Evaluation of different doses of transcutaneous nerve stimulation for pain relief during labour: a randomized controlled trial

被引:22
作者
Baez-Suarez, Anibal [1 ]
Martin-Castillo, Estela [1 ]
Garcia-Andujar, Josue [1 ]
Garcia-Hernandez, Jose Angel [1 ]
Quintana-Montesdeoca, Maria P. [1 ]
Francisco Loro-Ferrer, Juan [1 ]
机构
[1] Univ Las Palmas Gran Canaria, Dept Med & Surg Sci, Paseo Blas Cabrera Felipe S-N, Las Palmas Gran Canaria 35016, Las Palmas, Spain
关键词
Transcutaneous electrical nerve stimulation; Pain relief; Randomized controlled trial; Obstetric labour; Physical therapy modality; 1ST STAGE; TENS; MECHANISMS; ANALGESIA;
D O I
10.1186/s13063-018-3036-2
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Background: Pain during labour is one of the most intense pain that women may experience in their lifetime. There are several non-pharmacological analgesic methods to relieve pain during labour, among them transcutaneous electrical nerve stimulation (TENS). TENS is a low-frequency electrotherapy technique, analgesic type, generally used in musculoskeletal pathology, but it has also come to be used as an alternative treatment during labour. The purpose of this study is to investigate the pain-relieving effect of a TENS application during labour and to find out the most effective dose. Methods: This study is a randomized, double-blind, placebo-controlled trial. TENS therapy was initiated at the beginning of the active phase of labour. Participants were randomly assigned to three groups (21 per group: two active TENS and one placebo). Active TENS 1 intervention consisted in a constant frequency of 100-Hz, 100-mu s, active TENS 2 intervention consisted in a varying high-frequency (80-100Hz), 350 s, and in a placebo group, participants were connected to the TENS unit without electrical stimulation. TENS was applied with two self-adhesive electrodes placed parallel to the spinal cord (T10-L1 and S2-S4 levels). The primary outcome was pain intensity (0-10cm) measured on a visual analogue scale (VAS) at several stages (at baseline and at 10 and 30 min later). Secondary outcomes included women's satisfaction (via the Care in Obstetrics: Measure for Testing Satisfaction scale). Results: Sixty-three women participated. Regarding baseline characteristics, no differences were found among the three groups. The active TENS 2 group obtained an improvement with clinically significant VAS results (-2.9, 95% confidence interval -4.1 to -1.6, p<0.001). Regarding satisfaction, the results also revealed better results in the active TENS than in the placebo group. Conclusions: TENS with high frequencies modified in time as well as high pulse width are effective for relieving labour pain, and they are well considered by pregnant participants.
引用
收藏
页数:10
相关论文
共 37 条
[1]   The use of transcutaneous electrical nerve stimulation (TENS) for pain relief in labour: a review of the evidence [J].
Bedwell, Carol ;
Dowswell, Therese ;
Neilson, James P. ;
Lavender, Tina .
MIDWIFERY, 2011, 27 (05) :E141-E148
[2]   Relationship between intensity and relief in patients with acute severe pain [J].
Bernstein, SL ;
Bijur, PE ;
Gallagher, EJ .
AMERICAN JOURNAL OF EMERGENCY MEDICINE, 2006, 24 (02) :162-166
[3]   The efficacy of transcutaneous electrical nerve stimulation on the improvement of walking distance in patients with peripheral arterial disease with intermittent claudication: study protocol for a randomised controlled trial: the TENS-PAD study [J].
Besnier, Florent ;
Senard, Jean-Michel ;
Gremeaux, Vincent ;
Riedel, Melanie ;
Garrigues, Damien ;
Guiraud, Thibaut ;
Labrunee, Marc .
TRIALS, 2017, 18
[4]   Transcutaneous electrical nerve stimulation (TENS) can reduce postoperative analgesic consumption. A meta-analysis with assessment of optimal treatment parameters for postoperative pain [J].
Bjordal, JM ;
Johnson, MI ;
Ljunggreen, AE .
EUROPEAN JOURNAL OF PAIN, 2003, 7 (02) :181-188
[5]  
Bloodworth DM, 2004, AM J PHYS MED REHAB, V83, P584, DOI [10.1097/01.PHM.0000133439.28817.51, 10.1097/01.phm.0000133439.28817.51]
[6]   Maternal experience of musculoskeletal pain during pregnancy and birth outcomes: Significance of lower back and pelvic pain [J].
Brown, A. ;
Johnston, R. .
MIDWIFERY, 2013, 29 (12) :1346-1351
[7]   PAIN RELIEF IN LABOR BY TRANS-CUTANEOUS ELECTRICAL NERVE-STIMULATION - TESTING OF A MODIFIED STIMULATION TECHNIQUE AND EVALUATION OF THE NEUROLOGICAL AND BIOCHEMICAL CONDITION OF THE NEWBORN-INFANT [J].
BUNDSEN, P ;
ERICSON, K ;
PETERSON, LE ;
THIRINGER, K .
ACTA OBSTETRICIA ET GYNECOLOGICA SCANDINAVICA, 1982, 61 (02) :129-136
[8]   Transcutaneous electrical nerve stimulation in labour pain: A systematic review [J].
Carroll, D ;
Tramer, M ;
McQuay, H ;
Nye, B ;
Moore, A .
BRITISH JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 1997, 104 (02) :169-175
[9]   Pain relief by applying transcutaneous electrical nerve stimulation (TENS) on acupuncture points during the first stage of labor: A randomized double-blind placebo-controlled trial [J].
Chao, An-Shine ;
Chao, Angel ;
Wang, Tzu-Hao ;
Chang, Yu-Cheng ;
Peng, Hsiu-Huei ;
Chang, Shuenn-Dyh ;
Chao, Anne ;
Chang, Chee-Jen ;
Lai, Chyong-Huey ;
Wong, Alice M. K. .
PAIN, 2007, 127 (03) :214-220
[10]   An Investigation Into the Effects of Frequency-Modulated Transcutaneous Electrical Nerve Stimulation (TENS) on Experimentally-Induced Pressure Pain in Healthy Human Participants [J].
Chen, Chih-Chung ;
Johnson, Mark I. .
JOURNAL OF PAIN, 2009, 10 (10) :1029-1037