Determination of trace lead in water samples by graphite furnace atomic absorption spectrometry after preconcentration with nanometer titanium dioxide immobilized on silica gel

被引:78
作者
Liu, Rui [1 ]
Liang, Pei [1 ]
机构
[1] Cent China Normal Univ, Coll Chem, Key Lab Pesticide & Chem Biol, Minist Educ, Wuhan 430079, Peoples R China
关键词
immobilized nanometer titanium dioxide; preconcentration; lead; graphite furnace atomic absorption spectrometry;
D O I
10.1016/j.jhazmat.2007.06.081
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Nanometer titanium dioxide immobilized on silica gel (immobilized nanometer TiO2) was prepared by sol-gel method and characterized using X-ray diffraction (XRD) and scanning electron microscope (SEM). The adsorptive capability of immobilized nanometer TiO2 for lead was assessed in this work using column method. It was found that lead can be quantitatively retained by immobilized nanometer TiO2 in the pH range 4-7, then eluted completely with 1.0 mol L-1 HCl. The adsorption capacity of immobilized nanometer TiO2 for Pb was found to be 3.16 mg g(-1). A new method has been developed for the determination of trace lead based on preconcentration with a microcolumn packed with immobilized nanometer TiO2 prior to its determination by graphite furnace atomic absorption spectrometry (GFAAS). The detection limit of this method for Pb was 9.5 ng L-1 with an enrichment factor of 50, and the relative standard deviations (R.S.D.s) was 3.2% at the 10 ng mL(-1) Pb level. The method was validated using a certified reference material, and was applied for the determination of trace lead in water samples. (C) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:166 / 171
页数:6
相关论文
共 31 条
[1]  
Ajayan P. M., 2003, NANOCOMPOSITE SCI TE
[2]  
[Anonymous], 2006, GUID DRINK WAT QUAL, V1
[3]   On-line coupling of electrochemical preconcentration in tungsten coil electrothermal atomic absorption spectrometry for determination of lead in natural waters [J].
Barbosa, F ;
Krug, FJ ;
Lima, EC .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1999, 54 (08) :1155-1166
[4]   Determination of lead in water samples by graphite furnace atomic absorption spectrometry after cloud point extraction [J].
Chen, JR ;
Xiao, SM ;
Wu, XH ;
Fang, KM ;
Liu, WH .
TALANTA, 2005, 67 (05) :992-996
[5]   AN EFFICIENT FLOW-INJECTION SYSTEM WITH ONLINE ION-EXCHANGE PRECONCENTRATION FOR THE DETERMINATION OF TRACE AMOUNTS OF HEAVY-METALS BY ATOMIC-ABSORPTION SPECTROMETRY [J].
FANG, ZL ;
RUZICKA, J ;
HANSEN, EH .
ANALYTICA CHIMICA ACTA, 1984, 164 (OCT) :23-39
[6]   FLAME ATOMIC-ABSORPTION SPECTROMETRIC DETERMINATION OF LEAD IN BIOLOGICAL SAMPLES USING A FLOW-INJECTION SYSTEM WITH ONLINE PRECONCENTRATION BY COPRECIPITATION WITHOUT FILTRATION [J].
FANG, ZL ;
SPERLING, M ;
WELZ, B .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1991, 6 (04) :301-306
[7]  
FRITZ JS, 1999, ANAL SOLID PHASE EXT
[8]  
Ghaedi M, 2006, CHEM ANAL-WARSAW, V51, P593
[9]   TiO2-assisted degradation of environmentally relevant organic compounds in wastewater using a novel fluidized bed photoreactor [J].
Haarstrick, A ;
Kut, OM ;
Heinzle, E .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1996, 30 (03) :817-824
[10]   Preconcentration and determination of trace amounts of lead (III) as thenoyltrifluoroacetone complex with dibenzo-18-crown-6 by synergistic extraction and atomic absorption spectrometry [J].
Hossain, KZ ;
Honjo, T .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1998, 361 (05) :451-454