Development of a Compact Ion Source with a Hot Hollow Cathode

被引:0
|
作者
Miyamoto, N. [1 ]
Demura, Y. [2 ]
Imakita, S. [2 ]
Kasuya, T. [2 ]
Vasquez, M. R., Jr. [2 ]
Wada, M. [2 ]
机构
[1] Nissin Ion Equipment Co LTD, Minami Ku, 575 Kuzetonoshiro Cho, Kyoto 6018205, Japan
[2] Doshisha Univ, Grad Sch Engn, Kyoto 6100394, Japan
来源
关键词
ion source; hot cathode; hollow cathode; arc discharge; hydrogen beam; argon beam; MAGNETIC-FIELD;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A compact ion source with 14 mm diameter, 30 mm long discharge region was developed. A total size of the ion source including the beam extraction system was 60 mm in diameter and 160 mm in length. A high temperature coaxial cathode consisting of thin-wall tantalum and tungsten tubes produced a discharge plasma. A source gas was supplied through the inner W tube of the coaxial cathode. A stable plasma of H-2 was maintained with the discharge current of 2.0 A at 68 A cathode heating current. The optimum H-2 gas pressure for ion beam extraction was 2x10(-2) Pa. Hydrogen ion beam current was 120 mu A (1 mA/cm(2)) at 2.0 A discharge current and 3.0 kV extraction voltage.
引用
收藏
页码:448 / +
页数:2
相关论文
共 50 条
  • [31] PRIMARY EXPERIMENT ON HIGH CURRENT HOLLOW CATHODE ION SOURCE
    Dong, Pan
    Long, Jidong
    Li, Jie
    Lan, Chaohui
    Zheng, Le
    Peng, Yufei
    Shi, Jinshui
    2015 42ND IEEE INTERNATIONAL CONFERENCE ON PLASMA SCIENCES (ICOPS), 2015,
  • [32] Further development of a gaseous ion source based on low-pressure hollow cathode glow
    Vizir, AV
    Yushkov, GY
    Oks, EM
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2000, 71 (02): : 728 - 730
  • [33] Some effects of magnetic field on a hollow cathode ion source
    Oks, EM
    Anders, A
    Brown, IG
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2004, 75 (04): : 1030 - 1033
  • [34] A COMPACT ION-SOURCE USING A HOLLOW-CATHODE DISCHARGE AND ITS APPLICATION TO THIN-FILM FORMATION
    TAKEUCHI, M
    YANAGIDA, K
    NAGASAKA, H
    TANABE, T
    MASE, H
    THIN SOLID FILMS, 1986, 144 (02) : 281 - 288
  • [35] Study the Characteristic of the Hot Cathode of High Current Ion Source
    Yuqian Chen
    Chundong Hu
    Zhimin Liu
    Yahong Xie
    Sheng Liu
    Caichao Jiang
    Journal of Fusion Energy, 2013, 32 : 536 - 539
  • [36] Study the Characteristic of the Hot Cathode of High Current Ion Source
    Chen, Yuqian
    Hu, Chundong
    Liu, Zhimin
    Xie, Yahong
    Liu, Sheng
    Jiang, Caichao
    JOURNAL OF FUSION ENERGY, 2013, 32 (05) : 536 - 539
  • [37] FEATURES OF A PLASMA ION SOURCE WITH A HOT CATHODE GAS DISCHARGE
    CIAMPI, M
    TALINI, N
    NUCLEAR INSTRUMENTS & METHODS, 1966, 43 (02): : 325 - &
  • [38] Design of triode extraction system for a dual hollow cathode ion source
    王景辉
    朱昆
    赵渭江
    刘克新
    中国物理C, 2011, (02) : 193 - 198
  • [39] A Hollow-Cathode Ion Source in Glow Discharge Mass Spectrometry
    G. Fröhlich
    Journal of Analytical Chemistry, 2021, 76 : 112 - 128
  • [40] IBIS - HOLLOW-CATHODE MULTIPOLE BOUNDARY ION-SOURCE
    FORRESTER, AT
    GOEBEL, DM
    CROW, JT
    APPLIED PHYSICS LETTERS, 1978, 33 (01) : 11 - 13