Low velocity impact performance investigation on square hollow glass columns via full-scale experiments and Finite Element analyses

被引:36
作者
Bedon, Chiara [1 ]
Kalamar, Roman [2 ]
Eliasova, Martina [2 ]
机构
[1] Univ Trieste, Dept Engn & Architecture, Piazzale Europa 1, I-34127 Trieste, Italy
[2] Czech Tech Univ, Dept Steel & Timber Struct, Thakurova 7, Prague 16629 6, Czech Republic
关键词
Structural glass columns; Adhesive joints; Experimental tests; Finite-Element numerical investigation; Low velocity impact loads; LAMINATED GLASS; NUMERICAL-ANALYSIS; BLAST; BEHAVIOR; SIMULATION; LOADS; BEAMS;
D O I
10.1016/j.compstruct.2017.09.055
中图分类号
O3 [力学];
学科分类号
08 ; 0801 ;
摘要
Taking advantage of two full-scale experimental tests carried out on square hollow glass columns under low velocity impacts, the paper aims to further assess via Finite Element models the structural performance of such structural systems. In them, the resisting cross-section consists of four adhesively bonded laminated glass panes. Adhesive joints are also used for the connection between glass columns and top/bottom restraints. As a result, careful consideration in the analysis and design of these innovative systems is required, to guarantee appropriate fail-safe design principles for a typically tensile brittle material, as well as to account for possible accidental or exceptional loading conditions. Simplified but computationally efficient FE models are validated in the paper towards the available full-scale test results. Key aspects in the observed overall performances under low velocity impact are then emphasized, with careful consideration for several loading configurations, including variations in the release distance for the impacting mass as well as in the type of impact (hard/soft body). In conclusion, a FE sensitivity analysis is also carried out, giving preliminary evidence of the effects of some main input parameters on the overall performance of the examined systems, including possible localized damage in glass, as well as geometrical and mechanical features in the column restraints.
引用
收藏
页码:311 / 325
页数:15
相关论文
共 35 条
  • [1] Compressive behaviour of laminated structural glass members
    Aiello, Salvatore
    Campione, Giuseppe
    Minafo, Giovanni
    Scibilia, Nunzio
    [J]. ENGINEERING STRUCTURES, 2011, 33 (12) : 3402 - 3408
  • [2] Buckling of Laminated Glass Elements in Compression
    Amadio, C.
    Bedon, C.
    [J]. JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 2011, 137 (08): : 803 - 810
  • [3] Elastoplastic dissipative devices for the mitigation of blast resisting cable-supported glazing facades
    Amadio, Claudio
    Bedon, Chiara
    [J]. ENGINEERING STRUCTURES, 2012, 39 : 103 - 115
  • [4] [Anonymous], 57222004 EN EUR COMM
  • [5] [Anonymous], 126002002 EN EUR COM
  • [6] Numerical analysis of glass-FRP post-tensioned beams - Review and assessment
    Bedon, Chiara
    Louter, Christian
    [J]. COMPOSITE STRUCTURES, 2017, 177 : 129 - 140
  • [7] Design buckling curves for glass columns and beams
    Bedon, Chiara
    Amadio, Claudio
    [J]. PROCEEDINGS OF THE INSTITUTION OF CIVIL ENGINEERS-STRUCTURES AND BUILDINGS, 2015, 168 (07) : 514 - 526
  • [8] Numerical and analytical investigation on the dynamic buckling behavior of glass columns under blast
    Bedon, Chiara
    Amadio, Claudio
    Sinico, Andrea
    [J]. ENGINEERING STRUCTURES, 2014, 79 : 322 - 340
  • [9] Exploratory numerical analysis of SG-laminated reinforced glass beam experiments
    Bedon, Chiara
    Louter, Christian
    [J]. ENGINEERING STRUCTURES, 2014, 75 : 457 - 468
  • [10] Flexural-torsional buckling: Experimental analysis of laminated glass elements
    Bedon, Chiara
    Amadio, Claudio
    [J]. ENGINEERING STRUCTURES, 2014, 73 : 85 - 99