Use of the Novel Derivatizing Agent 1,8-Diaminonapthalene With the CIP10 Sampler to Measure 4,4′-Methylene Diphenyl Diisocyanate Atmospheres

被引:4
作者
Puscasu, Silvia [1 ]
Aubin, Simon [1 ]
Sarazin, Philippe [1 ]
Richard, Lucile [1 ]
Spence, Mark [2 ]
Gagne, Sebastien [1 ]
机构
[1] Inst Rech Robert Sauve Sante & Securite Travail, Lab Div, 505 Blvd De Maisonneuve Ouest, Montreal, PQ H3A 3C2, Canada
[2] Int Isocyanate Inst, 3 Sci Off,Bridgewater House,Whitworth St, Manchester M1 6LT, Lancs, England
关键词
1,8-diaminonaphthalene; exposure assessment methodology; isocyanate; methylene diphenyl diisocyanate; perimidone; OCCUPATIONAL ASTHMA; HEXAMETHYLENE DIISOCYANATE; RESPIRATORY-DISEASE; ISOCYANATES; AEROSOLS; TDI;
D O I
10.1093/annweh/wxx023
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
DAN is a novel derivatizing agent for isocyanate sampling which targets total reactive isocyanate group (TRIG). Field evaluations have been conducted for 4,4'-Methylene diphenyl diisocyanate (MDI) sampling using DAN as the derivatizing agent in a CIP10. The perimidone formed, selective of TRIG, was analyzed in laboratory by liquid chromatography coupled to tandem mass spectrometry. Workplaces using MDI-based polyurethane spray foam and MDI wood product binder were studied. Each study compared the data obtained between the CIP10/DAN, the CIP10/MP, and a reference method. As a first evaluation, the CIP10/DAN sampled simulated MDI spray foam atmosphere in parallel with impingers (reference method) and CIP10/MP. The mean of the TRIG concentration values measured was 16% (95% confidence interval [CI], [1, 31]) higher for the CIP10/MP samples as compared to the impinger samples, while the mean TRIG concentrations found were 98% (95% CI [63, 133]) higher for the CIP10/DAN samples as compared to the impinger samples. For sampling done in a real workplace using MDI-based spray foam, the CIP10/DAN method showed lower results than the CIP10/MP method. The presence of hygroscopic DMSO used in the DAN approach is a limitation and may prevent obtaining accurate results in the spray foam atmosphere. CIP10/DAN was also studied in MDI wood product binder atmosphere. Mean TRIG concentrations found were 80% (95% CI [51, 110]) and 79% (95% CI [50, 108]) lower for the CIP10/MP and CIP10/DAN method, respectively, as compared to the reference method (a 13-mm filter coated with MP). In this case, the CIP10 may have reached its limit in this last evaluation where vapors and particles below 1 mu m were not collected as efficiently as they were with the reference method.
引用
收藏
页码:566 / 574
页数:9
相关论文
共 32 条
[31]   OCCUPATIONAL ASTHMA CAUSED BY A PREPOLYMER BUT NOT THE MONOMER OF TOLUENE DIISOCYANATE (TDI) [J].
VANDENPLAS, O ;
CARTIER, A ;
LESAGE, J ;
PERRAULT, G ;
GRAMMER, LC ;
MALO, JL .
JOURNAL OF ALLERGY AND CLINICAL IMMUNOLOGY, 1992, 89 (06) :1183-1188
[32]  
Vangronsveld E, 2015, EVALUATION MDI PARTI