Enhanced Electrochemical Determination of Catechol and Hydroquinone Based on Pd Nanoparticles/Poly(Taurine) Modified Glassy Carbon Electrode

被引:23
作者
Kocak, Cagri Ceylan [1 ]
Kocak, Suleyman [2 ]
机构
[1] Dokuz Eylul Univ, Bergama Vocat Sch, TR-35700 Izmir, Turkey
[2] Manisa Celal Bayar Univ, Sci & Art Fac, Dept Chem, TR-45040 Manisa, Turkey
关键词
poly(taurine); Pd nanoparticle; hydroquinone and catechol; simultaneous determination; VOLTAMMETRIC DETERMINATION; SENSITIVE DETERMINATION; PASTE ELECTRODE; ASCORBIC-ACID; URIC-ACID; NANOPARTICLES; GOLD; SENSOR; ELECTROOXIDATION; FABRICATION;
D O I
10.1002/elan.201900500
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Here, Pd nanoparticles and poly(taurine) film was prepared on the glassy carbon electrode surface (Pd/Poly(TAU)/GCE) by the rapid electrochemical technique. The proposed composite surface was characterized by scanning electron microscopy(SEM), X-ray photoelectron spectroscopy(XPS) and electrochemical impedance spectroscopy(EIS). Enhanced electron transfer ability and higher electroactive surface area were achieved at Pd/Poly (TAU)/GCE as compared to the bare GCE and polymer film electrode. The new and highly stable Pd/Poly(TAU)/GCE was employed for the individual and simultaneous determination of hydroquinone and catechol which were environmentally toxic. Under the optimized conditions, HQ and CC were individually determined by using the differantial pulse voltammetry in the linear ranges of 0.008-100 mu M and 0.001-100 mu M with the detection limits of (LOD) 2.1 nM and 0.68 nM, respectively. In case of simultaneous determination, LODs were found as 10 nM and 0.88 nM for HQ and CC, respectively. The content of both analytes in the real sample analysis was evaluated in the river water and tap water successfully.
引用
收藏
页码:358 / 366
页数:9
相关论文
共 50 条
  • [11] Simultaneous Determination of Hydroquinone and Catechol Using Poly(p-aminobenzoic acid) Modified Glassy Carbon Electrode
    Yang, Ping
    Zhu, Qiyong
    Chen, Yonghong
    Wang, Fengwu
    JOURNAL OF APPLIED POLYMER SCIENCE, 2009, 113 (05) : 2881 - 2886
  • [12] Electrochemical behavior of hydroquinone and catechol at glassy carbon electrode modified by electropolymerization of tetraruthenated oxovanadium porphyrin
    Ribeiro, Gabriel H.
    Vilarinho, Luana M.
    Ramos, Thiago dos S.
    Bogado, Andre L.
    Dinelli, Luis R.
    ELECTROCHIMICA ACTA, 2015, 176 : 394 - 401
  • [13] Simultaneous determination of catechol and hydroquinone based on poly (diallyldimethylammonium chloride) functionalized graphene-modified glassy carbon electrode
    Letao Wang
    Yan Zhang
    Yongling Du
    Daban Lu
    Yuzhen Zhang
    Chunming Wang
    Journal of Solid State Electrochemistry, 2012, 16 : 1323 - 1331
  • [14] Poly(Taurine-Glutathione)/Carbon Nanotube Modified Glassy Carbon Electrode as a New Levofloxacin Sensor
    Kocak, Cagri Ceylan
    ELECTROANALYSIS, 2019, 31 (08) : 1552 - 1561
  • [15] A glassy carbon electrode modified with cerium phosphate nanotubes for the simultaneous determination of hydroquinone, catechol and resorcinol
    Li, Zhen
    Yue, Yuhua
    Hao, Yanjun
    Feng, Shun
    Zhou, Xianli
    MICROCHIMICA ACTA, 2018, 185 (04)
  • [16] Au nanoparticles/poly(caffeic acid) composite modified glassy carbon electrode for voltammetric determination of acetaminophen
    Li, Tianbao
    Xu, Juan
    Zhao, Lei
    Shen, Shaofei
    Yuan, Maosen
    Liu, Wenming
    Tu, Qin
    Yu, Ruijin
    Wang, Jinyi
    TALANTA, 2016, 159 : 356 - 364
  • [17] Simultaneous electrochemical detection of catechol and hydroquinone based on gold nanoparticles@carbon nanocages modified electrode
    Huang, Yi Hong
    Chen, Jian Hua
    Ling, Li Jing
    Su, Zhen Bo
    Sun, Xue
    Hu, Shi Rong
    Weng, Wen
    Huang, Yang
    Wu, Wen Bing
    He, Ya San
    ANALYST, 2015, 140 (23) : 7939 - 7947
  • [18] An electrochemically aminated glassy carbon electrode for simultaneous determination of hydroquinone and catechol
    Wang, Xiuyun
    Xi, Min
    Guo, Mengmeng
    Sheng, Fangmeng
    Xiao, Guang
    Wu, Shuo
    Uchiyama, Shunichi
    Matsuura, Hiroaki
    ANALYST, 2016, 141 (03) : 1077 - 1082
  • [19] Simultaneous and selective electrochemical determination of hydroquinone, catechol and resorcinol at poly(1,5-diaminonaphthalene)/glassy carbon-modified electrode in different media
    Hassan, Khalid Mahmoud
    Hathoot, Abla Ahmed
    Oura, Mohamed Fathi Abo
    Azzem, Magdi Abdel
    RSC ADVANCES, 2018, 8 (12): : 6346 - 6355
  • [20] Glassy Carbon Electrode Modified with C/Au Nanostructured Materials for Simultaneous Determination of Hydroquinone and Catechol in Water Matrices
    Pina, Samuel
    Candia-Onfray, Christian
    Hassan, Natalia
    Jara-Ulloa, Paola
    Contreras, David
    Salazar, Ricardo
    CHEMOSENSORS, 2021, 9 (05)