Test-retest repeatability of the pattern electroretinogram and flicker electroretinogram

被引:7
作者
Resende, Arthur F. [1 ]
Sanvicente, Carina T. [1 ]
Eshraghi, Hamoon [2 ]
Garcia, Alberto [3 ]
Pickel, Kassandra [3 ]
Zhang, Qiang [4 ]
Waisbourd, Michael [5 ]
Katz, L. Jay [1 ]
机构
[1] Wills Eye Hosp & Res Inst, Glaucoma Res Ctr, 840 Walnut St,Suite 1140, Philadelphia, PA 19107 USA
[2] St Lukes Univ Hosp, Bethlehem, PA USA
[3] Diopsys Inc, Pine Brook, NJ USA
[4] Wills Eye Hosp & Res Inst, Vickie & Jack Farber Vision Res Ctr, Philadelphia, PA USA
[5] Tel Aviv Med Ctr & Sch Med, Sackler Fac Med, Div Ophthalmol, Tel Aviv, Israel
关键词
Steady-state pattern electroretinogram; Flicker electroretinogram; Repeatability; Electrophysiology; Reference database; CLINICAL-TRIAL DESIGN; GLAUCOMA RESEARCH COMMUNITY; DIABETIC-RETINOPATHY; ELECTROPHYSIOLOGICAL ASSESSMENT; INTRAVITREAL RANIBIZUMAB; RETINAL FUNCTION; ERG; STIMULATION; POTENTIALS; PARADIGM;
D O I
10.1007/s10633-019-09707-5
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose To evaluate the repeatability of the steady-state pattern electroretinogram (PERG) and full-field flicker electroretinogram (Flicker ERG) protocols, delivered by the office-based Neuro Optic Vision Assessment (NOVA)(TM) testing platform, in healthy subjects. Methods Healthy individuals underwent PERG (16 degrees and 24 degrees) and Flicker ERG [fixed luminance (FL) and multi-luminance (ML)] testing protocols. Test-retest repeatability of protocols was calculated using intra-class correlation coefficients (ICC). Reference values of the parameters of the aforementioned tests were also calculated. Results The ICCs for the PERG parameters ranged from 0.793 to 0.911 (p < 0.001). The ICCs for the Flicker ERG parameters ranged from 0.968 to 0.994 (p < 0.001). A linear regression analysis was applied to assess the impact of age on ERG responses. Age had a significant impact on all PERG parameters (16 degrees or 24 degrees). The phase response of the FL Flicker ERG significantly decreased with age (beta = - 0.837, p <= 0.001). The FL Flicker ERG Magnitude was also impacted with a significant quadratic effect of age (Chi = - 0.0047, p = 0.0004). Similarly, the Phase Area Under the Curve (Phase AUC) of the ML Flicker ERG significantly declined with age (beta = - 0.007, p = 0.009), and the impact on the Magnitude AUC was significant as well, with a negative quadratic age effect. Conclusions The PERG and Flicker ERG protocols, delivered by an office-based testing platform, were shown to have good-to-excellent test-retest repeatability when tests were performed in the same order and in immediate succession.
引用
收藏
页码:185 / 195
页数:11
相关论文
共 50 条
[1]   Steady-state pattern electroretinogram and short-duration transient visual evoked potentials in glaucomatous and healthy eyes [J].
Amarasekera, Dilru C. ;
Resende, Arthur F. ;
Waisbourd, Michael ;
Puri, Sanjeev ;
Moster, Marlene R. ;
Hark, Lisa A. ;
Katz, L. Jay ;
Fudemberg, Scott J. ;
Mantravadi, Anand V. .
CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2018, 46 (01) :54-61
[2]   New Mydriasis-Free Electroretinogram Recorded with Skin Electrodes in Healthy Subjects [J].
Asakawa, Ken ;
Amino, Kana ;
Iwase, Machiho ;
Kusayanagi, Yuki ;
Nakamura, Akiho ;
Suzuki, Rio ;
Yuuki, Takashi ;
Ishikawa, Hitoshi .
BIOMED RESEARCH INTERNATIONAL, 2017, 2017
[3]   ISCEV standard for clinical pattern electroretinography (PERG): 2012 update [J].
Bach, Michael ;
Brigell, Mitchell G. ;
Hawlina, Marko ;
Holder, Graham E. ;
Johnson, Mary A. ;
McCulloch, Daphne L. ;
Meigen, Thomas ;
Viswanathan, Suresh .
DOCUMENTA OPHTHALMOLOGICA, 2013, 126 (01) :1-7
[4]   Progressive Loss of Retinal Ganglion Cell Function Precedes Structural Loss by Several Years in Glaucoma Suspects [J].
Banitt, Michael R. ;
Ventura, Lori M. ;
Feuer, William J. ;
Savatovsky, Eleonore ;
Luna, Gabriel ;
Shif, Olga ;
Bosse, Brandon ;
Porciatti, Vittorio .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (03) :2346-2352
[5]   STANDARDIZED FULL-FIELD ELECTRORETINOGRAPHY - NORMAL VALUES AND THEIR VARIATION WITH AGE [J].
BIRCH, DG ;
ANDERSON, JL .
ARCHIVES OF OPHTHALMOLOGY, 1992, 110 (11) :1571-1576
[6]   Repeatability of Pattern Electroretinogram Measurements Using a New Paradigm Optimized for Glaucoma Detection [J].
Bowd, Christopher ;
Tafreshi, Ali ;
Vizzeri, Gianmarco ;
Zangwill, Linda M. ;
Sample, Pamela A. ;
Weinreb, Robert N. .
JOURNAL OF GLAUCOMA, 2009, 18 (06) :437-442
[7]  
Breitburg D., 1999, Limnol. Oceanogr, V44, P1, DOI DOI 10.1002/9781118032923.CH1
[8]   ELECTRORETINOGRAPHIC OSCILLATORY POTENTIALS PREDICT PROGRESSION OF DIABETIC-RETINOPATHY - PRELIMINARY-REPORT [J].
BRESNICK, GH ;
KORTH, K ;
GROO, A ;
PALTA, M .
ARCHIVES OF OPHTHALMOLOGY, 1984, 102 (09) :1307-1311
[9]   Anxiety in visual field testing [J].
Chew, Shenton S. L. ;
Kerr, Nathan M. ;
Wong, Aaron B. C. ;
Craig, Jennifer P. ;
Chou, Chi-Ying ;
Danesh-Meyer, Helen V. .
BRITISH JOURNAL OF OPHTHALMOLOGY, 2016, 100 (08) :1128-1133
[10]  
Cicchetti D. V, 1994, GUIDELINES CRITERIA