Negative Predictive Value of Transthoracic Core-Needle Biopsy A Multicenter Study

被引:58
作者
Fontaine-Delaruelle, Clara [1 ,3 ]
Souquet, Pierre-Jean [1 ,4 ]
Gamondes, Delphine [5 ]
Pradat, Eric [6 ]
De Leusse, Aurelie [2 ]
Ferretti, Gilbert R. [7 ,8 ]
Couraud, Sebastien [1 ,4 ]
机构
[1] CH Lyon Sud, Serv Pneumol, Hosp Civils Lyon Canc Inst, Pierre Benite, France
[2] CH Lyon Sud, Serv Imagerie, Hosp Civils Lyon Canc Inst, Pierre Benite, France
[3] Univ Lyon 1, Fac Med Lyon Est, F-69003 Lyon, France
[4] Univ Lyon 1, Fac Med Lyon Sud, EMR Ciblage Therapeut Oncol 3738, F-69495 Pierre Benite, France
[5] CH Louis Pradel, Serv Imagerie, Hosp Civils Lyon, Bron, France
[6] CH Lyon Sud, Pole IMER, F-69495 Pierre Benite, France
[7] Ctr Hosp Univ Grenoble, Clin Univ Radiol & Imagerie Med, F-38043 Grenoble, France
[8] Univ Grenoble Alpes, F-38000 Grenoble, France
关键词
PULMONARY-LESIONS; LUNG-CANCER; DIAGNOSTIC-ACCURACY; CLINICAL-PRACTICE; CT; GUIDELINES; MANAGEMENT; NODULES;
D O I
10.1378/chest.14-1907
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
BACKGROUND: Specimens collected by CT scan-guided transthoracic core-needle biopsy (TTNB) are frequently used for the diagnosis of lung nodules, but the clinical value of negative results has not been sufficiently investigated. We sought to determine the negative predictive value (NPV) of TTNB specimens and investigate predictive factors of negative results. METHODS: All consecutive TTNBs performed in three centers between 2006 and 2012 were included. The medical charts of patients with nonmalignant TTNB specimens were reviewed and classified as true or false negatives. Binary logistic regression was used for multivariate analysis. RESULTS: Overall, findings from 980 TTNB specimens were included. Malignant disease was found in 79% (n = 777) of the cases, nonmalignant disease in 6% (n = 54), and "negative" results in 15% (n = 149). For the diagnosis of malignant disease, NPV was 51%. Estimated sensitivity, specificity, and accuracy were 89%, 99%, and 90%, respectively. The complication rate was 34% (life-threatening complication in 6%). In multivariate analysis, predictive factors for a false-negative result were radiologist experience (adjusted OR [AOR], 0.996; 95% CI, [0.994-0.998]), occurrence of a complication during the procedure (AOR, 1.958; 95% CI, [1.202-3.187]), and moderate to high maximum standardized uptake value on PET scan (AOR, 7.657; 95% CI, [1.737-33.763]). In 24 cases, a second TTNB was performed at the same target. The complication rate was 33%, and TTNB specimens provided diagnosis in 95% of cases with a 67% NPV. CONCLUSIONS: One-half of all "negative" TTNB specimen results were falsely negative for malignant diagnosis. Findings in tissue collected from a second TTNB at the same target provided a final diagnosis in most cases without increasing complication rates.
引用
收藏
页码:472 / 480
页数:9
相关论文
共 18 条
[1]  
Birchard Katherine R, 2011, Semin Intervent Radiol, V28, P87, DOI 10.1055/s-0031-1273943
[2]   From randomized trials to the clinic: is it time to implement individual lung-cancer screening in clinical practice? A multidisciplinary statement from French experts on behalf of the french intergroup (IFCT) and the groupe d'Oncologie de langue francaise (GOLF) [J].
