THREE-DIMENSIONAL MODEL-BASED SEGMENTATION IN ECHOCARDIOGRAPHY USING HIGH TEMPORAL TISSUE AND BLOOD FLOW INFORMATION

被引:0
作者
Gerrits, Inge H. [1 ]
Nillesen, Maartje M. [2 ]
Kapusta, Livia [3 ,4 ]
Thijssen, Johan M. [2 ]
de Korte, Chris L. [2 ]
机构
[1] HAN Univ Appl Sci, Acad Informat Technol & Commun, Nijmegen, Netherlands
[2] Radboud Univ Nijmegen, Dept Radiol & Nucl Med, Med Ultrasound Imaging Ctr MUSIC, Med Ctr, Nijmegen, Netherlands
[3] Childrens Heart Ctr, Dept Pediat, Nijmegen, Netherlands
[4] Tel Aviv Univ, Dana Dwek Childrens Hosp, Pediat Cardiol Unit, Sourasky Med Ctr, Tel Aviv, Israel
关键词
Three-dimensional segmentation; Model-based; decorrelation; Radiofrequency; Blood flow; Heart; LEFT-VENTRICLE; IN-VIVO; ULTRASOUND; STRAIN; QUANTIFICATION; TRACKING;
D O I
10.1016/j.ultrasmedbio.2017.04.002
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Accurate 3-D surface segmentation is a challenging task in echocardiography because of the relatively low image quality. We introduce a new method for 3-D segmentation of the endocardium involving temporal decorrelation of echo signals originating from tissue and blood using radiofrequency (RF) signals acquired in 3-D Doppler mode. Temporal features were extracted in 3-D Doppler mode, where a sequence of RF lines is recorded for each image line. Each set of RF lines is highly correlated because of the high pulse repetition frequency. However, for high blood flow, the RF signals will decorrelate over time in contrast to the endocardium, which will remain relatively highly correlated over time. These decorrelation features permit differentiation between myocardial tissue and blood flow. We describe an implementation of a 3-D segmentation model in which temporal information is used as external constraint. The model was validated in a phantom and in vivo in healthy volunteers (n = 5 5). The phantom study revealed that the model successfully segmented the artificial blood lumen even for low flow velocity and illustrated the sensitivity of the segmentations to flow rate. In healthy volunteers, high Dice similarity indices indicate that 3-D segmentation of the endocardial border in vivo is feasible. (C) 2017 World Federation for Ultrasound in Medicine & Biology.
引用
收藏
页码:2033 / 2044
页数:12
相关论文
共 39 条
  • [1] EVALUATION OF NEW ALGORITHMS FOR THE INTERACTIVE MEASUREMENT OF SURFACE-AREA AND VOLUME
    ALYASSIN, AM
    LANCASTER, JL
    DOWNS, JH
    FOX, PT
    [J]. MEDICAL PHYSICS, 1994, 21 (06) : 741 - 752
  • [2] Segmentation of real-time three-dimensional ultrasound for quantification of ventricular function: A clinical study on right and left ventricles
    Angelini, ED
    Homma, S
    Pearson, G
    Holmes, JW
    Laine, AF
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 2005, 31 (09) : 1143 - 1158
  • [3] [Anonymous], 1970, The Intelligent Eye
  • [4] FAST AND FULLY AUTOMATIC 3-D ECHOCARDIOGRAPHIC SEGMENTATION USING B-SPLINE EXPLICIT ACTIVE SURFACES: FEASIBILITY STUDY AND VALIDATION IN A CLINICAL SETTING
    Barbosa, Daniel
    Dietenbeck, Thomas
    Heyde, Brecht
    Houle, Helene
    Friboulet, Denis
    D'hooge, Jan
    Bernard, Olivier
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 2013, 39 (01) : 89 - 101
  • [5] Automatic segmentation of echocardiographic sequences by active appearance motion models
    Bosch, JG
    Mitchell, SC
    Lelieveldt, BPF
    Nijland, F
    Kamp, O
    Sonka, M
    Reiber, JHC
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 2002, 21 (11) : 1374 - 1383
  • [6] Cantinotti M, 2015, HEART FAIL REV, P1
  • [7] A level set framework with a shape and motion prior for segmentation and region tracking in echocardiography
    Dydenko, I
    Jamal, F
    Bernard, O
    D'hooge, J
    Magnin, IE
    Friboulet, D
    [J]. MEDICAL IMAGE ANALYSIS, 2006, 10 (02) : 162 - 177
  • [8] Vessel wall detection and blood noise reduction in intravascular ultrasound imaging
    Gronningsaeter, A
    Angelsen, BAJ
    Heimdal, A
    Torp, HG
    [J]. IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1996, 43 (03) : 359 - 369
  • [9] Anisotropy of the apparent frequency dependence of backscatter in formalin fixed human myocardium
    Hall, CS
    Verdonk, ED
    Wickline, SA
    Perez, JE
    Miller, JG
    [J]. JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1997, 101 (01) : 563 - 568
  • [10] Full 2D displacement vector and strain tensor estimation for superficial tissue using beam-steered ultrasound imaging
    Hansen, H. H. G.
    Lopata, R. G. P.
    Idzenga, T.
    de Korte, C. L.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2010, 55 (11) : 3201 - 3218