Reagentless Redox Capacitive Assaying of C-Reactive Protein at a Polyaniline Interface

被引:47
作者
Baradoke, Ausra [1 ]
Hein, Robert [1 ]
Li, Xiaoxiong [1 ]
Davis, Jason J. [1 ]
机构
[1] Univ Oxford, Dept Chem, Oxford OX1 3QZ, England
基金
“创新英国”项目;
关键词
ELECTROCHEMICAL IMPEDANCE SPECTROSCOPY; ELECTRODES; BIOSENSOR; FILMS; GOLD;
D O I
10.1021/acs.analchem.9b05633
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Methods that enable the sensitive and label-free detection of protein biomarkers are well-positioned to make potentially significant contributions to diagnostics and derived personalized healthcare. In support of this goal, a myriad of (electrochemical) methodologies have been developed; recently, electrochemical capacitance spectroscopy emerged as an impedance-derived approach which, in employing surface-confined redox-transducers, circumvents problems associated with the use of solution-phase redox-probes. Herein, we expand this scope by utilizing phytic acid-doped polyaniline as a novel redox-charging polymer support enabling the reagentless assaying of C-reactive protein in serum with good sensitivity. The construction of the sensory interface via electropolymerization allows facile tuning of the surface coverage and redox (capacitive) properties of the polymers, which, in turn, modulate both assay selectivity, fouling, and sensitivity. Significantly, this methodology is readily extendable to a wide range of electrode materials and analytes.
引用
收藏
页码:3508 / 3511
页数:4
相关论文
共 35 条
[1]   Electrochemical Immunosensor Based on Fe3O4/PANI/AuNP Detecting Interface for Carcinoembryonic Antigen Biomarker [J].
Amarasiri, Chamali ;
Thanh Binh Nguyen ;
Loc Thai Nguyen ;
Vu Thi Thu ;
Nguyen Thi My Thuy ;
Tran Dai Lam .
JOURNAL OF ELECTRONIC MATERIALS, 2017, 46 (10) :5755-5763
[2]   Combined soft lithographic and electrochemical fabrication of nanostructured platinum microelectrode arrays for miniaturized sensor applications [J].
Baradoke, Ausra ;
Juodkazyte, Jurga ;
Masilionis, Ignas ;
Selskis, Algirdas ;
Pauliukaite, Rasa ;
Valiokas, Ramunas .
MICROELECTRONIC ENGINEERING, 2019, 208 :39-46
[3]   Properties of Anti-CA125 antibody layers on screen-printed carbon electrodes modified by gold and platinum nanostructures [J].
Baradoke, Ausra ;
Jose, Bincy ;
Pauliukaite, Rasa ;
Forster, Robert J. .
ELECTROCHIMICA ACTA, 2019, 306 :299-306
[4]   Screen-printed GPH electrode modified with Ru nanoplates and PoPD polymer film for NADH sensing: Design and characterization [J].
Baradoke, Ausra ;
Pastoriza-Santos, Isabel ;
Gonzalez-Romero, Elisa .
ELECTROCHIMICA ACTA, 2019, 300 :316-323
[5]   A nanoscale redox-active composite as a low-fouling interface for capacitive assaying [J].
Bedatty Fernandes, Flavio C. ;
Andrade, Juliana R. ;
Bueno, Paulo R. .
SENSORS AND ACTUATORS B-CHEMICAL, 2019, 291 :493-501
[6]   Challenges of Electrochemical Impedance Spectroscopy in Protein Biosensing [J].
Bogomolova, A. ;
Komarova, E. ;
Reber, K. ;
Gerasimov, T. ;
Yavuz, O. ;
Bhatt, S. ;
Aldissi, M. .
ANALYTICAL CHEMISTRY, 2009, 81 (10) :3944-3949
[7]   Common Principles of Molecular Electronics and Nanoscale Electrochemistry [J].
Bueno, Paulo R. .
ANALYTICAL CHEMISTRY, 2018, 90 (12) :7095-7106
[8]   Measuring Quantum Capacitance in Energetically Addressable Molecular Layers [J].
Bueno, Paulo R. ;
Davis, Jason J. .
ANALYTICAL CHEMISTRY, 2014, 86 (03) :1337-1341
[9]   Elucidating Redox-Level Dispersion and Local Dielectric Effects within Electroactive Molecular Films [J].
Buono, Paulo R. ;
Davis, Jason J. .
ANALYTICAL CHEMISTRY, 2014, 86 (04) :1997-2004
[10]   The capacitive sensing of NS1 Flavivirus biomarker [J].
Cecchetto, Juliana ;
Fernandes, Flavio C. B. ;
Lopes, Rute ;
Bueno, Paulo R. .
BIOSENSORS & BIOELECTRONICS, 2017, 87 :949-956