Couraud, S. ;
Cortot, A. B. ;
Greillier, L. ;
Gounant, V. ;
Mennecier, B. ;
Girard, N. ;
Besse, B. ;
Brouchet, L. ;
Castelnau, O. ;
Frappe, P. ;
Ferretti, G. R. ;
Guittet, L. ;
Khalil, A. ;
Lefebure, P. ;
Laurent, F. ;
Liebart, S. ;
Molinier, O. ;
Quoix, E. ;
Revel, M. -P. ;
Stach, B. ;
Souquet, P. -J. ;
Thomas, P. ;
Tredaniel, J. ;
Lemarie, E. ;
Zalcman, G. ;
Barlesi, F. ;
Milleron, B. .
ANNALS OF ONCOLOGY, 2013, 24 (03) :586-597
[3]   Core needle biopsy in benign lung lesions: pathologic findings in 159 cases [J].
Doxtader, Erika E. ;
Mukhopadhyay, Sanjay ;
Katzenstein, Anna-Luise A. .
HUMAN PATHOLOGY, 2010, 41 (11) :1530-1535
[4]   Adequacy of CT-guided biopsies with histomolecular subtyping of pulmonary adenocarcinomas: Influence of ATS/ERS/IASLC guidelines [J].
Ferretti, Gilbert R. ;
Busser, Benoit ;
de Fraipont, Florence ;
Reymond, Emilie ;
McLeer-Florin, Anne ;
Mescam-Mancini, Lena ;
Moro-Sibilot, Denis ;
Brambilla, Elisabeth ;
Lantuejoul, Sylvie .
LUNG CANCER, 2013, 82 (01) :69-75
[5]   CT Fluoroscopy-Guided Biopsy of 1,000 Pulmonary Lesions Performed With 20-Gauge Coaxial Cutting Needles: Diagnostic Yield and Risk Factors for Diagnostic Failure [J].
Hiraki, Takao ;
Mimura, Hidefumi ;
Gobara, Hideo ;
Iguchi, Toshihiro ;
Fujiwara, Hiroyasu ;
Sakurai, Jun ;
Matsui, Yusuke ;
Inoue, Daisaku ;
Toyooka, Shinichi ;
Sano, Yoshifumi ;
Kanazawa, Susumu .
CHEST, 2009, 136 (06) :1612-1617
[6]   Percutaneous biopsy in lung cancer [J].
Laurent, F ;
Montaudon, M ;
Latrabe, V ;
Bégueret, H .
EUROPEAN JOURNAL OF RADIOLOGY, 2003, 45 (01) :60-68
[7]   Percutaneous needle aspiration biopsy (PCNAB) of lung lesions: 5 years results with focusing on repeat PCNAB [J].
Lee, In Jae ;
Bae, Young-A ;
Kim, Dong Gyu ;
Jung, Ki-Suck ;
Im, Hyoung June ;
Lee, Kwanseop ;
Lee, Yul ;
Bae, Sang Hoon .
EUROPEAN JOURNAL OF RADIOLOGY, 2010, 73 (03) :551-554
[8]   CT-guided percutaneous core needle biopsy for small (≤20 mm) pulmonary lesions [J].
Li, Y. ;
Du, Y. ;
Yang, H. F. ;
Yu, J. H. ;
Xu, X. X. .
CLINICAL RADIOLOGY, 2013, 68 (01) :E43-E48
[9]   Managing the small pulmonary nodule discovered by CT [J].
Libby, DM ;
Smith, JP ;
Altorki, NK ;
Pasmantier, MW ;
Yankelevitz, D ;
Henschke, CI .
CHEST, 2004, 125 (04) :1522-1529
[10]   Guidelines for radiologically guided lung biopsy [J].
Manhire, A ;
Charig, M ;
Clelland, C ;
Gleeson, F ;
Miller, R ;
Moss, H ;
Pointon, K ;
Richardson, C ;
Sawicka, E .
THORAX, 2003, 58 (11) :920-936