Novel e-nose for the discrimination of volatile organic biomarkers with an array of carbon nanotubes (CNT) conductive polymer nanocomposites (CPC) sensors

被引:91
作者
Castro, M. [1 ]
Kumar, B. [1 ]
Feller, J. F. [1 ]
Haddi, Z. [2 ]
Amari, A. [2 ]
Bouchikhi, B. [2 ]
机构
[1] EUB, Smart Plast Grp, LIMATB UBS, Lorient, France
[2] Moulay Ismail Univ, Sensors Elect & Instrumentat Grp, Meknes, Morocco
关键词
Carbon nanotubes (CNT); Conductive polymer nanocomposites (CPC); Volatile organic compound (VOC); Discrimination; Principal component analysis (PCA); E-nose; Spray layer by layer (sLbL); Hierarchical structures; NUCLEAR-MAGNETIC-RESONANCE; SOLID-PHASE MICROEXTRACTION; COMPOSITE VAPOR DETECTORS; LAYER-BY-LAYER; ELECTRONIC NOSE; LUNG-CANCER; MASS-SPECTROMETRY; EXHALED BREATH; SOLVENT VAPORS; CHROMATOGRAPHY/MASS SPECTROMETRY;
D O I
10.1016/j.snb.2011.06.073
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
We report the original design of a new type of electronic nose (e-nose) consisting of only five sensors made of hierarchically structured conductive polymer nanocomposites (CPC). Each sensor benefits from both the exceptional electrical properties of carbon nanotubes (CNT) used to build the conductive architecture and the spray layer by layer (sLbL) assembly technique, which provides the transducers with a highly specific 3D surface structure. Excellent sensitivity and selectivity were obtained by optimizing the amount of CNT with five different polymer matrices: poly(caprolactone) (PCL), poly(lactic acid) (PLA), poly(carbonate) (PC), poly(methyl methacrylate) (PMMA) and a biobased polyester (BPR). The ability of the resulting e-nose to detect nine organic solvent vapours (isopropanol, tetrahydrofuran, dichloromethane, n-heptane, cyclohexane, methanol, ethanol, water and toluene), as well as biomarkers for lung cancer detection in breath analysis, has been demonstrated. Principal component analysis (PCA) proved to be an excellent pattern recognition tool to separate vapour clusters. (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:213 / 219
页数:7
相关论文
共 61 条
  • [51] MEASUREMENT OF VOLATILE ORGANIC-COMPOUNDS IN EXHALED BREATH AS COLLECTED IN EVACUATED ELECTROPOLISHED CANISTERS
    PLEIL, JD
    LINDSTROM, AB
    [J]. JOURNAL OF CHROMATOGRAPHY B-BIOMEDICAL APPLICATIONS, 1995, 665 (02): : 271 - 279
  • [52] Roumanet P.J., 2009, THESIS EVRY U FRANCE
  • [53] Multiple component isolation in preparative multidimensional gas chromatography with characterisation by mass spectrometry and nuclear magnetic resonance spectroscopy
    Ruehle, Christian
    Eyres, Graham T.
    Urban, Sylvia
    Dufour, Jean-Pierre
    Morrison, Paul D.
    Marriott, Philip J.
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2009, 1216 (30) : 5740 - 5747
  • [54] Conductive polymer composites based on metallic nanofiller as smart materials for current limiting devices
    Rybak, Andrzej
    Boiteux, Gisele
    Melis, Flavien
    Seytre, Gerard
    [J]. COMPOSITES SCIENCE AND TECHNOLOGY, 2010, 70 (02) : 410 - 416
  • [55] GC analysis of human breath with a series-coupled column ensemble and a multibed sorption trap
    Sanchez, JM
    Sacks, RD
    [J]. ANALYTICAL CHEMISTRY, 2003, 75 (10) : 2231 - 2236
  • [56] An investigation of the concentration dependence and response to analyte mixtures of carbon black/insulating organic polymer composite vapor detectors
    Severin, EJ
    Doleman, BJ
    Lewis, NS
    [J]. ANALYTICAL CHEMISTRY, 2000, 72 (04) : 658 - 668
  • [57] Molecular modeling of polymer composite-analyte interactions in electronic nose sensors
    Shevade, AV
    Ryan, MA
    Homer, ML
    Manfreda, AM
    Zhou, H
    Manatt, KS
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2003, 93 (1-3): : 84 - 91
  • [58] Recognition of benzene, toluene and xylene using TGS array integrated with linear and non-linear classifier
    Szczurek, A
    Maciejewska, M
    [J]. TALANTA, 2004, 64 (03) : 609 - 617
  • [59] Polymer/carbon nanotube composites for liquid sensing: Model for electrical response characteristics
    Villmow, Tobias
    Pegel, Sven
    Poetschke, Petra
    Heinrich, Gert
    [J]. POLYMER, 2011, 52 (10) : 2276 - 2285
  • [60] Application of liquid chromatography/mass spectrometry and nuclear magnetic resonance to the identification of degradates of a novel insulin sensitizer in aqueous solutions
    Wang, MH
    Wu, YH
    Hwang, TL
    Qin, XZ
    Karki, S
    Treemaneekarn, V
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2004, 810 (02): : 209 - 219