Contrasting effects of convective flow on catheter ablation lesion size: Cryo versus radiofrequency energy

被引:15
作者
Pilcher, Thomas A. [1 ]
Saul, J. Philip [1 ]
Hlavacek, Anthony M. [1 ]
Haemmerich, Dieter [1 ,2 ]
机构
[1] Med Univ S Carolina, Div Pediat Cardiol, Charleston, SC 29425 USA
[2] Clemson Univ, Dept Bioengn, Clemson, SC USA
来源
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY | 2008年 / 31卷 / 03期
关键词
ablation; biomedical engineering; SVT; VT;
D O I
10.1111/j.1540-8159.2008.00989.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Cryoablation has now become an alternative to treat many cardiac arrhythmias, and may be the treatment of choice in some patient populations. We compared the effects of convective flow on large-tip cryo and radiofrequency (RF) lesions dimensions. Methods: Cryoablation and RF ablation were performed on porcine heart sections in a saline bath with varying directed flow rates. Cryoablation was performed for 4 minutes on 50 tissue pieces with tip temperature controlled at -80 degrees C. RF ablation was performed on 50 tissue pieces for 60 seconds at 60 degrees C tip temperature. The pieces were placed in culture media for 24 hours, and then sectioned, stained, and measured. Results: Cryoablation and RF lesion sizes varied significantly with flow such that higher flow rates produced smaller cryoablation lesions and larger RF lesions (mean cryoablation volumes: 854 +/- 402, 808 +/- 217, 781 +/- 217, 359 +/- 114, and 292 +/- 117 mm(3), and mean RF volumes: 211 +/- 35, 304 +/- 79, 439 +/- 125, 525 +/- 187, and 597 +/- 126 mm(3) for 0, 1, 2, 3, and 5L/min flow rates, respectively, P < 0.0005). Trabeculated pieces had larger cryoablation lesions and smaller RF lesions than nontrabeculated ones at higher flow rate (P < 0.005). Cryoablation lesion volume increased as the time to reach -80 degrees C decreased (r(2) = 0.72). Conclusion: In contrast to RF ablation, cryoablation lesion size is smaller at high flow rates, and larger at low flow rates due to the warming effects of local convective flow. The effects of high flow are reduced in areas of trabeculation, and the time to reach -80 degrees C predicts cryoablation lesion size.
引用
收藏
页码:300 / 307
页数:8
相关论文
共 23 条
  • [1] Cryoablation for accessory pathways located near normal conduction tissues or within the coronary venous system in children and young adults
    Bar-Cohen, Y
    Cecchin, F
    Alexander, ME
    Berut, CI
    Triedman, JK
    Walsh, EP
    [J]. HEART RHYTHM, 2006, 3 (03) : 253 - 258
  • [2] Radiofrequency catheter ablation in small children: Relationship of complications to application dose
    Blaufox, AD
    Paul, T
    Saul, JP
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2004, 27 (02): : 224 - 229
  • [3] Flow effect on lesion formation in RF cardiac catheter ablation
    Cao, H
    Vorperian, VR
    Tungjitkusolmun, S
    Tsai, JZ
    Haemmerich, D
    Bin Choy, Y
    Webster, JG
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2001, 48 (04) : 425 - 433
  • [4] Cryoablation versus radiofrequency ablation for treatment of pediatric atrioventricular nodal reentrant tachycardia: Initial experience with 4-mm cryocatheter
    Collins, Kathryn K.
    Dubin, Anne M.
    Chiesa, Nancy A.
    Avasarala, Kishor
    Van Hare, George F.
    [J]. HEART RHYTHM, 2006, 3 (05) : 564 - 570
  • [5] Biophysics of radiofrequency ablation using an irrigated electrode
    Demazumder, D
    Mirotznik, MS
    Schwartzman, D
    [J]. JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2001, 5 (04) : 377 - 389
  • [6] Lengthier cryoablation and a bonus cryoapplication is associated with improved efficacy for cryothermal catheter ablation of supraventricular tachycardias in children
    Drago, Fabrizio
    Silvetti, Massimo Stefano
    De Santis, Antonella
    Grutter, Giorgia
    Andrew, Peter
    [J]. JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2006, 16 (03) : 191 - 198
  • [7] FOSTER KR, 1989, CRIT REV BIOMED ENG, V17, P25
  • [8] Interrelation of tissue temperature versus flow velocity in two different kinds of temperature-controlled catheter radiofrequency energy applications
    Gumbrecht, S
    Neuzner, J
    Pitschner, HF
    [J]. JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 1998, 2 (02) : 211 - 219
  • [9] Hepatic radiofrequency ablation with internally cooled probes: Effect of coolant temperature on lesion size
    Haemmerich, D
    Chachati, L
    Wright, AS
    Mahvi, DM
    Lee, FT
    Webster, JG
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2003, 50 (04) : 493 - 500
  • [10] Catheter ablation for atrioventricular nodal reentry tachycardia in children: A time to freeze, and a time to burn
    Kannankeril, PJ