Clinical Utility of a Hand-Held Scanner for Breast Cancer Early Detection and Patient Triage

被引:10
|
作者
Clanahan, Julie M. [1 ]
Reddy, Sanjana [2 ]
Broach, Robyn B. [2 ]
Rositch, Anne F. [3 ]
Anderson, Benjamin O. [4 ]
Wileyto, E. Paul [5 ]
Englander, Brian S. [6 ]
Brooks, Ari D. [2 ]
机构
[1] Univ Penn, Perelman Sch Med, Philadelphia, PA 19107 USA
[2] Univ Penn, Perelman Sch Med, Dept Surg, Philadelphia, PA 19107 USA
[3] Johns Hopkins Bloomberg Sch Publ Hlth, Dept Epidemiol, Baltimore, MD USA
[4] Univ Washington, Dept Surg & Global Hlth Med, Seattle, WA 98195 USA
[5] Univ Penn, Perelman Sch Med, Dept Biostat Epidemiol & Informat, Philadelphia, PA 19107 USA
[6] Penn Hosp, Dept Radiol, Philadelphia, PA 19107 USA
关键词
MIDDLE-INCOME COUNTRIES; SUB-SAHARAN AFRICA; DIAGNOSIS; WOMEN; STAGE;
D O I
10.1200/JGO.19.00205
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
PURPOSEGlobally, breast cancer represents the most common cause of cancer death among women. Early cancer diagnosis is difficult in low- and middle-income countries, most of which are unable to support population-based mammographic screening. Triage on the basis of clinical breast examination (CBE) alone can be difficult to implement. In contrast, piezo-electric palpation (intelligent Breast Exam [iBE]) may improve triage because it is portable, low cost, has a short learning curve, and provides electronic documentation for additional diagnostic workup. We compared iBE and CBE performance in a screening patient cohort from a Western mammography center.METHODSWomen presenting for screening or diagnostic workup were enrolled and underwent iBE then CBE, followed by mammography. Mammography was classified as negative (BI-RADS 1 or 2) or positive (BI-RADS 3, 4, or 5). Measures of accuracy and ? score were calculated.RESULTSBetween April 2015 and May 2017, 516 women were enrolled. Of these patients, 486 completed iBE, CBE, and mammography. There were 101 positive iBE results, 66 positive CBE results, and 35 positive mammograms. iBE and CBE demonstrated moderate agreement on categorization (? = 0.53), but minimal agreement with mammography (? = 0.08). iBE had a specificity of 80.3% and a negative predictive value of 94%. In this cohort, only five of 486 patients had a malignancy; iBE and CBE identified three of these five. The two cancers missed by both modalities were small?a 3-mm retro-areolar and a 1-cm axillary tail.CONCLUSIONiBE performs comparably to CBE as a triage tool. Only minimal cancers detected through mammographic screening were missed on iBE. Ultimately, our data suggest that iBE and CBE can synergize as triage tools to significantly reduce the numbers of patients who need additional diagnostic imaging in resource-limited areas.
引用
收藏
页码:27 / 34
页数:8
相关论文
共 50 条
  • [1] Comparison of Automated Breast Volume Scanning and Hand-Held Ultrasound in the Detection of Breast Cancer: an Analysis of 5,566 Patient Evaluations
    Choi, Woo Jung
    Cha, Joo Hee
    Kim, Hak Hee
    Shin, Hee Jung
    Kim, Hyunji
    Chae, Eun Young
    Hong, Min Ji
    ASIAN PACIFIC JOURNAL OF CANCER PREVENTION, 2014, 15 (21) : 9101 - 9105
  • [2] Automated Breast Volume Scanner Is More Valuable Than Hand-Held Ultrasound in Diagnosis of Small Breast cancer
    Yan, Lixia
    Jing, Luxia
    Lu, Qing
    Wang, Xi
    Mao, Wujian
    Wang, Peilei
    Zhan, Mengna
    Huang, Beijian
    ULTRASOUND QUARTERLY, 2024, 40 (01) : 66 - 73
  • [3] Diagnostic value of an automated breast volume scanner compared with a hand-held ultrasound: a meta-analysis
    Zhang, Xiaohui
    Chen, Juan
    Zhou, Yidong
    Mao, Feng
    Lin, Yan
    Shen, Songjie
    Sun, Qiang
    Ouyang, Zhaolian
    GLAND SURGERY, 2019, 8 (06) : 698 - +
  • [4] Utility of Hand-Held Echocardiography in Outpatient Pediatric Cardiology Management
    Riley, Alan
    Sable, Craig
    Prasad, Aparna
    Spurney, Christopher
    Harahsheh, Ashraf
    Clauss, Sarah
    Colyer, Jessica
    Gierdalski, Marcin
    Johnson, Ashley
    Pearson, Gail D.
    Rosenthal, Joanna
    PEDIATRIC CARDIOLOGY, 2014, 35 (08) : 1379 - 1386
  • [5] Breast ultrasound: automated or hand-held? Exploring patients' experience and preference
    Mussetto, Ilaria
    Gristina, Licia
    Schiaffino, Simone
    Tosto, Simona
    Raviola, Edoardo
    Calabrese, Massimo
    EUROPEAN RADIOLOGY EXPERIMENTAL, 2020, 4 (01)
  • [6] Comparison of Automated Breast Ultrasound and Hand-Held Breast Ultrasound in the Screening of Dense Breasts
    Philadelpho, Fernanda
    Gregorio Calas, Maria Julia
    Coutinho Carneiro, Gracy de Almeida
    Silveira, Isabela Cunha
    Ribeiro Vaz, Andreia Brandao
    Coelho Nogueira, Adriana Maria
    Bergmann, Anke
    Proenca Lobo Lopes, Flavia Paiva
    REVISTA BRASILEIRA DE GINECOLOGIA E OBSTETRICIA, 2021, 43 (03): : 190 - 199
  • [7] Breast-density assessment with hand-held ultrasound: A novel biomarker to assess breast cancer risk and to tailor screening?
    Sanabria, Sergio J.
    Goksel, Orcun
    Martini, Katharina
    Forte, Serafino
    Frauenfelder, Thomas
    Kubik-Huch, Rahel A.
    Rominger, Marga B.
    EUROPEAN RADIOLOGY, 2018, 28 (08) : 3165 - 3175
  • [8] Evaluation of artificial intelligent breast ultrasound on lesion detection and characterization compared with hand-held ultrasound in asymptomatic women
    Xu, Bin
    Luo, Weidong
    Chen, Xin
    Jia, Yiping
    Wang, Mengyuan
    Tian, Lulu
    Liu, Yi
    Lei, Bowen
    Li, Jiayuan
    FRONTIERS IN ONCOLOGY, 2023, 13
  • [9] A disposable microfluidic-integrated hand-held plasmonic platform for protein detection
    Inci, Fatih
    Saylan, Yeseren
    Kojouri, Amideddin Mataji
    Ogut, Mehmet Giray
    Denizli, Adil
    Demirci, Utkan
    APPLIED MATERIALS TODAY, 2020, 18
  • [10] Hand-held, clinical dual mode ultrasound - photoacoustic imaging of rat urinary bladder and its applications
    Sivasubramanian, Kathyayini
    Periyasamy, Vijitha
    Dienzo, Rhonnie Austria
    Pramanik, Manojit
    JOURNAL OF BIOPHOTONICS, 2018, 11 (05)