Determination of iodide in urine based on chemiluminescence system of cerium (IV)-tween 40-iodide

被引:18
作者
Li, Huai-fen [1 ]
Xie, Cheng-gen [1 ]
机构
[1] W Anhui Univ, Anhui Prov Lab Biomimet Sensor & Detecting Techno, Sch Mat & Chem Engn, Luan 237012, Anhui, Peoples R China
关键词
Chemiluminescence; Iodide; Cerium (IV); Tween; 40; Urine; FLOW-INJECTION; ION; OXIDATION; ACID;
D O I
10.1016/j.jlumin.2011.07.002
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
In acidic medium, the oxidation reaction of cerium (IV) with iodide can produce strong chemiluminescence (CL) in the presence of surfactant tween 40 as an enhancer. On this basis, a flow injection method with CL detection was established for the determination of iodide. The method is simple, rapid and effective to determine iodide in the range of 8.0 x 10(-8)-5.0 x 10(-5) mol/L with a determination limit of 5.0 x 10(-8) mol/L. The relative standard deviation is 2.7% for the determination of 5.0 x 10(-6) mol/L iodide (n=11). The method has been applied to determine the content of iodide in urine with satisfactory results. Furthermore, it is suggested that the light emission from cerium (IV)-tween 40 reaction is probably because of the formation of singlet oxygen O-1*(2) and the emitter is excited oxygen molecular pairs O-2((1)Delta(g))O-2(1 Sigma(-)(g)) (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:30 / 34
页数:5
相关论文
共 20 条
  • [11] Flow injection determination of iodide ion in a photographic developing solution using iodide ion-selective electrode detector
    Masadome, T
    Sonoda, R
    Asano, Y
    [J]. TALANTA, 2000, 52 (06) : 1123 - 1130
  • [12] DETERMINATION OF IODIDE-ION IN IMPREGNATED CHARCOALS BY FLOW-INJECTION
    MONKS, CD
    NACAPRICHA, D
    TAYLOR, CG
    [J]. ANALYST, 1993, 118 (06) : 623 - 626
  • [13] Sensitive flow-injection amperometric detection of iodide using Mn3+ and As3+
    Nikolic, SD
    Mutic, JJ
    Lolic, AD
    Manojlovic, DD
    [J]. ANALYTICAL SCIENCES, 2005, 21 (05) : 525 - 529
  • [14] Determination of iodide by detection of iodine using gas-diffusion flow injection and chemiluminescence
    Ratanawimarnwong, N
    Amomthammarong, N
    Choengchan, N
    Chaisuwan, P
    Amatatongchai, M
    Wilairat, P
    McKelvie, ID
    Nacapricha, D
    [J]. TALANTA, 2005, 65 (03) : 756 - 761
  • [15] The origin of luminescence accompanying electrochemical reduction or chemical decomposition of peroxydisulfates
    Reshetnyak, OV
    Koval'chuk, EP
    Skurski, P
    Rak, J
    Blazejowski, J
    [J]. JOURNAL OF LUMINESCENCE, 2003, 105 (01) : 27 - 34
  • [16] Wu YY, 2000, CHINESE J ANAL CHEM, V28, P318
  • [17] Determination of tannic acid in industrial wastewater based on chemiluminescence system of KIO4-H2O2-Tween40
    Xie, Cheng-gen
    Li, Huai-fen
    [J]. LUMINESCENCE, 2010, 25 (05) : 350 - 354
  • [18] Ye L, 2000, CHEM J CHINESE U, V21, P59
  • [19] Indirect automatic determination of iodide by flame atomic absorption spectrometry
    Yebra, MC
    Cespón, RM
    [J]. ANALYTICA CHIMICA ACTA, 2000, 405 (1-2) : 191 - 196
  • [20] CHEMILUMINESCENCE DETERMINATION OF CAPTOPRIL BASED ON A RHODAMINE-B SENSITIZED CERIUM(IV) METHOD
    ZHANG, XR
    BAEYENS, WRG
    VANDERWEKEN, G
    CALOKERINOS, AC
    NAKASHIMA, K
    [J]. ANALYTICA CHIMICA ACTA, 1995, 303 (01) : 121 - 125