Development of a 2D Laser Scanning System for Blood perfusion imaging through curved sections of Human Forearm

被引:0
作者
Ambika, S. [1 ]
Archana, H. [2 ]
机构
[1] Vel Tech MultTech Dr RR Dr SR Engn Coll, Dept Biomed Engn, Madras, Tamil Nadu, India
[2] Sathyabama Univ, Dept Elect & Telecommun, Madras 600119, Tamil Nadu, India
来源
2014 International Conference on Science Engineering and Management Research (ICSEMR) | 2014年
关键词
Laser Doppler Effect; Perfusion Values; Occlusion; Rubber phantom; Interpolation; DOPPLER MEASUREMENTS; TISSUE; FLOW;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Blood flow in microcirculation has found vital role in maintenance of body temperature. Its measurement is vital in the field of skin-vessel reactivity, ageing of skin, micro vascular repair of the ulnar artery and wound healing in association with total elbow replacement. The existing techniques for blood flow measurements like Electromagnetic blood flow measurement, Thermal convection method, Dual radiographic method, Ultrasonic Blood flow measurement and NMR method are not found suitable for measurement of blood flow in microcirculation due to their large size, complexity, invasive nature of measuring element and possibility of radiation exposure to the patient. Hence, a new technology is developed for micro vascular blood flow or velocity measurement using He-Ne laser of wavelength 632.8nm.
引用
收藏
页数:6
相关论文
共 15 条
[1]   HIGH-QUALITY PHOTOPLETHYSMOGRAPH SIGNALS FROM A LASER DOPPLER FLOWMETER - PRELIMINARY STUDIES OF 2 SIMULTANEOUS OUTPUTS FROM THE FINGER [J].
ALMOND, NE ;
JONES, DP ;
COOKE, ED .
JOURNAL OF BIOMEDICAL ENGINEERING, 1988, 10 (05) :458-462
[2]   LASER DOPPLER MEASUREMENTS OF BLOOD-FLOW IN SKIN TISSUE [J].
BOGGETT, D ;
BLOND, J ;
ROLFE, P .
JOURNAL OF BIOMEDICAL ENGINEERING, 1985, 7 (03) :225-232
[3]   LASER DOPPLER MEASUREMENTS OF BLOOD VELOCITY IN HUMAN RETINAL-VESSELS [J].
FEKE, GT ;
RIVA, CE .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA, 1978, 68 (04) :526-531
[4]  
GOLDMAN L, 1981, BIOMEDICAL LASER TEC
[5]  
Khandpur R. S., 1987, Handbook of Biomedical Instrumentation
[6]  
Kumaravel M., 1994, THESIS
[7]  
Nilsson G, 1996, INT CONGR SER, V1117, P35
[8]   NEW INSTRUMENT FOR CONTINUOUS MEASUREMENT OF TISSUE BLOOD-FLOW BY LIGHT BEATING SPECTROSCOPY [J].
NILSSON, GE ;
TENLAND, T ;
OBERG, PA .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1980, 27 (01) :12-19
[9]   DEPTH DISCRIMINATION IN LASER DOPPLER SKIN BLOOD-FLOW MEASUREMENT USING DIFFERENT LASERS [J].
OBEID, AN ;
BOGGETT, DM ;
BARNETT, NJ ;
DOUGHERTY, G ;
ROLFE, P .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1988, 26 (04) :415-419
[10]  
Prakash B., 1994, THESIS