Do current dual chamber cardioverter defibrillators have advantages over conventional single chamber cardioverter defibrillators in reducing inappropriate therapies? A randomized, prospective study

被引:121
作者
Deisenhofer, I
Kolb, C
Ndrepepa, G
Schreieck, J
Karch, M
Schmieder, S
Zrenner, B
Schmitt, C
机构
[1] Deutsch Herzzentrum Munchen, D-80636 Munich, Germany
[2] Tech Univ Munich, Klinikum Rechts Isar, Med Klin 1, D-8000 Munich, Germany
关键词
dual chamber implantable cardioverter defibrillator; detection algorithm; inappropriate therapy; atrial fibrillation;
D O I
10.1046/j.1540-8167.2001.00134.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Dual Chamber vs Single Chamber Cardioverter Defibrillators. Introduction: Supraventricular tachyarrhythmias are the main cause of inappropriate therapies in patients with conventional single chamber implantable cardioverter defibrillators (VVI-ICD). It was anticipated that dual chamber cardioverter defibrillators (DDD-ICD), with their capacity to analyze atrial and ventricular rhythm, could substantially reduce inappropriate therapies. Methods and Results: Our prospective study included 92 patients (87 men; mean age 61 +/- 12.7 years) who were randomly assigned to a VVI-ICD (45 patients) or a DDD-ICD (47 patients). Both groups were followed for 7.5 +/- 3.5 and 7.6 +/- 4.1 months, respectively, During the follow-up period, overall 725 ventricular tachycardia (VT)/ventricular fibrillation (VF) episodes were recorded in 45 (49%) of 92 patients. Of these episodes, 404 (56%) occurred in the VVI-ICD group and 321 (44%) episodes occurred in the DDD-ICD group. Twenty-three (51%) patients in the VVI-ICD group and 22 (47%) patients in the DDD-ICD group (P = 0.8) developed VT/VF, Overall, 73 (10%) of 725 treated episodes were inappropriate in 6 (13%) patients in the VVI group and in 10 (21%) patients in the DDD-ICD group (P = 0.2), There were 22 (31%) inappropriately treated episodes in the VVI-ICD group and 51 (69%) in the DDD-ICD group. Thirty-two of the 51 inappropriate episodes in the DDD-ICD patients resulted from intermittent atrial sensing problems that led to failure of the respective dual chamber algorithms. Nonfatal complications occurred in 6 (13%) patients in the VVI-ICD group and in 3 (6%) patients in the DDD-ICD group (P = 07). Conclusions: We conclude that the implanted DDD-ICD and conventional VVI-ICD are equally safe and effective for therapy of life-threatening ventricular tachyarrhythmias, Although DDD-ICDs allow better rhythm classification, the applied detection algorithms do not offer benefits in avoiding inappropriate therapies during supraventricular tachyarrhythmias.
引用
收藏
页码:134 / 142
页数:9
相关论文
共 27 条
  • [1] PROSPECTIVE RANDOMIZED TRIAL OF ATRIAL VERSUS VENTRICULAR PACING IN SICK-SINUS SYNDROME
    ANDERSEN, HR
    THUESEN, L
    BAGGER, JP
    VESTERLUND, T
    THOMSEN, PEB
    [J]. LANCET, 1994, 344 (8936) : 1523 - 1528
  • [2] Inappropriate shocks delivered by implantable cardiac defibrillators during oversensing of activity of diaphagmatic muscle
    Babuty, D
    Fauchier, L
    Cosnay, P
    [J]. HEART, 1999, 81 (01) : 94 - 96
  • [3] The potential usage of dual chamber pacing in patients with implantable cardioverter defibrillators
    Best, PJM
    Hayes, DL
    Stanton, MS
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1999, 22 (01): : 79 - 85
  • [4] HOLTER DOCUMENTED SUDDEN-DEATH IN A PATIENT WITH AN IMPLANTED DEFIBRILLATOR
    BIRGERSDOTTERGREEN, U
    ROSENQVIST, M
    LINDEMANS, FW
    RYDEN, L
    RADEGRAN, K
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1992, 15 (07): : 1008 - 1014
  • [5] BROUWER J, 1997, PACE, V20, P16
  • [6] Myopotential sensing by a dual chamber implantable cardioverter defibrillator: Two case reports
    Deshmukh, P
    Anderson, K
    [J]. JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 1998, 9 (07) : 767 - 772
  • [7] Variability of atrial sensing during exercise in a patient with a dual chamber ICD caused inappropriate ICD discharges
    Glotzer, TV
    Radoslovich, GA
    Neglia, J
    Zimmerman, JM
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1999, 22 (12): : 1838 - 1841
  • [8] ELECTROCARDIOGRAPHICALLY DOCUMENTED UNNECESSARY, SPONTANEOUS SHOCKS IN 241 PATIENTS WITH IMPLANTABLE CARDIOVERTER DEFIBRILLATORS
    GRIMM, W
    FLORES, BF
    MARCHLINSKI, FE
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1992, 15 (11): : 1667 - 1673
  • [9] DELETERIOUS EFFECTS OF LONG-TERM SINGLE-CHAMBER VENTRICULAR PACING IN PATIENTS WITH SICK SINUS SYNDROME - THE HIDDEN BENEFITS OF DUAL-CHAMBER PACING
    HESSELSON, AB
    PARSONNET, V
    BERNSTEIN, AD
    BONAVITA, GJ
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1992, 19 (07) : 1542 - 1549
  • [10] Discrimination of sinus rhythm, atrial flutter, and atrial fibrillation using bipolar endocardial signals
    Jung, J
    Hohenberg, G
    Heisel, A
    Strauss, D
    Schieffer, H
    Fries, R
    [J]. JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 1998, 9 (07) : 689 - 695