An innovative hybridization of electrodialysis with reverse osmosis for brackish water desalination

被引:15
作者
Generous, Muhammad M. [1 ]
Qasem, Naef A. A. [2 ,3 ]
Zubair, Syed M. [1 ,4 ]
机构
[1] King Fahd Univ Petr & Minerals, Dept Mech Engn, Dhahran 31261, Saudi Arabia
[2] King Fahd Univ Petr & Minerals, Dept Aerosp Engn, Dhahran 31261, Saudi Arabia
[3] King Fahd Univ Petr & Minerals KFUPM, Interdisciplinary Res Ctr Membranes & Water Secur, Dhahran 31261, Saudi Arabia
[4] KA CARE Energy Res & Innovat Ctr, Dhahran, Saudi Arabia
关键词
Electrodialysis; Reverse osmosis; Coupling; Cost; Recovery; Water production; ENERGY-CONSUMPTION; RO; RECOVERY; DESIGN; PLANTS; COST; UNIT; OPTIMIZATION; PERFORMANCE; ECONOMICS;
D O I
10.1016/j.enconman.2021.114589
中图分类号
O414.1 [热力学];
学科分类号
摘要
It is reported in the literature that Electrodialysis Desalination (ED) is the most efficient for groundwater (<7 ppt), while Reverse Osmosis (RO) is for higher salinity (8-50 ppt). Thus, the present paper proposes a novel arrangement of ED-RO for brackish water desalination. ED is used first for brackish water desalination, while RO treats the highly concentrated outlet of the ED part. Energy consumption, water production, recovery ratio, and water cost are the performance indices discussed in this paper. These are presented against the influential input parameters, which are selected based on a sensitivity analysis. The results show that the new system is economically feasible for inlet salinity of 2.5-7.8 ppt. Standalone RO could be better for salinity more than eight (8) ppt, and standalone ED is better for a source salinity of less than two (2) ppt. Energy consumption results emphasize that the ED-RO integration is the most energy-effective for the feed salinity of < 9.5 ppt. The net recovery ratio for the hybrid ED-RO plant is 87.5% when ED and RO plants operate at a recovery ratio of 75% and 50%, respectively. For typical conditions and brackish water salinity of 5 ppt, ED-RO shows an outstanding performance of 0.731 kWh/m3 for energy consumption and 0.370 $/m3 for water cost. These values are better than those of standalone RO and ED plants.
引用
收藏
页数:12
相关论文
共 38 条
[1]  
[Anonymous], 2021, DUPONT SPECIALTY MEM
[2]   An operational and economic study of a reverse osmosis desalination system for potable water and land irrigation [J].
Atab, M. Sarai ;
Smallbone, A. J. ;
Roskilly, A. P. .
DESALINATION, 2016, 397 :174-184
[3]   A unified model for the detailed investigation of membrane modules and RO plants performance [J].
Avlonitis, S. A. ;
Pappas, M. ;
Moutesidis, K. .
DESALINATION, 2007, 203 (1-3) :218-228
[4]   Osmotically assisted reverse osmosis for high salinity brine treatment [J].
Bartholomew, Timothy V. ;
Mey, Laura ;
Arena, Jason T. ;
Siefert, Nicholas S. ;
Mauter, Meagan S. .
DESALINATION, 2017, 421 :3-11
[5]   Comparison of performance and economics of reverse osmosis, membrane distillation, and pressure retarded osmosis hybrid systems [J].
Choi, Yongjun ;
Kim, Seung-Hyun ;
Lee, Sangho .
DESALINATION AND WATER TREATMENT, 2017, 77 :19-29
[6]   Optimization of reverse osmosis networks with split partial second pass design [J].
Du, Yawei ;
Xie, Lixin ;
Liu, Yan ;
Zhang, Shaofeng ;
Xu, Yingjun .
DESALINATION, 2015, 365 :365-380
[7]  
El-Dessouky H.T., 2002, Fundamentals of salt water desalination, DOI DOI 10.1016/B978-0-444-50810-2.X5000-3
[8]   Economic analysis for process optimization of Chabahar Maritime University reverse osmosis desalination plant: a case study [J].
Emamjome, Atefe ;
Zahedi, Mir Mahdi ;
Ziyaadini, Morteza .
APPLIED WATER SCIENCE, 2019, 9 (04)
[9]  
Engineering Equation Solver, 2020, Engineering Equation Solver, V10.836-3D
[10]   Exergy Analysis of a Two-Pass Reverse Osmosis (RO) Desalination Unit with and without an Energy Recovery Turbine (ERT) and Pressure Exchanger (PX) [J].
Eshoul, Nuri M. ;
Agnew, Brian ;
Al-Weshahi, Mohammed A. ;
Atab, Mohanad S. .
ENERGIES, 2015, 8 (07) :6910-6925