Estimation of synchronous generator parameters using the standstill step-voltage test and a hybrid Genetic Algorithm

被引:24
作者
Arjona, M. A. [1 ]
Hernandez, C. [1 ]
Cisneros-Gonzalez, M. [2 ]
Escarela-Perez, R. [3 ]
机构
[1] Inst Tecnol La Laguna, Div Estudios Posgrad & Invest, Torreon 27266, Coahuila, Mexico
[2] Inst Tecnol Valle del Guadiana, Dept Ciencias Basicas, Durango 34371, Mexico
[3] Univ Autonoma Metropolitana Azcapotzalco, Dept Energia, Mexico City 02200, DF, Mexico
关键词
Synchronous generator; Parameter; Estimation; Genetic Algorithms; dc-Step voltage; MACHINE PARAMETERS; IDENTIFICATION; DESIGN;
D O I
10.1016/j.ijepes.2011.10.003
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The parameter estimation of a synchronous generator using the dc-step voltage is presented in this paper. The dc-step voltage is a standstill experiment needed to generate the required data to estimate the fundamental parameters of the d-q axis equivalent circuits. A hybrid Genetic Algorithm is used in the estimation process. A model with one damper winding along each axis is adopted. The unequal mutual effect of field and d-axis damper windings is taken into account. To check the validity of the estimated parameters, a sudden three-phase short-circuit test is applied at the generator terminals. The measured data are compared against the simulation response of the machine model using the parameters estimated from the dc-step voltage. Furthermore, the description of the developed experimental setups for both standstill and online tests is presented. A synchronous generator of 7 kVA, 220 V. 1800 rpm, 60 Hz was used in the study. (C) 2011 Elsevier Ltd. All rights reserved.
引用
收藏
页码:105 / 111
页数:7
相关论文
共 29 条
[1]  
Adkins B., 1975, GEN THEORY ALTERNATI
[2]   A two-loop excitation control system for synchronous generators [J].
Alvarez-Ramirez, J ;
Cervantes, I ;
Escarela-Perez, R ;
Espinosa-Pereza, G .
INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2005, 27 (08) :556-566
[3]  
[Anonymous], 115 IEEE
[4]  
[Anonymous], 1985, 344 IEC BRIT STAND
[5]  
[Anonymous], 2003, 1110 IEEE
[6]   TIME-DOMAIN IDENTIFICATION OF SYNCHRONOUS MACHINE PARAMETERS FROM SIMPLE STANDSTILL TESTS [J].
BOJE, ES ;
BALDA, JC ;
HARLEY, RG .
IEEE TRANSACTIONS ON ENERGY CONVERSION, 1990, 5 (01) :164-175
[7]   CAUSES OF DISCREPANCIES ON CALCULATION OF ROTOR QUANTITIES AND EXACT EQUIVALENT DIAGRAMS OF SYNCHRONOUS MACHINE [J].
CANAY, IM .
IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1969, PA88 (07) :1114-&
[8]   Population-Based Design of Surface-Mounted Permanent-Magnet Synchronous Machines [J].
Cassimere, Brandon N. ;
Sudhoff, Scott D. .
IEEE TRANSACTIONS ON ENERGY CONVERSION, 2009, 24 (02) :338-346
[9]  
Chaoxian Han, 2011, 2011 4th International Conference on Electric Utility Deregulation and Restructuring and Power Technologies (DRPT 2011), P959, DOI 10.1109/DRPT.2011.5994032
[10]   Synchronous machine model parameters estimation by a time-domain identification method [J].
Dehghani, M. ;
Karrari, M. ;
Rosehart, W. ;
Malik, O. P. .
INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2010, 32 (05) :524-529