Safety and reliability of a handheld stimulator for neural monitoring during thyroid surgery

被引:7
作者
Lawson, Bradley R. [1 ,3 ,4 ]
Kamani, Dipti [1 ]
Shama, Mohamed [1 ]
Kyriazidis, Natalia [1 ]
Randolph, Gregory W. [1 ,2 ]
机构
[1] Massachusetts Eye & Ear Infirm, Div Thyroid & Parathyroid Surg, Dept Otolaryngol, Boston, MA 02114 USA
[2] Harvard Med Sch, Massachusetts Gen Hosp, Div Surg Oncol, Dept Surg, Boston, MA 02115 USA
[3] Licking Mem Hosp, Newark, OH USA
[4] Ohio State Univ, Coll Med, Dept Otolaryngol Head & Neck Surg, Columbus, OH 43210 USA
关键词
Endotracheal tube surface electrodes; Checkpoint stimulator; neural monitoring; nerve stimulator; electromyography; thyroid surgery; parathyroid surgery; RECURRENT LARYNGEAL NERVE; PARATHYROID SURGERY; IDENTIFICATION; PARALYSIS; AUDIT;
D O I
10.1002/lary.28027
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Objective The Checkpoint nerve stimulator (Checkpoint Surgical, Cleveland, OH) is a U.S. Food and Drug Administration-approved device for neural localization and monitoring during surgery. Its safety, efficacy, and reliability for neural monitoring during thyroid and parathyroid surgery have not been compared to more standard formats of neural monitoring. Study Design Retrospective review. Methods Vagal, recurrent, and superior laryngeal nerve monitoring were performed using both the Checkpoint stimulator and Medtronic NIM 3.0 laryngeal electromyography endotracheal tube (Medtronic, Jacksonville, FL) during thyroid and parathyroid surgery. A total of 21 operated sides in 15 patients were included for analysis. Latency and amplitude data for the Checkpoint stimulator were recorded using the NIM monitor and compared to normative endotracheal tube surface electrode data. Results Mean amplitude using the Checkpoint stimulator was 574.6 microvolts (mu V), 1060.6 mu V, and 182.8 mu V for the vagus, recurrent laryngeal, and superior laryngeal nerves, respectively. Mean amplitude using standard laryngeal electromyography was 709 mu V, 1077.0 mu V, and 183.7 mu V for the same nerves. Mean latency was significantly shorter with stimulation of the recurrent laryngeal nerve compared to the vagus nerve with both stimulators (P < 0.001). No neural injuries occurred during the study. Conclusion The Checkpoint stimulator is a safe and reliable alternative to traditional laryngeal electromyography providing equivalent induced electromyography of the vocalis for neural monitoring during thyroid and parathyroid surgery. Level of Evidence 4 Laryngoscope, 130:561-565, 2020
引用
收藏
页码:561 / 565
页数:5
相关论文
共 50 条
  • [1] Intraoperative neural monitoring in thyroid cancer surgery
    Randolph, Gregory W.
    Kamani, Dipti
    LANGENBECKS ARCHIVES OF SURGERY, 2014, 399 (02) : 199 - 207
  • [2] Continuous intraoperative neural monitoring in thyroid surgery: a Mexican experience
    Veronica Chavez, Karla
    Ramirez, Jackeline
    Pablo Pantoja, Juan
    Sierra, Mauricio
    Velazquez-Fernandez, David
    Herrera, Miguel F.
    UPDATES IN SURGERY, 2017, 69 (04) : 505 - 508
  • [3] Anterior laryngeal electrodes for recurrent laryngeal nerve monitoring during thyroid and parathyroid surgery: New expanded options for neural monitoring
    Liddy, Whitney
    Lawson, Bradley R.
    Barber, Samuel R.
    Kamani, Dipti
    Shama, Mohamed
    Soylu, Selen
    Wu, Che Wei
    Chiang, Feng-Yu
    Scharpf, Joseph
    Barczynski, Marcin
    Dralle, Henning
    Van Slycke, Sam
    Schneider, Rick
    Dionigi, Gianlorenzo
    Randolph, Gregory W.
