Cerebral computed tomography angiography using a 70 kVp protocol: improved vascular enhancement with a reduced volume of contrast medium and radiation dose

被引:20
作者
Cho, Eun-Suk [1 ]
Chung, Tae-Sub [1 ]
Ahn, Sung Jun [2 ]
Chong, KyoungHoon [3 ]
Baek, Jang Hun [1 ]
Suh, Sang Hyun [1 ]
机构
[1] Yonsei Univ, Gangnam Severance Hosp, Dept Radiol, Coll Med, Seoul 135720, South Korea
[2] Yonsei Univ, Gangnam Severance Hosp, Dept Radiol, Coll Med, Seoul 120752, South Korea
[3] Siemens Healthcare Korea, Seoul 120837, South Korea
关键词
Computed tomography; Angiography; Brain; Contrast media; Tube voltage; PULMONARY CT ANGIOGRAPHY; IMAGE-QUALITY; INDUCED NEPHROPATHY; TUBE VOLTAGE; KILOVOLTAGE SETTINGS; BRAIN; ARTERIES; OPACIFICATION; REDUCTION; EXPOSURE;
D O I
10.1007/s00330-014-3540-z
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
To determine the feasibility of using a 70-kVp protocol compared with a 120-kVp protocol for cerebral CT angiography. An additional target was to investigate a possible reduction in the volume of contrast medium (CM) using the 70-kVp protocol. Attenuation value and CNR for iodine were determined at various tube voltage settings using a phantom. Sixty-nine volunteers were randomly assigned to one of three protocols: group A (120-kVp and CM 64 mL), group B (70-kVp and CM 64 mL), or group C (70-kVp and CM 40 mL). The attenuation value, SNR, and CNR of cerebral arteries, subjective image quality, and radiation dose were compared among the groups. The vascular attenuation, SNR, and CNR of group B were significantly higher than those of group A. Group C had a significantly higher vascular attenuation than group A. Groups B and C were significantly better than group A with respect to subjective image quality. An effective dose of 70-kVp was 10 % lower than that of 120-kVp. Using 70-kVp improved arterial enhancement, SNR, and CNR, and provided better subjective image quality, using a 10 % lower effective dose. Furthermore, the 70-kVp protocol may both reduce volume of CM by 37.5 % and improve arterial enhancement. aEuro cent Cerebral CT angiography at 70-kVp substantially improved vascular enhancement aEuro cent Subjective image quality was better at 70-kVp, with lower radiation dose aEuro cent The volume of contrast media can be substantially reduced at 70-kVp.
引用
收藏
页码:1421 / 1430
页数:10
相关论文
共 26 条
[1]  
[Anonymous], 1990, CHRISTENSENS PHYS DI
[2]   Improved vascular opacification in cerebral computed tomography angiography with 80 kVp [J].
Bahner, ML ;
Bengel, A ;
Brix, G ;
Zuna, I ;
Kauczor, HU ;
Delorme, S .
INVESTIGATIVE RADIOLOGY, 2005, 40 (04) :229-234
[3]   Preventing nephropathy induced by contrast medium [J].
Barrett, BJ ;
Parfrey, PS .
NEW ENGLAND JOURNAL OF MEDICINE, 2006, 354 (04) :379-386
[4]   Cerebral Computed Tomography Angiography Using a Low Tube Voltage (80 kVp) and a Moderate Concentration of Iodine Contrast Material A Quantitative and Qualitative Comparison With Conventional Computed Tomography Angiography [J].
Cho, Eun-Suk ;
Chung, Tae-Sub ;
Oh, Dae Kun ;
Choi, Hyun Seok ;
Suh, Sang Hyun ;
Lee, Hyeon-Kyeong ;
Lee, Kyung Hee .
INVESTIGATIVE RADIOLOGY, 2012, 47 (02) :142-147
[5]  
Commission of the European Community, 1999, 16262 EUR COMM EUR C
[6]   Multi-detector row CT angiography of the brain at various kilovoltage settings [J].
Ertl-Wagner, BB ;
Hoffmann, RT ;
Bruning, R ;
Herrmann, K ;
Snyder, B ;
Blume, JD ;
Reiser, MF .
RADIOLOGY, 2004, 231 (02) :528-535
[7]   The Triple Rule-Out for Acute Ischemic Stroke: Imaging the Brain, Carotid Arteries, Aorta, and Heart [J].
Furtado, A. D. ;
Adraktas, D. D. ;
Brasic, N. ;
Cheng, S. -C. ;
Ordovas, K. ;
Smith, W. S. ;
Lewin, M. R. ;
Chun, K. ;
Chien, J. D. ;
Schaeffer, S. ;
Wintermark, M. .
AMERICAN JOURNAL OF NEURORADIOLOGY, 2010, 31 (07) :1290-1296
[8]   Contrast-induced nephropathy [J].
Gleeson, TG ;
Bulugahapitiya, S .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2004, 183 (06) :1673-1689
[9]   Low Kilovoltage CT of the Neck with 70 kVp: Comparison with a Standard Protocol [J].
Gnannt, R. ;
Winklehner, A. ;
Goetti, R. ;
Schmidt, B. ;
Kollias, S. ;
Alkadhi, H. .
AMERICAN JOURNAL OF NEURORADIOLOGY, 2012, 33 (06) :1014-1019
[10]   Image quality and radiation exposure at pulmonary CT angiography with 100-or 120-kVp protocol: prospective randomized study [J].
Heyer, Christoph M. ;
Mohr, Patrick S. ;
Lemburg, Stefan P. ;
Peters, Soeren A. ;
Nicolas, Volkmar .
RADIOLOGY, 2007, 245 (02) :577-583