A potential role for endobronchial valves in patients with lung transplant

被引:6
作者
Kemp, Samuel V. [1 ]
Carby, Martin [2 ]
Cetti, Edward J. [1 ]
Herth, Felix J. F. [3 ]
Shah, Pallav L. [1 ]
机构
[1] Royal Brompton Hosp, London SW3 6LY, England
[2] Harefield Hosp, Dept Transplant Med, Harefield UB9 6JH, Middx, England
[3] Univ Heidelberg, Thoraxklin, Heidelberg, Germany
关键词
VOLUME REDUCTION; DYNAMIC HYPERINFLATION; NATIVE LUNG; EMPHYSEMA;
D O I
10.1016/j.healun.2010.06.011
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
引用
收藏
页码:1310 / 1312
页数:3
相关论文
共 7 条
[1]  
Anderson MB, 1997, J HEART LUNG TRANSPL, V16, P752
[2]   Use of endobronchial valves for native lung hyperinflation respiratory failure associated with in a single-lung transplant recipient for emphysema [J].
Crespo, Maria M. ;
Johnson, Bruce A. ;
McCurry, Kenneth R. ;
Landreneau, Rodney J. ;
Sciurba, Frank C. .
CHEST, 2007, 131 (01) :214-216
[3]  
*DEP HLTH, PAYM RES ARR 2008 20
[4]   Effect of Bronchoscopic lung volume reduction on dynamic hyperinflation and exercise in emphysema [J].
Hopkinson, NS ;
Toma, TP ;
Hansell, DM ;
Goldstraw, P ;
Moxharn, J ;
Geddes, DM ;
Polkey, MI .
AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2005, 171 (05) :453-460
[5]   Bronchoscopic volume reduction with valve implants in patients with severe emphysema. [J].
Toma, TP ;
Hopkinson, NS ;
Hillier, J ;
Hansell, DM ;
Morgan, C ;
Goldstraw, PG ;
Polkey, MI ;
Geddes, DM .
LANCET, 2003, 361 (9361) :931-933
[6]   Dynamic hyperinflation: A new entity after unilateral lung transplantation for emphysema [J].
Verschuuren, E. A. M. ;
Grevink, R. G. ;
Slebos, D. -J. ;
Erasmus, M. E. ;
Klinkenberg, T. J. ;
van der Bij, W. .
JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2008, 27 (02) :S68-S68
[7]  
2007, EUR RESP SOC 17 ANN