    LARYNGOSCOPE, 2018, 128 (12) : 2910 - 2915
  • [4] Informed Consent for Intraoperative Neural Monitoring in Thyroid and Parathyroid Surgery - Consensus Statement of the International Neural Monitoring Study Group
    Wu, Che-Wei
    Huang, Tzu-Yen
    Randolph, Gregory W.
    Barczynski, Marcin
    Schneider, Rick
    Chiang, Feng-Yu
    Karcioglu, Amanda Silver
    Wojtczak, Beata
    Frattini, Francesco
    Gualniera, Patrizia
    Sun, Hui
    Weber, Frank
    Angelos, Peter
    Dralle, Henning
    Dionigi, Gianlorenzo
    FRONTIERS IN ENDOCRINOLOGY, 2021, 12
  • [5] Pediatric intraoperative nerve monitoring during thyroid surgery: A review from the American Head and Neck Society Endocrine Surgery Section and the International Neural Monitoring Study Group
    Diercks, Gillian R.
    Rastatter, Jeff C.
    Kazahaya, Ken
    Kamani, Dipti
    Quintanilla-Dieck, Lourdes
    Shindo, Maisie L.
    Hartnick, Christopher
    Shin, Jennifer J.
    Singer, Michael C.
    Stack, Brendan C., Jr.
    Chen, Amy Y.
    St John, Maie A.
    Scharpf, Joseph
    Agrawal, Nishant
    Jayawardena, Asitha D. L.
    Iwata, Ayaka J.
    Okose, Okenwa
    Wang, Bo
    Mcilroy, Dioan
    Cheung, Anthony
    Wu, Che Wei
    Chiang, Feng Yu
    Dionigi, Gianlorenzo
    Barczynski, Marcin
    Brauckhoff, Katrin
    Lorenz, Kerstin
    Hartl, Dana
    Tolley, Neil
    Brooks, Jennifer A.
    Schneider, Rick
    Dralle, Henning
    Abdelhamid Ahmed, Amr H.
    Randolph, Gregory W.
    HEAD AND NECK-JOURNAL FOR THE SCIENCES AND SPECIALTIES OF THE HEAD AND NECK, 2022, 44 (06): : 1468 - 1480
  • [6] Prognostic value of intraoperative neural monitoring of the recurrent laryngeal nerve in thyroid surgery
    Stopa, Malgorzata
    Barczynski, Marcin
    LANGENBECKS ARCHIVES OF SURGERY, 2017, 402 (06) : 957 - 964
  • [7] Efficacy of Transcartilaginous Electrodes for Intraoperative Neural Monitoring During Thyroid Surgery
    Jung, Seon Min
    Tae, Kyung
    Song, Chang Myeon
    Lee, Seung Hwan
    Jeong, Jin Hyeok
    Ji, Yong Bae
    CLINICAL AND EXPERIMENTAL OTORHINOLARYNGOLOGY, 2020, 13 (04) : 422 - 428
  • [8] Intraoperative nerve monitoring during thyroid surgery
    Gardner, Ivy H.
    Doherty, Gerard M.
    McAneny, David
    CURRENT OPINION IN ENDOCRINOLOGY DIABETES AND OBESITY, 2016, 23 (05) : 394 - 399
  • [9] Precision Neuromuscular Block Management for Neural Monitoring During Thyroid Surgery
    Lu, I-Cheng
    Wu, Sheng-Hua
    Chang, Pi-Ying
    Ho, Pi-Yang
    Huang, Tzu-Yen
    Lin, Yi-Chu
    Kamani, Dipti
    Randolph, Gregory W.
    Dionigi, Gianlorenzo
    Chiang, Feng-Yu
    Wu, Che-Wei
    JOURNAL OF INVESTIGATIVE SURGERY, 2021, 34 (12) : 1389 - 1396
  • [10] Safety of continuous intraoperative vagus nerve neuromonitoring during thyroid surgery
    Mathieson, Timothy
    Jimaja, Wedali
    Triponez, Frederic
    Licker, Marc
    Karenovics, Wolfram
    Makovac, Petra
    Muradbegovic, Mirza
    Belfontali, Valentina
    Bedat, Benoit
    Demarchi, Marco Stefano
    BJS OPEN, 2023, 7 (03):