Frequency-Dependent Criterion for Mitigation of Transmission-Line Effects in a High-Frequency Distributed Power Systems

被引:0
|
作者
Gupta, A. [1 ]
Kumar, N. [1 ]
Mazumder, S. K. [1 ]
机构
[1] Univ Illinois, Dept Elect & Comp Engn, Chicago, IL USA
关键词
Transmission-line effect; characteristic impedance; high-frequency power transfer; distributed power system;
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
A frequency-dependent criterion that enables transfer of power at high frequency (HF) over a distributed power system (DPS) is outlined. Such a DPS can encompass conventional applications such smart building, electric vehicles, lighting and telecommunication applications, microgrid, or even distributed multi-axis motor drives or motor drives with wide separation between inverter and motor. Historically, HF DPSs for suitable applications have demonstrated compact solution of the overall power system while ensuring enhanced efficiency and reliability. However, for several such applications Achilles hill has been the transmission-line (TL) effect that a power signal encounters as it propagates through the TL. Solutions to this core problem have primarily focused on adjusting the TL length or using active compensation. While the former is primarily limited to PCB level implementations, the latter leads to high expense and complexity of the DPS. In this paper, we demonstrate a frequency-dependent criterion, which if satisfied, mitigates the TL effect and is scalable for systems that have one or more sources and singular or plurality of application load(s).
引用
收藏
页码:4624 / 4631
页数:8
相关论文
共 50 条
  • [21] FREQUENCY-DEPENDENT POLARIZATION ANALYSIS OF HIGH-FREQUENCY SEISMOGRAMS
    PARK, J
    VERNON, FL
    LINDBERG, CR
    JOURNAL OF GEOPHYSICAL RESEARCH-SOLID EARTH AND PLANETS, 1987, 92 (B12): : 12664 - 12674
  • [22] RESONATOR BASED ON A TRANSMISSION-LINE SEGMENT IN A HIGH-FREQUENCY SQUID.
    Krysanov, V.A.
    Moscow University Physics Bulletin (English Translation of Vestnik Moskovskogo Universiteta, Fizika), 1985, 40 (04): : 59 - 62
  • [23] High-frequency compensation of frequency-dependent negative resistance
    Taki, M
    Hayahara, E
    ELECTRONICS AND COMMUNICATIONS IN JAPAN PART III-FUNDAMENTAL ELECTRONIC SCIENCE, 1995, 78 (07): : 58 - 64
  • [24] TIME DOMAIN MODELING OF FREQUENCY-DEPENDENT 3-PHASE TRANSMISSION-LINE IMPEDANCE
    SEMLYEN, A
    DERI, A
    IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1985, 104 (06): : 1549 - 1555
  • [25] Validation of frequency-dependent transmission line models
    Gustavsen, B
    IEEE TRANSACTIONS ON POWER DELIVERY, 2005, 20 (02) : 925 - 933
  • [26] HIGH-FREQUENCY POWER TRANSMISSION BY LUMPED CONSTANT CIRCUIT REPLACED DISTRIBUTED CONSTANT LINE
    KAWAHARA, T
    SHIMIZU, T
    SHIOYA, M
    KIMURA, G
    IECON 89, VOLS 1-4: POWER ELECTRONICS - SIGNAL-PROCESSING & SIGNAL CONTROL - FACTORY AUTOMATION, EMERGING TECHNOLOGIES, 1989, : 77 - 81
  • [27] METHOD FOR CALCULATING HIGH-FREQUENCY INTERFERENCE ON TRANSMISSION-LINE CONDUCTORS DURING CORONA
    ZAKHARIT.MK
    ELECTRICAL TECHNOLOGY, 1971, 3 : 34 - &
  • [28] INTERACTION OF HIGH-FREQUENCY CURRENT WITH RESONANT MODE OF MAGNETOSTATIC WAVE IN TRANSMISSION-LINE
    GRECHUSHKIN, KV
    SHARAEVSKII, YP
    RADIOTEKHNIKA I ELEKTRONIKA, 1994, 39 (06): : 1017 - 1021
  • [29] A transmission line model for high-frequency power line communication channel
    Meng, H
    Chen, S
    Guan, YL
    Law, CL
    So, PL
    Gunawan, E
    Lie, TT
    POWERCON 2002: INTERNATIONAL CONFERENCE ON POWER SYSTEM TECHNOLOGY, VOLS 1-4, PROCEEDINGS, 2002, : 1290 - 1295
  • [30] HIGH-FREQUENCY TRANSMISSION-LINE MODELS FOR A THIN WIRE ABOVE A CONDUCTING GROUND
    OLYSLAGER, F
    DEZUTTER, D
    IEEE TRANSACTIONS ON ELECTROMAGNETIC COMPATIBILITY, 1995, 37 (02) : 234 - 240