The influence of the design methodology in the response of transmission towers to wind loading

被引:50
|
作者
Loredo-Souza, AM
Davenport, AG
机构
[1] Univ Fed Rio Grande Sul, Lab Aerodinam Construcoes, Dept Civil Engn, BR-90035190 Porto Alegre, RS, Brazil
[2] Univ Western Ontario, Boundary Layer Wind Tunnel Lab, London, ON N6A 5B9, Canada
关键词
wind; towers; transmission lines; codes; steel structures;
D O I
10.1016/S0167-6105(03)00048-5
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
From a theoretical approach, the design procedure for the establishment of wind loading on transmission towers was reviewed and current procedures, such as Davenport's gust response factor (GRF), were compared with the statistical method using influence lines (SIL), which is considered more realistic. This latter approach can account for unbalanced loading effects, shear and axial loads and the effects of higher modes of vibration in the calculation of the response factors. Several responses due to certain assumed transverse wind characteristics were calculated for some typical transmission towers. The main findings were: (a) Peak loads calculated using SIL were larger than peak loads given by the GRF. (b) The dynamic response of transmission structures is strongly dependent on the turbulence intensity level and its spectrum. (c) For members in which there is reversal in the forces on the load position, the resonant response in the second mode of vibration was bigger, even by four to five times, than the corresponding one in the first mode. Although this effect is not as severe in terms of resulting stresses when all the components are computed in the peak responses, it can lead to fatigue problems. From the current results it can be concluded that the incorporation of the dynamic properties of transmission structures in the design methodologies is needed and that the statistical method using influence lines is a more correct approach since it allows for the inclusion of a larger number of factors in the design methodology. (C) 2003 Elsevier Ltd. All rights reserved.
引用
收藏
页码:995 / 1005
页数:11
相关论文
共 50 条
  • [1] Optimum design of transmission towers subjected to wind and earthquake loading
    Galeb, A. C. (alaagaleb@yahoo.com), 1600, Jordan University of Science and Technology (07):
  • [2] Optimum Design of Transmission Towers Subjected to Wind and Earthquake Loading
    Galeb, Alaa C.
    Khayoon, Ahmed Mohammed
    JORDAN JOURNAL OF CIVIL ENGINEERING, 2013, 7 (01) : 70 - 92
  • [3] Dynamic response of transmission lines guyed towers under wind loading
    Gani, F.
    Legeron, F.
    CANADIAN JOURNAL OF CIVIL ENGINEERING, 2010, 37 (03) : 450 - 464
  • [4] Examination of Yawed Wind Loading on Transmission Towers
    Mara, T. G.
    Behncke, R. H.
    ELECTRICAL TRANSMISSION AND SUBSTATION STRUCTURES 2015: TECHNICAL CHALLENGES AND INNOVATIVE SOLUTIONS IN GRID MODERNIZATION, 2015, : 522 - 537
  • [5] WIND LOADING AND RESPONSE OF COOLING-TOWERS
    SOLLENBERGER, NJ
    SCANLAN, RH
    BILLINGTON, DP
    JOURNAL OF THE STRUCTURAL DIVISION-ASCE, 1980, 106 (03): : 601 - 621
  • [6] Assessment of capacity curves for transmission line towers under wind loading
    Banik, S. S.
    Hong, H. P.
    Kopp, Gregory A.
    WIND AND STRUCTURES, 2010, 13 (01) : 1 - 20
  • [7] WIND LOADING ON COOLING TOWERS
    Armitt, John
    1980, 106 (03): : 623 - 641
  • [8] Design wind loads for tubular-angle steel cross-arms of transmission towers under skewed wind loading
    Yang, Fengli
    Yang, Jingbo
    Niu, Huawei
    Zhang, Hongjie
    JOURNAL OF WIND ENGINEERING AND INDUSTRIAL AERODYNAMICS, 2015, 140 : 10 - 18
  • [9] Dynamic Response of Power Transmission Towers under Wind Load
    Li Pengyun
    Lin Jiedong
    Nie Ming
    Zhong Wanli
    Huang Anguo
    2012 INTERNATIONAL CONFERENCE ON FUTURE ELECTRICAL POWER AND ENERGY SYSTEM, PT B, 2012, 17 : 1124 - 1131
  • [10] Influence of Shallow Foundations on the Response of Steel Wind Towers
    Campione, Giuseppe
    INTERNATIONAL JOURNAL OF CIVIL ENGINEERING, 2024, 22 (07) : 1309 - 1319