Analysis of micromixing of non-Newtonian fluids driven by alternating current electrothermal flow

被引:62
作者
Kunti, Golak [1 ]
Bhattacharya, Anandaroop [1 ]
Chakraborty, Suman [1 ]
机构
[1] Indian Inst Technol, Dept Mech Engn, Kharagpur 721302, W Bengal, India
关键词
Biochemical; Electrothermal; Micromixer; Micropump; Flow behavior index; Biomedical diagnostics; AC-ELECTROKINETICS; SYSTEMS; MIXER; MICROCHANNELS; NANOMATERIALS; GENERATION; ELECTRODES; THERAPY; FORCES;
D O I
10.1016/j.jnnfm.2017.06.010
中图分类号
O3 [力学];
学科分类号
08 ; 0801 ;
摘要
Biochemical applications pertaining to chip scale mixing often deal with fluids which exhibit non-Newtonian behavior. This paper presents numerical investigations on the characterization of the effect of shear dependent apparent viscosity of non-Newtonian fluids on the mixing efficiency and volume flow rate in an alternating current electrothermal micromixer driven by electrothermal micropump. The micromixer consists of thin film asymmetric pairs of electrodes on a microgrooved channel floor and an array of electrode pairs on the top wall. The results show that mixing quality and flow rate have a strong dependence on shear dependent viscosity of the non-Newtonian fluid. Using a power law based constitutive model, it is found that for specific design parameters, more uniform and homogeneous mixing is achieved with increasing flow behavior index. Thus, electrothermal mixing in a microfluidic device has higher efficiency and effectiveness in the regime of dilatant fluids compared to Newtonian and pseudo plastic fluids. Our results also demonstrate that an optimal voltage for maximum mixing efficiency progressively reduces, while the flow rate continues to increase monotonically, with enhancements in the applied AC potential. These results hold practical implications in several emerging applications, including chemical analysis of biological fluids in general, and biomedical diagnostics in particular. (C) 2017 Elsevier B.V. All rights reserved.
引用
收藏
页码:123 / 131
页数:9
相关论文
共 48 条
  • [11] Numerical analysis of mixing by electrothermal induced flow in microfluidic systems
    Feng, J. J.
    Krishnamoorthy, S.
    Sundaram, S.
    [J]. BIOMICROFLUIDICS, 2007, 1 (02)
  • [12] Effect of the crossing-structure sequence on mixing performance within three-dimensional micromixers
    Feng, Xiangsong
    Ren, Yukun
    Jiang, Hongyuan
    [J]. BIOMICROFLUIDICS, 2014, 8 (03):
  • [13] Novel microfluidic mixer utilizing electrokinetic driving forces under low switching frequency
    Fu, LM
    Yang, RJ
    Lin, CH
    Chien, YS
    [J]. ELECTROPHORESIS, 2005, 26 (09) : 1814 - 1824
  • [14] Electrothermal flows generated by alternating and rotating electric fields in microsystems
    Gonzalez, A.
    Ramos, A.
    Morgan, H.
    Green, N. G.
    Castellanos, A.
    [J]. JOURNAL OF FLUID MECHANICS, 2006, 564 : 415 - 433
  • [15] Hansen T.S., 2004, SIMULATION TESTING A
  • [16] Numerical simulation of AC electrothermal micropump using a fully coupled model
    Hong, F. J.
    Bai, F.
    Cheng, P.
    [J]. MICROFLUIDICS AND NANOFLUIDICS, 2012, 13 (03) : 411 - 420
  • [17] Study of Active Micromixer Driven by Electrothermal Force
    Huang, Kuan-Rong
    Chang, Jeng-Shian
    Chao, Sheng D.
    Wung, Tzong-Shyan
    Wu, Kuang-Chong
    [J]. JAPANESE JOURNAL OF APPLIED PHYSICS, 2012, 51 (04)
  • [18] Generation of solution and surface gradients using microfluidic systems
    Jeon, NL
    Dertinger, SKW
    Chiu, DT
    Choi, IS
    Stroock, AD
    Whitesides, GM
    [J]. LANGMUIR, 2000, 16 (22) : 8311 - 8316
  • [19] Rapid microfluidic mixing
    Johnson, TJ
    Ross, D
    Locascio, LE
    [J]. ANALYTICAL CHEMISTRY, 2002, 74 (01) : 45 - 51
  • [20] Rapid mixing with high-throughput in a semi-active semi-passive micromixer
    Kunti, Golak
    Bhattacharya, Anandaroop
    Chakraborty, Suman
    [J]. ELECTROPHORESIS, 2017, 38 (9-10) : 1310 - 1317