Health effects associated with indoor swimming pools: A suspected toxic chloramine exposure

被引:46
作者
Kaydos-Daniels, S. Cornelia [1 ,2 ]
Beach, Michael J. [3 ]
Shwe, Thein [1 ]
Magri, Julie [4 ]
Bixler, Danae [1 ]
机构
[1] W Virginia Bureau Publ Hlth, Charleston, WV USA
[2] Ctr Dis Control & Prevent, Epidem Intelligence Serv, Atlanta, GA USA
[3] Ctr Dis Control & Prevent, Natl Ctr Zoonot, Div Parasit Dis, Atlanta, GA USA
[4] Ctr Dis Control & Prevent, Off Workforce & Career Dev, Career Dev Div, Atlanta, GA USA
关键词
D O I
10.1016/j.puhe.2007.06.011
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
Objectives: A cohort and environmental study tested the hypothesis that suspected exposure to chloramines (by-products of chlorine for disinfection and ammonia from human sources) from a hotel's indoor swimming pool was associated with an outbreak among children who had attended a party at the pool. Study design: Retrospective cohort study. Methods: A case was defined as any hotel guest/visitor on 5-6 October 2002 who experienced three or more symptoms typical of chloramine exposure on either day after visiting the hotel. A cohort study and an environmental assessment were performed to determine the association between pool exposure and illness. Results: Of 128 individuals interviewed, 32 met the case definition. Common symptoms among case patients were cough (84%), eye irritation (78%) and rash (34%). Illness was associated with entering the pool area [odds ratio (OR) 19.9; 95% confidence interval (CI) 2.3-172], but more strongly with swimming (OR 72.0; 95% CI 9.1-568). Pool chloramine levels on 6 October 2002 were >= 0.7ppm (optimal level = 0 ppm; state maximum = 0.5 ppm). The pool operator lacked format training in pool maintenance. Conclusions: High chloramine levels may have caused illness in individuals who were either in or near the pool. This outbreak underscores the need for regular pool maintenance, improved air quality, education and certification for all operators of public and semipubtic pools, and education about healthy swimming practices. Published by Elsevier Ltd. The Royal Institute of Public Health.
引用
收藏
页码:195 / 200
页数:6
相关论文
共 13 条
[1]  
[Anonymous], STAT ABSTR US 1995
[2]   Lung hyperpermeability and asthma prevalence in schoolchildren: unexpected associations with the attendance at indoor chlorinated swimming pools [J].
Bernard, A ;
Carbonnelle, S ;
Michel, O ;
Higuet, S ;
de Burbure, C ;
Buchet, JP ;
Hermans, C ;
Dumont, X ;
Doyle, I .
OCCUPATIONAL AND ENVIRONMENTAL MEDICINE, 2003, 60 (06) :385-394
[3]  
Emanuel BP, 1998, J ENVIRON HEALTH, V61, P17
[4]  
GAGINAIRE F, 1994, J APPL TOXICOL, V14, P405
[5]  
Goyder E C, 2000, Commun Dis Public Health, V3, P208
[6]   EXPOSURE TO CHLORAMINES IN THE ATMOSPHERE OF INDOOR SWIMMING POOLS [J].
HERY, M ;
HECHT, G ;
GERBER, JM ;
GENDRE, JC ;
HUBERT, G ;
REBUFFAUD, J .
ANNALS OF OCCUPATIONAL HYGIENE, 1995, 39 (04) :427-439
[7]   Respiratory symptoms and bronchial responsiveness in lifeguards exposed to nitrogen trichloride in indoor swimming pools [J].
Massin, N ;
Bohadana, AB ;
Wild, P ;
Hery, M ;
Toamain, J ;
Hubert, G .
OCCUPATIONAL AND ENVIRONMENTAL MEDICINE, 1998, 55 (04) :258-263
[8]   COUGHING WATER - BRONCHIAL HYPER-REACTIVITY INDUCED BY SWIMMING IN A CHLORINATED POOL [J].
MUSTCHIN, CP ;
PICKERING, CAC .
THORAX, 1979, 34 (05) :682-683
[9]   Mass casualties from acute inhalation of chloramine gas [J].
Pascuzzi, TA ;
Storrow, AB .
MILITARY MEDICINE, 1998, 163 (02) :102-104
[10]   SWIMMING POOL WHEEZING [J].
PENNY, PT .