Uranium analysis in urine by inductively coupled plasma dynamic reaction cell mass spectrometry

被引:47
作者
Ejnik, JW
Todorov, TI
Mullick, FG
Squibb, K
McDiarmid, MA
Centeno, JA
机构
[1] Armed Forces Inst Pathol, Dept Environm & Toxicol Pathol, Div Biophys Toxicol, Washington, DC 20306 USA
[2] No Michigan Univ, Dept Chem, Marquette, MI 49855 USA
[3] Univ Maryland, Sch Med, Baltimore, MD 21201 USA
关键词
depleted uranium; ICP-MS; isotopes; DRC; urine;
D O I
10.1007/s00216-005-3173-9
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Urine uranium concentrations are the best biological indicator for identifying exposure to depleted uranium (DU). Internal exposure to DU causes an increased amount of urine uranium and a decreased ratio of U-235/U-238 in urine samples, resulting in measurements that vary between 0.00725 and 0.002 (i.e., natural and depleted uranium's U-235/U-238 ratios, respectively). A method based on inductively coupled plasma dynamic reaction cell mass spectrometry (ICP-DRC-MS) was utilized to identify DU in urine by measuring the quantity of total U and the U-235/U-238 ratio. The quantitative analysis was achieved using U-233 as an internal standard. The analysis was performed both with and without the reaction gas oxygen. The reaction gas converted ionized U-235(+) and U-238(+) into (UO2+)-U-235 (m/z = 267) and (UO2+)-U-238 (m/z= 270). This conversion was determined to be over 90% efficient. A polyatomic interference at m/z 234.8 was successfully removed from the U-235 signal under either DRC operating conditions (with or without oxygen as a reaction gas). The method was validated with 15 urine samples of known uranium compositions. The method detection limit for quantification was determined to be 0.1 pg U mL(-1) urine and an average coefficient of variation (CV) of 1-2% within the sample measurements. The method detection limit for determining U-235/U-238 ratio was 3.0 pg U mL(-1) urine. An additional 21 patient samples were analyzed with no information about medical history. The measured U-235/U-238 ratio within the urine samples correctly identified the presence or absence of internal DU exposure in all 21 patients.
引用
收藏
页码:73 / 79
页数:7
相关论文
共 44 条
[1]  
AEPI, 1995, HLTH ENV CONS DEPL U
[2]   INVESTIGATION OF THE DIRECT DETERMINATION OF URANIUM IN PLASMA AND URINE BY INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY [J].
ALLAIN, P ;
BERRE, S ;
PREMELCABIC, A ;
MAURAS, Y ;
DELAPORTE, T ;
COURNOT, A .
ANALYTICA CHIMICA ACTA, 1991, 251 (1-2) :183-185
[3]   Applications of inductively coupled plasma mass spectrometry and laser ablation inductively coupled plasma mass spectrometry in materials science [J].
Becker, JS .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2002, 57 (12) :1805-1820
[4]   Isotopic analysis of uranium and plutonium using ICP-MS and estimation of burn-up of spent uranium in contaminated environmental samples [J].
Boulyga, SF ;
Becker, JS .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2002, 17 (09) :1143-1147
[5]   Determination of 236U/238U isotope ratio in contaminated environmental samples using different ICP-MS instruments [J].
Boulyga, SF ;
Matusevich, JL ;
Mironov, VP ;
Kudrjashov, VP ;
Halicz, L ;
Segal, I ;
McLean, JA ;
Montaser, A ;
Becker, JS .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2002, 17 (08) :958-964
[6]   Optimisation and application of ICP-MS and alpha-spectrometry for determination of isotopic ratios of depleted uranium and plutonium in samples collected in Kosovo [J].
Boulyga, SF ;
Testa, C ;
Desideri, D ;
Becker, JS .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2001, 16 (11) :1283-1289
[7]   DIRECT DETECTION OF TRACE LEVELS OF URANIUM BY LASER-INDUCED KINETIC PHOSPHORIMETRY [J].
BRINA, R ;
MILLER, AG .
ANALYTICAL CHEMISTRY, 1992, 64 (13) :1413-1418
[8]   Determination of uranium in urine by inductively coupled plasma mass spectrometry with pneumatic nebulization [J].
Caddia, M ;
Iversen, BS .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1998, 13 (04) :309-313
[9]   THE DETERMINATION OF URANIUM IN NATURAL-WATERS AT PPB LEVELS BY THIN-FILM X-RAY-FLUORESCENCE SPECTROMETRY AFTER COPRECIPITATION WITH AN IRON DIBENZYLDITHIOCARBAMATE CARRIER COMPLEX [J].
CARAVAJAL, GS ;
MAHAN, KI ;
LEYDEN, DE .
ANALYTICA CHIMICA ACTA, 1982, 135 (02) :205-214
[10]  
DANG H S, 1992, Health Physics, V62, P562, DOI 10.1097/00004032-199206000-00010