Luminescence-based retrospective dosimetry using Al2O3 from mobile phones: a simulation approach to determine the effects of position

被引:26
作者
Eakins, J. S. [1 ]
Kouroukla, E. [1 ,2 ]
机构
[1] Publ Hlth England CRCE, Didcot, Oxon, England
[2] Univ Durham, Dept Archaeol, Luminescence Dating & Dosimetry Lab, Durham DH1 3LE, England
关键词
retrospective / fortuitous / emergency / accident dosimetry; Monte Carlo; optically stimulated luminescence (OSL); thermoluminescence (TL); mobile phone; aluminium oxide; ELECTRONIC COMPONENTS; WASTE; OSL;
D O I
10.1088/0952-4746/35/2/343
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Monte Carlo modelling has been performed in support of efforts to establish emergency dosimetry services based on optically or thermally stimulated luminescence (OSL/TL) of the Al2O3 substrate present on the resistors found in mobile phones, which can act as fortuitous retrospective dosemeters for photon exposures. Specifically, a range of exposure conditions has been modelled to assess the dependence of the dosimetry on factors such as the position of resistors within a phone, the orientation of the phone relative to the source, and the location of the phone relative to its owner. Variations due to the resistors' positions and the phone's orientation were generally found to contribute just a few percent to the uncertainty on the dose assessments, though the electrical contacts surrounding the resistors could potentially enhance these by several 10s of percent. But, the location of the phone was found to impact dosimetry greatly. The largest discrepancies in the results were found for low-energy exposures: for Ir-192, differences of up to an order-of-magnitude were found between resistor and whole body doses. The outcome of the work was to derive correction / calibration factors that can be applied to estimate whole body doses from OSL/TL readings, the accurate application of which would depend on the knowledge of the exposure geometry and the degree of conservatism acceptable for the dose assessment.
引用
收藏
页码:343 / 381
页数:39
相关论文
共 34 条
[1]  
[Anonymous], 2010, Ann. ICRP
[2]  
B_tter-Jensen L., 2003, Optically Stimulated Luminescence Dosimetry, V1st
[3]   Retrospective radiation dosimetry using OSL of electronic components: Results of an inter-laboratory comparison [J].
Bassinet, C. ;
Woda, C. ;
Bortolin, E. ;
Della Monaca, S. ;
Fattibene, P. ;
Quattrini, M. C. ;
Bulanek, B. ;
Ekendahl, D. ;
Burbidge, C. I. ;
Cauwels, V. ;
Kouroukla, E. ;
Geber-Bergstrand, T. ;
Mrozik, A. ;
Marczewska, B. ;
Bilski, P. ;
Sholom, S. ;
McKeever, S. W. S. ;
Smith, R. W. ;
Veronese, I. ;
Galli, A. ;
Panzeri, L. ;
Martini, M. .
RADIATION MEASUREMENTS, 2014, 71 :475-479
[4]   Photon energy dependence of three fortuitous dosemeters from personal electronic devices, measured by optically stimulated luminescence [J].
Beerten, Koen ;
Vanhavere, Filip .
RADIATION PROTECTION DOSIMETRY, 2010, 140 (03) :294-299
[5]   Thermoluminescence dosimetry of electronic components from personal objects [J].
Beerten, Koen ;
Woda, Clemens ;
Vanhavere, Filip .
RADIATION MEASUREMENTS, 2009, 44 (5-6) :620-625
[6]  
Cristy M, 1987, ORNLTM8381V1
[7]   Metallurgical recovery of metals from electronic waste: A review [J].
Cui, Jirang ;
Zhang, Lifeng .
JOURNAL OF HAZARDOUS MATERIALS, 2008, 158 (2-3) :228-256
[8]   On the effect of updated MCNP photon cross section data on the simulated response of the HPA TLD [J].
Eakins, Jonathan .
RADIATION PROTECTION DOSIMETRY, 2009, 134 (01) :66-71
[9]   Retrospective dosimetry with alumina substrate from electronic components [J].
Ekendahl, Daniela ;
Judas, Libor .
RADIATION PROTECTION DOSIMETRY, 2012, 150 (02) :134-141
[10]   Relation between organ and whole body doses and local doses measured by ESR for and realistic neutron and photon external overexposures [J].
Herve, M. L. ;
Clairand, I. ;
Trompier, F. ;
Tikunov, D. ;
Bottollier-Depois, J. F. .
RADIATION PROTECTION DOSIMETRY, 2007, 125 (1-4) :355-360