Combined intacs and posterior chamber toric Implantable collamer lens implantation for keratoconic patients with extreme myopia

被引:49
作者
Coskunseven, Efekan
Onder, Methiye
Kymionis, George D. [1 ]
Diakonis, Vasilios F.
Arslan, Ebru
Tsiklis, Nikolaos
Bouzoukis, Dimitrios I.
Pallikaris, Ioannis
机构
[1] Dunya Eye Hosp, Istanbul, Turkey
[2] Univ Crete, Inst Vis & Opt, Crete, NE USA
关键词
D O I
10.1016/j.ajo.2007.05.035
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To evaluate the results of combined Intacs (Addition Technology, Fremont, California, USA) and posterior chamber toric implantable Collamer lens [ICLs] (Visian ICL; STAAR Surgical, Monrovia, California, USA) implantation in keratoconic patients with extreme myopia and irregular astigmatism. DESIGN: Prospective, single-center, noncomparative, interventional, consecutive case series. METHODS: Three eyes of two consecutive highly myopic keratoconic patients who had undergone posterior chamber toric ICLs implantation after Intacs implantation. Implantation of posterior chamber toric ICLs was performed at intervals between six and 10 months after Intacs implantation. Uncorrected visual acuity (UCVA), best spectacle,corrected visual acuity (BSCVA), refraction, topographic findings, adverse events, and postoperative complications were noted. RESULTS: No intraoperative or postoperative compli,cations were observed. An improvement in UCVA and BSCVA was found after the Intacs and toric Visian ICL procedures in all eyes. All eyes were emmetropic within 1 diopter (D), whereas the mean manifest refractive spherical equivalent refraction reduced from -18.50 +/- 2.61 D (range, -16.75 to -21.50 D) to 0.42 D (range, piano to -0.75 D). The mean difference between preoperative and last follow-up UCVA and BSCA was a gain of 6.67 +/- 1.15 lines (range, gain of six to eight lines) and 4.33 +/- 2.52 lines (range, gain of two to seven lines), respectively. CONCLUSIONS: Combined Intacs and posterior chamber toric phakic Visian ICL implantation in a two-step procedure is an effective method for correcting keratoconic patients with extreme myopia.
引用
收藏
页码:387 / 389
页数:3
相关论文
共 6 条
[1]   Intracorneal ring segments for keratoconus correction:: Long-term follow-up [J].
Alio, Jorge L. ;
Shabayek, Mohamed H. ;
Artola, Alberto .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2006, 32 (06) :978-985
[2]   Implantation of Intacs and a refractive intraocular lens to correct keratoconus [J].
Colin, J ;
Velou, S .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2003, 29 (04) :832-834
[3]   Intacs insertion with the femtosecond laser for the management of keratoconus - One-year results [J].
Ertan, Aylin ;
Kamburoglu, Gunhal ;
Bahadir, Mehmet .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2006, 32 (12) :2039-2042
[4]   Long-term follow-up of intacs for post-LASIK corneal ectasia [J].
Kymionis, George D. ;
Tsiklis, Nikolaos S. ;
Pallikaris, Aristofanis I. ;
Kounis, George ;
Diakonis, Vasilios F. ;
Astyrakakis, Nikolaos ;
Siganos, Charalambos S. .
OPHTHALMOLOGY, 2006, 113 (11) :1909-1917
[5]   Keratoconus managed with intacs - One year results [J].
Levinger, S ;
Pokroy, R .
ARCHIVES OF OPHTHALMOLOGY, 2005, 123 (10) :1308-1314
[6]   Comparison of single-segment and double-segment intacs for keratoconus and post-LASIK ectasia [J].
Sharma, Munish ;
Wachler, Brian S. Boxer .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2006, 141 (05) :891-895