line; noninvasive; blend homogeneity; blend stability; pharmaceuticals; powders;
D O I
10.1002/jps.10478
中图分类号
R914 [药物化学];
学科分类号
100701 ;
摘要
A portable system using light-induced fluorescence technology (LIF) was development as an analytical tool for on-line monitoring of various manufacturing process applications. The LIF system was verified in several laboratory scale process applications specifically in noninvasive real-time observations of blend kinetics in tumbler blenders. This technology, through careful selection of filters for specific formulations, can provide clean and unadulterated raw data that shows the actual blend characteristic behavior of powder mixtures such as homogeneity end point and blend stability. Consistent blend homogeneity end point was demonstrated for all runs with LIF where data were verified by thief sampling and UV spectrophotometric assays. A correlation between LIF signal and drug powder concentration was established with limits of detection below 0.02% w/w for the API, Triamterene. (C) 2004Wiley-Liss, Inc. and the American Pharmacists Association.
引用
收藏
页码:60 / 70
页数:11
相关论文
共 24 条
[1]  
Allen T., 1990, PARTICLE SIZE MEASUR, VFourth
[2]  
ALLEN T, 1981, PARTICLE SIZE MEASUR, P5
[3]   Unit dose sampling: A tale of two thieves [J].
Berman, J ;
Schoeneman, A ;
Shelton, JT .
DRUG DEVELOPMENT AND INDUSTRIAL PHARMACY, 1996, 22 (11) :1121-1132
[4]   FUNDAMENTAL POWDER MIXING MECHANISMS [J].
BRIDGWATER, J .
POWDER TECHNOLOGY, 1976, 15 (02) :215-236
[5]  
Brittain H. G., 2002, Pharm. Technol, V26, P67
[6]   THE MIXING OF SOLIDS IN TUMBLING MIXERS .1. [J].
CARLEYMACAULY, KW ;
DONALD, MB .
CHEMICAL ENGINEERING SCIENCE, 1962, 17 (07) :493-&
[7]   Blending validation and content uniformity of low-content, noncohesive powder blends [J].
Carstensen, JT ;
Dali, MV .
DRUG DEVELOPMENT AND INDUSTRIAL PHARMACY, 1996, 22 (04) :285-290
[8]   SAMPLING IN BLENDING VALIDATION [J].
CARSTENSEN, JT ;
RHODES, CT .
DRUG DEVELOPMENT AND INDUSTRIAL PHARMACY, 1993, 19 (20) :2699-2708
[9]   EXAMINATION OF COMPONENTS OF VARIANCE FOR A PRODUCTION SCALE, LOW-DOSE POWDER BLEND AND RESULTING TABLETS [J].
GARCIA, T ;
ELSHEIMER, B ;
TARCZYNSKI, F .
DRUG DEVELOPMENT AND INDUSTRIAL PHARMACY, 1995, 21 (18) :2035-2045
[10]  
HARWOOD CF, 1973, ACS DIV ORG COATINGS, V33, P508