Safety and reliability of a handheld stimulator for neural monitoring during thyroid surgery

被引:7
作者
Lawson, Bradley R. [1 ,3 ,4 ]
Kamani, Dipti [1 ]
Shama, Mohamed [1 ]
Kyriazidis, Natalia [1 ]
Randolph, Gregory W. [1 ,2 ]
机构
[1] Massachusetts Eye & Ear Infirm, Div Thyroid & Parathyroid Surg, Dept Otolaryngol, Boston, MA 02114 USA
[2] Harvard Med Sch, Massachusetts Gen Hosp, Div Surg Oncol, Dept Surg, Boston, MA 02115 USA
[3] Licking Mem Hosp, Newark, OH USA
[4] Ohio State Univ, Coll Med, Dept Otolaryngol Head & Neck Surg, Columbus, OH 43210 USA
关键词
Endotracheal tube surface electrodes; Checkpoint stimulator; neural monitoring; nerve stimulator; electromyography; thyroid surgery; parathyroid surgery; RECURRENT LARYNGEAL NERVE; PARATHYROID SURGERY; IDENTIFICATION; PARALYSIS; AUDIT;
D O I
10.1002/lary.28027
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Objective The Checkpoint nerve stimulator (Checkpoint Surgical, Cleveland, OH) is a U.S. Food and Drug Administration-approved device for neural localization and monitoring during surgery. Its safety, efficacy, and reliability for neural monitoring during thyroid and parathyroid surgery have not been compared to more standard formats of neural monitoring. Study Design Retrospective review. Methods Vagal, recurrent, and superior laryngeal nerve monitoring were performed using both the Checkpoint stimulator and Medtronic NIM 3.0 laryngeal electromyography endotracheal tube (Medtronic, Jacksonville, FL) during thyroid and parathyroid surgery. A total of 21 operated sides in 15 patients were included for analysis. Latency and amplitude data for the Checkpoint stimulator were recorded using the NIM monitor and compared to normative endotracheal tube surface electrode data. Results Mean amplitude using the Checkpoint stimulator was 574.6 microvolts (mu V), 1060.6 mu V, and 182.8 mu V for the vagus, recurrent laryngeal, and superior laryngeal nerves, respectively. Mean amplitude using standard laryngeal electromyography was 709 mu V, 1077.0 mu V, and 183.7 mu V for the same nerves. Mean latency was significantly shorter with stimulation of the recurrent laryngeal nerve compared to the vagus nerve with both stimulators (P < 0.001). No neural injuries occurred during the study. Conclusion The Checkpoint stimulator is a safe and reliable alternative to traditional laryngeal electromyography providing equivalent induced electromyography of the vocalis for neural monitoring during thyroid and parathyroid surgery. Level of Evidence 4 Laryngoscope, 130:561-565, 2020
引用
收藏
页码:561 / 565
页数:5
相关论文
共 50 条
  • [41] The Role of Nerve Monitoring to Predict Postoperative Recurrent Laryngeal Nerve Function in Thyroid and Parathyroid Surgery
    Eid, Issam
    Miller, Frank R.
    Rowan, Stephanie
    Otto, Randal A.
    LARYNGOSCOPE, 2013, 123 (10) : 2583 - 2586
  • [42] Effectiveness of the recurrent laryngeal nerve monitoring during endoscopic thyroid surgery: systematic review and meta-analysis
    Liu, Yu-Chen
    Shen, Chuan-Lu
    Fu, Zi-Yue
    Zhang, Yu-Chen
    Han, Yan-Xun
    Chen, Bang-Jie
    Jiang, Yuan
    Yin, Si-Yue
    Tao, Zhi
    Sheng, Shu-Yan
    Wang, Jian-Peng
    Liang, Bing-Yu
    Zhang, Liang
    Wang, Dong
    Wu, Kai-Le
    Pan, Hai-Feng
    Liu, Ye-Hai
    INTERNATIONAL JOURNAL OF SURGERY, 2023, 109 (07) : 2070 - 2081
  • [43] Endoscopic thyroid surgery requires surgeons, patient candidacy & neural monitoring
    Sun, Hui
    Dionigi, Gianlorenzo
    INTERNATIONAL JOURNAL OF ENDOCRINE ONCOLOGY, 2018, 5 (01)
  • [44] Optimization of Intraoperative Neural Monitoring of the Recurrent Laryngeal Nerve in Thyroid Surgery
    Hsieh, Chia-Yuan
    Tan, Hao
    Huang, Hui-Fang
    Huang, Tzu-Yen
    Wu, Che-Wei
    Chang, Pi-Ying
    Lu, David-Vi
    Lu, I-Cheng
    MEDICINA-LITHUANIA, 2022, 58 (04):
  • [45] Surface Electrode Recurrent Laryngeal Nerve Monitoring During Thyroid Surgery: Normative Values
    Choby, Garret
    Hollenbeak, Christopher S.
    Johnson, Samuel
    Goldenberg, David
    JOURNAL OF CLINICAL NEUROPHYSIOLOGY, 2010, 27 (01) : 34 - 37
  • [46] The advantages and disadvantages of nerve monitoring during thyroid surgery in childhood
    Meyer, T.
    Hamelmann, W.
    Timmermann, W.
    Meyer, B.
    Hoecht, B.
    EUROPEAN JOURNAL OF PEDIATRIC SURGERY, 2006, 16 (06) : 392 - 395
  • [47] Recurrent laryngeal nerve monitoring during thyroid surgery in childhood
    Meyer, T.
    Hoecht, B.
    EUROPEAN JOURNAL OF PEDIATRIC SURGERY, 2006, 16 (03) : 149 - 154
  • [48] External laryngeal nerve in thyroid surgery: Is the nerve stimulator necessary?
    Aina, EN
    Hisham, AN
    EUROPEAN JOURNAL OF SURGERY, 2001, 167 (09) : 662 - 665
  • [49] Monitoring of the posterior cricoarytenoid muscle represents another option for neural monitoring during thyroid surgery: Normative vagal and recurrent laryngeal nerve posterior cricoarytenoid muscle electromyographic data
    Liddy, Whitney
    Barber, Samuel R.
    Lin, Brian M.
    Kamani, Dipti
    Kyriazidis, Natalia
    Lawson, Bradley
    Randolph, Gregory W.
    LARYNGOSCOPE, 2018, 128 (01) : 283 - 289
  • [50] Stimulating Dissecting Instruments During Neuromonitoring of RLN in Thyroid Surgery
    Chiang, Feng-Yu
    Lu, I-Cheng
    Chang, Pi-Ying
    Sun, Hui
    Wang, Ping
    Lu, Xiu-Bo
    Chen, Hui-Chun
    Chen, Hsiu-Ya
    Kim, Hoon Yub
    Dionigi, Gianlorenzo
    Wu, Che-Wei
    LARYNGOSCOPE, 2015, 125 (12) : 2832 - 2837