Development of a Compact Ion Source with a Hot Hollow Cathode

被引:0
|
作者
Miyamoto, N. [1 ]
Demura, Y. [2 ]
Imakita, S. [2 ]
Kasuya, T. [2 ]
Vasquez, M. R., Jr. [2 ]
Wada, M. [2 ]
机构
[1] Nissin Ion Equipment Co LTD, Minami Ku, 575 Kuzetonoshiro Cho, Kyoto 6018205, Japan
[2] Doshisha Univ, Grad Sch Engn, Kyoto 6100394, Japan
来源
关键词
ion source; hot cathode; hollow cathode; arc discharge; hydrogen beam; argon beam; MAGNETIC-FIELD;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A compact ion source with 14 mm diameter, 30 mm long discharge region was developed. A total size of the ion source including the beam extraction system was 60 mm in diameter and 160 mm in length. A high temperature coaxial cathode consisting of thin-wall tantalum and tungsten tubes produced a discharge plasma. A source gas was supplied through the inner W tube of the coaxial cathode. A stable plasma of H-2 was maintained with the discharge current of 2.0 A at 68 A cathode heating current. The optimum H-2 gas pressure for ion beam extraction was 2x10(-2) Pa. Hydrogen ion beam current was 120 mu A (1 mA/cm(2)) at 2.0 A discharge current and 3.0 kV extraction voltage.
引用
收藏
页码:448 / +
页数:2
相关论文
共 50 条
  • [41] A Hollow-Cathode Ion Source in Glow Discharge Mass Spectrometry
    Froehlich , G.
    JOURNAL OF ANALYTICAL CHEMISTRY, 2021, 76 (01) : 112 - 128
  • [42] INVESTIGATIONS OF BEAM EMITTANCE OF A HOLLOW-CATHODE ION-SOURCE
    SAAD, HM
    HOLK, O
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS SHORT NOTES & REVIEW PAPERS, 1984, 23 (03): : 373 - 375
  • [43] CRITICAL PARAMETERS AFFECTING HOLLOW-CATHODE ION-SOURCE
    DAUGHTREY, EH
    HARRISON, WW
    ANALYTICAL CHEMISTRY, 1975, 47 (07) : 1024 - 1028
  • [44] USE OF A HOLLOW-CATHODE IN A DUOPIGATRON HYDROGEN-ION SOURCE
    TANAKA, S
    MORITA, H
    SAKURABA, J
    JAPANESE JOURNAL OF APPLIED PHYSICS, 1980, 19 (09) : 1703 - 1710
  • [45] Characteristics of end Hall ion source with magnetron hollow cathode discharge
    Tang, Deli
    Wang, Lisheng
    Pu, Shihao
    Cheng, Changming
    Chu, Paul K.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2007, 257 (796-800): : 796 - 800
  • [46] Design of triode extraction system for a dual hollow cathode ion source
    Wang Jing-Hui
    Zhu Kun
    Zhao Wei-Jiang
    Liu Ke-Xin
    CHINESE PHYSICS C, 2011, 35 (02) : 193 - 198
  • [47] DISCHARGE-BASED ION-SOURCE (WITH HOLLOW-CATHODE)
    SEMENOV, AP
    BATUEV, BSC
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 1991, 34 (01) : 180 - 182
  • [48] PLASMA COMPRESSION TYPE HOLLOW-CATHODE ION-SOURCE
    TONEGAWA, A
    SHIMOYAMA, T
    YABE, E
    TAKAYAMA, K
    TAKAGI, K
    FUKUI, R
    KIKUCHI, R
    OKAMOTO, K
    KOMIYA, S
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1987, 21 (2-4): : 212 - 214
  • [49] INFLUENCE OF METAL HYDRIDE HOLLOW CATHODE ON PENNING ION SOURCE OPERATION
    Sereda, I
    Ryabchikov, D.
    Hrechko, Ya
    Babenko, Ie
    PROBLEMS OF ATOMIC SCIENCE AND TECHNOLOGY, 2021, (01): : 65 - 68
  • [50] Hollow cathode magnetron ion source with axial extraction. II