Three-dimensional finite element analysis of silk protein rod implantation after core decompression for osteonecrosis of the femoral head

被引:10
|
作者
Huang, Liangta [1 ]
Chen, Feiyan [2 ]
Wang, Siqun [2 ]
Wei, Yibing [2 ]
Huang, Gangyong [2 ]
Chen, Jie [2 ]
Shi, Jingsheng [2 ]
Naidu, Rajeev K. [3 ]
Xia, Jun [2 ]
Tao, Tiger H. [4 ]
机构
[1] Fudan Univ, Peoples Hosp 5, Dept Orthoped, Shanghai, Peoples R China
[2] Fudan Univ, Huashan Hosp, Dept Orthoped, Shanghai 200040, Peoples R China
[3] Univ Sydney, Sch Med, Camperdown, NSW, Australia
[4] Chinese Acad Sci, Shanghai Inst Microsyst & Informat Technol, State Key Lab Transducer Technol, Shanghai, Peoples R China
关键词
Silk protein rod; Osteonecrosis; 3D finite element analyses; BONE; FIBROIN;
D O I
10.1186/s12891-019-2914-4
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background Several methods are available for the treatment of early-stage osteonecrosis of the femoral head. Core decompression with implantation is a widely-used treatment. However, no single implant is recognized as the most effective way to prevent disease progression. Silk has high strength and resiliency. This study explored the possibility of a strong and resilient silk protein biomaterial as a new alternative implant. Methods We investigated the biomechanical properties of the silk protein material by regular compression, torsion, and three-point bending tests. We established three-dimensional finite element models of different degrees of femoral head osteonecrosis following simple core decompression, fibula implantation, porous tantalum rod implantation, and silk protein rod implantation. Finally, we compared the differences in displacement and surface stress under load at the femoral head weight-bearing areas between these models. Results The elastic modulus and shear modulus of the silk protein material was 0.49GPa and 0.66GPa, respectively. Three-dimensional finite element analyses demonstrated less displacement and surface stress at the femoral head weight-bearing areas following silk protein rod implantation compared to simple core decompression (p < 0.05), regardless of the extent of osteonecrosis. No differences were noted in the surface deformation or surface stress of the femoral head weight-bearing areas following silk protein rod, fibula or tantalum rod implantation (p > 0.05). Conclusions When compared with simple core decompression, silk protein rod implantation demonstrated less displacement and surface stress at the femoral head weight-bearing area, but more than fibula or tantalum rod implantation. Similar effects on the surface stress of the femoral head between the silk rod, fibula and tantalum rod implantations, combined with additional modifiable properties support the use of silk protein as a suitable biomaterial in osteonecrosis surgery.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Three-dimensional finite element analysis of silk protein rod implantation after core decompression for osteonecrosis of the femoral head
    Liangta Huang
    Feiyan Chen
    Siqun Wang
    Yibing Wei
    Gangyong Huang
    Jie Chen
    Jingsheng Shi
    Rajeev K. Naidu
    Jun Xia
    Tiger H. Tao
    BMC Musculoskeletal Disorders, 20
  • [2] Core decompression and osteonecrosis intervention rod in osteonecrosis of the femoral head: clinical outcome and finite element analysis
    Floerkemeier, Thilo
    Lutz, Andre
    Nackenhorst, Udo
    Thorey, Fritz
    Waizy, Hazibullah
    Windhagen, Henning
    von Lewinski, Gabriela
    INTERNATIONAL ORTHOPAEDICS, 2011, 35 (10) : 1461 - 1466
  • [3] Mechanics of femoral head osteonecrosis using three-dimensional finite element method
    Yang, JW
    Koo, KH
    Lee, MC
    Yang, P
    Noh, MD
    Kim, SY
    Kim, KI
    Ha, YC
    Joun, MS
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2002, 122 (02) : 88 - 92
  • [4] Failure after core decompression in osteonecrosis of the femoral head
    Taek Rim Yoon
    Eun Kyoo Song
    Sung Man Rowe
    Chol Hong Park
    International Orthopaedics, 2001, 24 : 316 - 318
  • [5] Clinical outcome and survivorship analysis of core decompression for early osteonecrosis of the femoral head
    Iorio, R
    Healy, WL
    Abramowitz, AJ
    Pfeifer, BA
    JOURNAL OF ARTHROPLASTY, 1998, 13 (01) : 34 - 41
  • [6] Three-dimensional finite element analysis on cochlear implantation electrode insertion
    Ren, Liu-Jie
    Yu, Yi
    Zhang, Yu-Heng
    Liu, Xin-Dong
    Sun, Zeng-Jun
    Yao, Wen-Juan
    Zhang, Tian-Yu
    Wang, Cheng
    Li, Chen-Long
    BIOMECHANICS AND MODELING IN MECHANOBIOLOGY, 2023, 22 (02) : 467 - 478
  • [7] Treatment of nontraumatic osteonecrosis of the femoral head with the implantation of core decompression and concentrated autologous bone marrow containing mononuclear cells
    Bai-Liang Wang
    Wei Sun
    Zhen-Cai Shi
    Nian-Fei Zhang
    De-Bo Yue
    Wan-Shou Guo
    Shu-Qing Xu
    Jin-Ning Lou
    Zi-Rong Li
    Archives of Orthopaedic and Trauma Surgery, 2010, 130 : 859 - 865
  • [8] Treatment of nontraumatic osteonecrosis of the femoral head with the implantation of core decompression and concentrated autologous bone marrow containing mononuclear cells
    Wang, Bai-Liang
    Sun, Wei
    Shi, Zhen-Cai
    Zhang, Nian-Fei
    Yue, De-Bo
    Guo, Wan-Shou
    Xu, Shu-Qing
    Lou, Jin-Ning
    Li, Zi-Rong
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2010, 130 (07) : 859 - 865
  • [9] Three-dimensional finite element analysis for best angles of dog canine teeth implantation
    Zhou, Ziyao
    Zhang, Huimin
    Ren, Yuxin
    Zhou, Xiaoxiao
    Liu, Haifeng
    Zhong, Zhijun
    Peng, Guangneng
    Cheng, Jianguo
    Zheng, Chengli
    THAI JOURNAL OF VETERINARY MEDICINE, 2022, 52 (04): : 721 - 726
  • [10] Core decompression versus other joint preserving treatments for osteonecrosis of the femoral head: a meta-analysis
    Sadile, Francesco
    Bernasconi, Alessio
    Russo, Sergio
    Maffulli, Nicola
    BRITISH MEDICAL BULLETIN, 2016, 118 (01) : 35 - 51