Microbiological comparison of a silver-coated and a non-coated needleless intravascular connector in clinical use

被引:24
作者
Casey, A. L. [1 ]
Karpanen, T. J. [1 ]
Nightingale, P. [1 ]
Cook, M. [1 ]
Elliott, T. S. J. [1 ]
机构
[1] Univ Hosp Birmingham NHS Fdn Trust, Queen Elizabeth Hosp, Birmingham B15 2TH, W Midlands, England
关键词
Intravascular; Micro-organisms; Needleless; Silver;
D O I
10.1016/j.jhin.2012.01.005
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
Background: The potential for microbial contamination of needleless intravascular (IV) connectors and the risk of subsequent infection are currently a subject of debate. Aim: To compare the number of micro-organisms associated with silver-coated and non-coated connectors in a clinical setting. Methods: Twenty-five patients with haematological malignancies who required a central venous catheter (CVC) as part of their clinical management were studied. Each patient's CVC was randomly designated to have attached either silver-coated or non-coated connectors. Before and after each manipulation of the connectors, the compression seals were decontaminated with a wipe incorporating 2% (w/v) chlorhexidine gluconate in 70% (v/v) isopropyl alcohol. Following four days in situ, the number of micro-organisms recovered from 119 silver-coated and 117 non-coated connectors was determined. Findings: Thirty-six (30.3%) silver-coated connectors had micro-organisms present on the external silicone compression seal compared to 41 (35%) non-coated connectors [odds ratio (OR): 0.8; 95% confidence interval (CI): 0.47-1.39; P = 0.49]. Conversely, the internal fluid pathway of 31 (26.1%) silver-coated connectors had micro-organisms present compared to 55 (47.0%) of the non-coated connectors (OR: 0.40; 95% CI: 0.23-0.69; P = 0.001). In addition, the total number of micro-organisms present was less in the silver-coated connectors as compared to non-coated devices (P = 0.001). Conclusion: The use of a silver-coated connector with a dedicated decontamination regime may reduce the risk of catheter-related bloodstream infection acquired via the intraluminal route. (C) 2012 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:299 / 303
页数:5
相关论文
共 7 条
[1]  
[Anonymous], 2010, STAND INF THER
[2]  
Benson J, 1992, FDA ALERT NEEDLE STI
[3]  
Casey Anna L, 2007, Nurs Stand, V22, P38
[4]   Protocol for detection of biofilms on needleless connectors attached to central venous catheters [J].
Donlan, RM ;
Murga, R ;
Bell, M ;
Toscano, CM ;
Carr, JH ;
Novicki, TJ ;
Zuckerman, C ;
Corey, LC ;
Miller, JM .
JOURNAL OF CLINICAL MICROBIOLOGY, 2001, 39 (02) :750-753
[5]   Health Care-Associated Bloodstream Infections Associated with Negative- or Positive-Pressure or Displacement Mechanical Valve Needleless Connectors [J].
Jarvis, William R. ;
Murphy, Cathryn ;
Hall, Keri K. ;
Fogle, Pamela J. ;
Karchmer, Tobi B. ;
Harrington, Glenys ;
Salgado, Cassandra ;
Giannetta, Eve T. ;
Cameron, Carol ;
Sherertz, Robert J. .
CLINICAL INFECTIOUS DISEASES, 2009, 49 (12) :1821-1827
[6]   In Vitro Studies of a Novel Antimicrobial Luer-Activated Needleless Connector for Prevention of Catheter-Related Bloodstream Infection [J].
Maki, Dennis G. .
CLINICAL INFECTIOUS DISEASES, 2010, 50 (12) :1580-1587
[7]   Detecting bacterial colonization of implanted orthopaedic devices by ultrasonication [J].
Nguyen, LL ;
Nelson, CL ;
Saccente, M ;
Smeltzer, MS ;
Wassell, DL ;
McLaren, SG .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2002, (403) :29-37