An approach for spasticity quantification based on the stretch reflex threshold

被引:0
|
作者
Ferreira, Joao [1 ]
Rodrigues, Paulo [1 ]
Soares, Filomena [1 ]
Machado, Jose [2 ]
机构
[1] Univ Minho, ALGORITMI, Ind Elect Dept, Campus Azurem, P-4800058 Guimaraes, Portugal
[2] Univ Minho, CT2M, Mech Engn Dept, P-4800058 Guimaraes, Portugal
关键词
spasticity qualification; stretch reflex treshold; motor disorder; ELBOW;
D O I
暂无
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
Spasticity is a common and complex motor disorder that affects more than 12 million persons in the world. There are several studies on spasticity quantification in the literature but there is still a need for measurement improvements. This paper presents the design of a mechatronic device for spasticity quantification, in joint of ankle, elbow and knees. This approach is based on the velocity dependent of the tonic stretch reflexes. The relevant variables, the measurement range and the adequate measurement systems are selected. The data acquisition system, board and software, are also defined and tested in laboratory. Next step consists of the system validation in clinical environment.
引用
收藏
页码:38 / 43
页数:6
相关论文
共 50 条
  • [1] Biomedical Device for Spasticity Quantification Based on the Velocity Dependence of the Stretch Reflex Threshold
    Ferreira, Joao
    Machado, Jose
    Moreira, Vitor
    Soares, Filomena
    2011 IEEE 16TH CONFERENCE ON EMERGING TECHNOLOGIES AND FACTORY AUTOMATION (ETFA), 2011,
  • [2] A NEW CLINICAL MEASURE OF SPASTICITY BASED ON THE TONIC STRETCH REFLEX THRESHOLD
    Levin, M. F.
    Chan-Viquez, D.
    Solomon, J. M.
    Berman, S.
    Banina, M. C.
    Frenkel-Toledo, S.
    Soroker, N.
    Liebermann, D. G.
    INTERNATIONAL JOURNAL OF STROKE, 2018, 13 : 40 - 40
  • [3] Tonic stretch reflex threshold: A new standard in spasticity measurement
    Levin, Mindy F.
    Mullick, Aditi
    Blanchette, Andreanne
    BRAIN INJURY, 2014, 28 (5-6) : 583 - 583
  • [4] Spasticity measurement based on tonic stretch reflex threshold in stroke using a portable device
    Calota, Andra
    Feldman, Anatol G.
    Levin, Mindy F.
    CLINICAL NEUROPHYSIOLOGY, 2008, 119 (10) : 2329 - 2337
  • [5] Tonic Stretch Reflex Threshold as a Measure of Spasticity: Implications for Clinical Practice
    Calota, Andra
    Levin, Mindy F.
    TOPICS IN STROKE REHABILITATION, 2009, 16 (03) : 177 - 188
  • [6] Stretch reflex spatial threshold measure discriminates between spasticity and rigidity
    Mullick, Aditi A.
    Musampa, Nadine K.
    Feldman, Anatol G.
    Levin, Mindy F.
    CLINICAL NEUROPHYSIOLOGY, 2013, 124 (04) : 740 - 751
  • [7] Change of stretch reflex threshold in spasticity: Effect of botulinum toxin injections
    Stampacchia, G
    Bradaschia, E
    Rossi, B
    ARCHIVES ITALIENNES DE BIOLOGIE, 2004, 142 (03): : 265 - 273
  • [8] Spasticity Measurement Based on Tonic Stretch Reflex Threshold in Children with Cerebral Palsy Using the PediAnklebot
    Germanotta, Marco
    Taborri, Juri
    Rossi, Stefano
    Frascarelli, Flaminia
    Palermo, Eduardo
    Cappa, Paolo
    Castelli, Enrico
    Petrarca, Maurizio
    FRONTIERS IN HUMAN NEUROSCIENCE, 2017, 11
  • [9] Upper Limb Spasticity Evaluation Based on Stretch Reflex Threshold: Method, Device, Validity and Reliability
    Hu B.-H.
    Mu J.-S.
    Zhu Z.-J.
    Zhao P.-P.
    Wang Y.
    Wang, Yong (simenkouwang@sina.com), 2018, Science Press (44): : 129 - 139
  • [10] Measurement of post-stroke spasticity based on tonic stretch reflex threshold: implications of stretch velocity for clinical practice
    Marques, Isabela Alves
    Silva, Maristella Borges
    Silva, Andrei Nakagawa
    David Luiz, Luiza Maire
    Soares, Alcimar Barbosa
    Martins Naves, Eduardo Lazaro
    DISABILITY AND REHABILITATION, 2019, 41 (02) : 219 - 225