On-pump beating heart versus conventional on-pump coronary artery bypass grafting on clinicaloutcomes: a meta-analysis

被引:3
|
作者
Wang, Chen [1 ]
Jiang, Yefan [1 ]
Jiang, Xionggang [1 ]
Chen, Si [1 ]
机构
[1] Huazhong Univ Sci & Technol, Union Hosp, Tongji Med Coll, Dept Cardiovasc Surg & Heart Transplantat, Wuhan 43000, Peoples R China
关键词
Coronary artery bypass graft (CABG); on-pump; beating heart; meta-analysis; LONG-TERM OUTCOMES; OFF-PUMP; CARDIOPLEGIC ARREST; EXTRACORPOREAL-CIRCULATION; CARDIOPULMONARY BYPASS; MYOCARDIAL-INFARCTION; SURGERY; REVASCULARIZATION; MORTALITY; CONVERSION;
D O I
10.21037/jtd-21-568
中图分类号
R56 [呼吸系及胸部疾病];
学科分类号
摘要
Background: A hybrid surgery method, on-pump beating heart coronary artery bypass graft (ON-BH CABG), is supposed to be a promising technology for coronary artery revascularization. Here, we conducted a comprehensive meta-analysis of the data derived from published studies on ON-BH CABG and conventional on-pump coronary artery bypass graft (C-CABG) to compare their short-term and long-term clinical outcomes. Methods: We searched major electronic databases and 24 studies incorporating 6,862 patients (1,847 ON-BH CABG and 5,015 C-CABG) were included eventually, and 9 studies of them were focusing on high-risk patients. Results: Compared with ON-BH CABG, C-CABG was associated with a higher risk in early mortality [odds ratio (OR), 1.45; 95% confidence interval (CI), 1.09 to 1.93; P=0.01], myocardial infarction (MI) (OR, 2.60; 95% CI, 1.41 to 4.78; P<0.01), low output syndrome (LOS) (OR, 2.56; 95% CI, 1.55 to 4.23; P<0.01), renal failure (OR, 1.84; 95% CI, 1.38 to 2.44; P<0.01). In contrast, there was no significant difference in long-term survival [hazard ratio (HR), 1.08; 95% CI, 0.81 to 1.43; P=0.60]. In systematic analysis of the studies in high-risk patients, ON-BEI CABG showed a lower risk in terms of early mortality, intra-aortic balloon pump (!ABP) usage, renal failure, hemodialysis, MI and pulmonary complication. No significant difference was observed in the long-term survival between ON-BH CABG and C-CABG. Conclusions: With experienced and adept surgical team and mature ON-BH technology, ON-BH CABG may reduce the risk of postoperative death and complications in some patients. It might be an attractive alternative for high-risk patient populations.
引用
收藏
页码:4169 / 4184
页数:16
相关论文
共 50 条
  • [31] On-pump beating heart coronary artery bypass grafting surgery for high risk patients
    Seguel S, Enrique
    Farias M, Juan
    Gonzalez L, Roberto
    Alarcon C, Emilio
    Stockins L, Aleck
    Cardenas M, Patricio
    REVISTA CHILENA DE CIRUGIA, 2011, 63 (01): : 15 - 20
  • [32] Comparison of renal outcomes in off-pump versus on-pump coronary artery bypass grafting: A systematic review and meta-analysis of randomized controlled trials
    Cheungpasitporn, Wisit
    Thongprayoon, Charat
    Kittanamongkolchai, Wonngarm
    Srivali, Narat
    O'Corragain, Oisin A.
    Edmonds, Peter J.
    Ratanapo, Supawat
    Spanuchart, Ittikorn
    Erickson, Stephen B.
    NEPHROLOGY, 2015, 20 (10) : 727 - 735
  • [33] Off-pump versus on-pump coronary artery bypass grafting for octogenarians: A meta-analysis involving 146 372 patients
    Sun, Lifu
    Zhou, Meijing
    Ji, Yumeng
    Wang, Xufeng
    Wang, Xiaowei
    CLINICAL CARDIOLOGY, 2022, 45 (04) : 331 - 341
  • [34] The influence of on-pump and off-pump coronary artery bypass grafting on hemorheological parameters
    Papp, J.
    Toth, A.
    Sandor, B.
    Kiss, R.
    Rabai, M.
    Kenyeres, P.
    Juricskay, I.
    Kesmarky, G.
    Szabados, S.
    Toth, K.
    CLINICAL HEMORHEOLOGY AND MICROCIRCULATION, 2011, 49 (1-4) : 331 - 346
  • [35] A meta-analysis of randomized trials for repeat revascularization following off-pump versus on-pump coronary artery bypass grafting
    Takagi, Hisato
    Mizuno, Yusuke
    Niwa, Masao
    Goto, Shin-nosuke
    Umemoto, Takuya
    INTERACTIVE CARDIOVASCULAR AND THORACIC SURGERY, 2013, 17 (05) : 878 - 880
  • [36] OFF-PUMP VERSUS ON-PUMP CORONARY ARTERY BYPASS GRAFTING: WHO BENEFITS?
    Pawliszak, Wojciech
    Kowalewski, Mariusz
    Anisimowicz, Lech
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2015, 150 (06): : 1666 - 1668
  • [37] Coronary artery bypass grafting off-pump or on-pump: another brick in the wall
    Calafiore, Antonio M.
    Prapas, Sotirios
    Osman, Ahmed
    Di Mauro, Michele
    ANNALS OF TRANSLATIONAL MEDICINE, 2017, 5 (07)
  • [38] Off-pump versus on-pump coronary artery bypass grafting for ischaemic heart disease
    Moller, Christian H.
    Penninga, Luit
    Wetterslev, Jorn
    Steinbruchel, Daniel A.
    Gluud, Christian
    COCHRANE DATABASE OF SYSTEMATIC REVIEWS, 2012, (03):
  • [39] On-pump Beating Heart Surgery
    Mo, Ansheng
    Lin, Hui
    HEART LUNG AND CIRCULATION, 2011, 20 (05): : 295 - 304
  • [40] Outcomes of off-pump versus on-pump coronary artery bypass grafting: Impact of preoperative risk
    Polomsky, Marek
    He, Xia
    O'Brien, Sean M.
    Puskas, John D.
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2013, 145 (05): : 1193 - 1198