HPLC-MS/MS methods for the quantitative analysis of ophthalmic acid in rodent plasma and hepatic cell line culture medium

被引:13
|
作者
Geenen, Suzanne [1 ,2 ,3 ]
Michopoulos, Filippos [1 ]
Kenna, J. Gerry [4 ]
Kolaja, Kyle L. [5 ]
Westerhoff, Hans V. [2 ,3 ]
Wilson, Ian [1 ]
机构
[1] AstraZeneca, Dept Clin Pharmacol Drug Metab & Pharmacokinet, Macclesfield SK10 4TG, Cheshire, England
[2] Univ Manchester, Manchester Ctr Integrat Syst Biol, Manchester M1 7DN, Lancs, England
[3] Univ Manchester, Doctoral Training Ctr ISBML, Manchester Interdisciplinary Bioctr, Manchester M1 7DN, Lancs, England
[4] AstraZeneca, Mol Toxicol, Global Safety Assessment, Macclesfield SK10 4TG, Cheshire, England
[5] Hoffmann La Roche Inc, Nonclin Safety NCS, Predict Toxicol Screens & Emerging Technol, Nutley, NJ 07110 USA
基金
英国工程与自然科学研究理事会; 英国生物技术与生命科学研究理事会;
关键词
Oxidative stress; Biomarkers; Hepatotoxicity; Ophthalmic acid; Glutathione; HPLC-MS/MS; INDUCED HEPATOTOXICITY; METHAPYRILENE; GLUTATHIONE; LIVER; TOXICITY; RATS;
D O I
10.1016/j.jpba.2010.11.038
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Ophthalmic acid (OA), an endogenous tripeptide analogue of glutathione, has been suggested as a potential biomarker for paracetamol/acetaminophen hepatotoxicity. Here HPLC-MS/MS methods have been developed for the precise, sensitive and specific detection and quantification of OA in in vitro cell culture medium and plasma. For the cell culture medium the LLOQ was found to be 1 ng/ml, with less than 1% between sample carry over at all concentrations and precision below 15% for within day and below 9% for between day analyses. For rat plasma the presence of endogenous OA resulted in the LLOQ being 25 ng/ml (defined as the lowest concentration on the calibration curve where the base peak was less than 20% of the LLOQ). For the plasma assay the percentage carry over was less than 1% for all concentrations and within and between batch precision was below 21%. The methods were linear for both sample types from the LLOQ up to 5 mu g/ml. The method was successfully applied to the determination of OA in samples obtained following the chronic administration of the rat hepatotoxin methapyrilene, where plasma OA concentrations were observed to show a weak negative correlation with those of established liver injury biomarkers such as aspartate aminotransferase (AST). (C) 2010 Elsevier B.V. All rights reserved.
引用
收藏
页码:1128 / 1135
页数:8
相关论文
共 36 条
  • [31] Large-Scale Synthesis of Isotopically Labeled 13C2-Tenuazonic Acid and Development of a Rapid HPLC-MS/MS Method for the Analysis of Tenuazonic Acid in Tomato and Pepper Products
    Lohrey, Lilia
    Marschik, Stefanie
    Cramer, Benedikt
    Humpf, Hans-Ulrich
    JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2013, 61 (01) : 114 - 120
  • [32] Analysis of glutathione in supernatants and lysates of a human proximal tubular cell line from perfusion culture upon intoxication with cadmium chloride by HPLC and LC-ESI-MS
    Hans Hahn
    Christian W. Huck
    Matthias Rainer
    Muhammad Najam-ul-Haq
    Rania Bakry
    Thomas Abberger
    Paul Jennings
    Walter Pfaller
    Günther K. Bonn
    Analytical and Bioanalytical Chemistry, 2007, 388 : 1763 - 1769
  • [33] Analysis of glutathione in supernatants and lysates of a human proximal tubular cell line from perfusion culture upon intoxication with cadmium chloride by HPLC and LC-ESI-MS
    Hahn, Hans
    Huck, Christian W.
    Rainer, Matthias
    Najam-ul-Haq, Muhammad
    Bakry, Rania
    Abberger, Thomas
    Jennings, Paul
    Pfaller, Walter
    Bonn, Gunther K.
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2007, 388 (08) : 1763 - 1769
  • [34] Metabolomic Analysis of Amino Acid and Organic Acid Profiles in Tissue From Ovarian Cancer Patients Using High-Performance Liquid Chromatography-Tandem Mass Spectrometry (HPLC-MS/MS) and Gas Chromatography-Tandem Mass Spectrometry (GC-MS/MS)
    Oh, Songjin
    Ji, Moongi
    Kim, Doo-Young
    Choi, Subin
    Kee, Yerim
    Woo, Sanghyeon
    Lee, Hyeon-Seong
    Choi, Byeongchan
    Park, Hyung-Jin
    Lee, Hae Nam
    Paik, Man-Jeong
    ANALYTICAL LETTERS, 2025, 58 (04) : 623 - 638
  • [35] Simultaneous Quantitative Analysis of Six Isothiazolinones in Water-Based Adhesive Used for Food Contact Materials by High-Performance Liquid Chromatography-Tandem Mass Spectrometry (HPLC-MS/MS)
    Zhong, Huaining
    Li, Zicheng
    Chen, Sheng
    Zeng, Ying
    Zheng, Jianguo
    Zeng, You
    Li, Dan
    MOLECULES, 2019, 24 (21):
  • [36] A green extraction method based on aqueous two-phase system for trace-level enrichment of multi-residue pesticides in traditional Chinese medicine prior to HPLC-MS/MS quantitative analysis
    Zhang, Xiao-Hua
    Li, Shi-Yu
    Zheng, Jing-Jing
    Li, Ming-Xuan
    Wu, Hua-Zhe
    Wen, Kun
    Tang, Kewen
    JOURNAL OF CHROMATOGRAPHY A, 2024, 1738