A critical analysis of the degree of conversion of resin-based luting cements

被引:24
|
作者
Noronha Filho, Jaime Dutra [1 ]
Brandao, Natasha Lamego [1 ]
Poskus, Laiza Tatiana [1 ]
Antunes Guimaraes, Jose Guilherme [1 ]
da Silva, Eduardo Moreira [1 ]
机构
[1] Univ Fed Fluminense, Fac Odontol, Sch Dent, Dept Restorat Dent, BR-24020140 Niteroi, RJ, Brazil
关键词
Resin cements; Cure; ALL-CERAMIC SYSTEMS; MECHANICAL-PROPERTIES; POLYMERIZATION EFFICIENCY; RELATIVE TRANSLUCENCY; CORE; ACTIVATION; HARDNESS;
D O I
10.1590/S1678-77572010000500003
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective: This study analyzed the degree of conversion (DC%) of four resin-based cements (All Ceram, Enforce, Rely X ARC and Variolink II) activated by two modes (chemical and dual), and evaluated the decrease of DC% in the dual mode promoted by the interposition of a 2.0-mm-thick IPS Empress 2 disc. Material and Methods: In the chemical activation, the resin-based cements were prepared by mixing equal amounts of base and catalyst pastes. In the dual activation, after mixing, the cements were light-activated at 650 mW/cm(2) for 40 s. In a third group, the cements were light-activated through a 2.0-mm-thick IPS Empress 2 disc. The DC% was evaluated in a FT-IR spectrometer equipped with an attenuated total reflectance crystal (ATR). The data were analyzed by two-way ANOVA and Tukey's HSD test. Results: For all resin-based cements, the DC% was significantly higher with dual activation, followed by dual activation through IPS Empress 2, and chemical activation (p<0.05). Irrespective of the activation mode, Rely X presented the highest DC% (p<0.05). Chemically activated Variolink and All Ceram showed the worst results (p<0.05). The DC% decreased significantly when activation was performed through a 2.0-mm-thick IPS Empress 2 disc (p<0.05). Conclusions: The results of the present study suggest that resin-based cements could present low DC% when the materials are dually activated through 2.0 mm of reinforced ceramic materials with translucency equal to or less than that of IPS-Empress 2.
引用
收藏
页码:442 / 446
页数:5
相关论文
共 50 条
  • [21] Bonding of Resin-based Luting Cements to Zirconia With and Without the Use of Ceramic Priming Agents
    Koizumi, Hiroyasu
    Nakayama, Daisuke
    Komine, Futoshi
    Blatz, Markus B.
    Matsumura, Hideo
    JOURNAL OF ADHESIVE DENTISTRY, 2012, 14 (04): : 385 - 392
  • [22] The effect of curing light and chemical catalyst on the degree of conversion of two dual cured resin luting cements
    Souza-Junior, Eduardo Jose
    Prieto, Lucia Trazzi
    Soares, Giulliana Panfiglio
    dos Santos Dias, Carlos Tadeu
    Baggio Aguiar, Flavio Henrique
    Maffei Sartini Paulillo, Luis Alexandre
    LASERS IN MEDICAL SCIENCE, 2012, 27 (01) : 145 - 151
  • [23] Effect of degree of conversion on the surface properties of polymerized resin cements used for luting glass fiber posts
    Ortiz-Magdaleno, Marine
    Bogarin-Topete, Edson R.
    Cerda-Cristerna, Bernardino I.
    Gutierrez-Sanchez, Mariana
    JOURNAL OF PROSTHETIC DENTISTRY, 2023, 130 (02): : 256.e1 - 256.e12
  • [24] Film thickness of resin-based luting contents
    ElBadrawy, WA
    ElMowafy, OM
    Pereira, CA
    JOURNAL OF DENTAL RESEARCH, 1997, 76 : 455 - 455
  • [25] The effect of curing light and chemical catalyst on the degree of conversion of two dual cured resin luting cements
    Eduardo José Souza-Junior
    Lúcia Trazzi Prieto
    Giulliana Panfiglio Soares
    Carlos Tadeu dos Santos Dias
    Flávio Henrique Baggio Aguiar
    Luís Alexandre Maffei Sartini Paulillo
    Lasers in Medical Science, 2012, 27 : 145 - 151
  • [26] Effect of various polymerization protocols on the cytotoxicity of conventional and self-adhesive resin-based luting cements
    Oguz, Ece Irem
    Hasanreisoglu, Ufuk
    Uctasli, Sadullah
    Oezcan, Mutlu
    Kiyan, Mehmet
    CLINICAL ORAL INVESTIGATIONS, 2020, 24 (03) : 1161 - 1170
  • [27] Effect of various polymerization protocols on the cytotoxicity of conventional and self-adhesive resin-based luting cements
    Ece Irem Oguz
    Ufuk Hasanreisoglu
    Sadullah Uctasli
    Mutlu Özcan
    Mehmet Kiyan
    Clinical Oral Investigations, 2020, 24 : 1161 - 1170
  • [28] Push-out bond strengths of endodontic posts bonded with different resin-based luting cements
    Huber, Lionel
    Cattani-Lorente, Maria
    Shaw, Ligia
    Kreici, Ivo
    Bouillaguet, Serge
    AMERICAN JOURNAL OF DENTISTRY, 2007, 20 (03): : 167 - 172
  • [29] Cytocompatibility of HEMA-free resin-based luting cements according to application protocols on dentine surfaces
    Soares, D. G.
    Brito, C. A.
    Tavares da Silva, R. H. B.
    Ribeiro, A. P. D.
    Hebling, J.
    de Souza Costa, C. A.
    INTERNATIONAL ENDODONTIC JOURNAL, 2016, 49 (06) : 551 - 560
  • [30] Degree of conversion of two self-adhesive resin luting cements through different lengths of fiber post
    Khabeer, Abdul
    Ahmed, Syed Z.
    Zubair, Mukarram
    Faridi, Muhammad A.
    Al-Harthi, Mamdouh A.
    JOURNAL OF ORAL SCIENCE, 2021, 63 (02) : 125 - 128