Measurements of electrode position inside the cochlea for different cochlear implant systems

被引:35
作者
Kós, MI [1 ]
Boëx, C [1 ]
Sigrist, A [1 ]
Guyot, JP [1 ]
Pelizzone, M [1 ]
机构
[1] Univ Hosp, Dept Otolaryngol Head & Neck Surg, Cochlear Implants Ctr, Geneva, Switzerland
关键词
D O I
10.1080/00016480510039995
中图分类号
R76 [耳鼻咽喉科学];
学科分类号
100213 ;
摘要
Conclusions. This study demonstrates that the exact location of an electrode inside the cochlea needs to be assessed using two complementary measures, namely the length and angle of insertion, both of which are mandatory if one wants to prevent erroneous outcomes. Knowledge of the contact position may become very useful when tuning a cochlear implant processor in a patient with contralateral residual hearing, or in cases of binaural implants. Objective. Multichannel cochlear implants restore useful hearing to deaf patients. However, several types of intracochlear electrodes are presently available, each featuring a specific technology or design. The aim of this study was to determine precisely the intracochlear position of the contacts for different electrode arrays. Material and methods. Electrode array insertions were estimated using special radiographs. A total of 26 cochlear implantations were included in the study: 6 Ineraid(TM); 5 Clarion(TM) HiFocus I; 11 Clarion HiFocus II; and 4 Med- El(TM) Combi40 +. In each case, a measurable reference or marker ring placed close to the round window ( within 2 mm) could be identified. Insertion lengths and angles were measured and then plotted on a graph based on 3D reconstructions. Results. Both Clarion HiFocus I and II electrode arrays were found to be placed close to the inner wall of the cochlea. Ineraid and Med- El Combi40 + electrode arrays were both placed close to the organ of Corti, the Med-El Combi40 + arrays demonstrating the deepest insertions overall. In spite of marked differences in the positions of the contacts, we did not find any correlation with speech perception performance for the different types of implants studied.
引用
收藏
页码:474 / 480
页数:7
相关论文
共 35 条
[1]   Surgical technique for the CLARION® Cochlear Implant [J].
Balkany, TJ ;
Cohen, NL ;
Gantz, BJ .
ANNALS OF OTOLOGY RHINOLOGY AND LARYNGOLOGY, 1999, 108 (04) :27-30
[2]   Simultaneous Analog Stimulation (SAS) Continuous Interleaved Sampler (CIS) pilot comparison study in Europe [J].
Battmer, RD ;
Zilberman, Y ;
Haake, P ;
Lenarz, T .
ANNALS OF OTOLOGY RHINOLOGY AND LARYNGOLOGY, 1999, 108 (04) :69-73
[3]   FACTORS PREDICTING POSTOPERATIVE SENTENCE SCORES IN POSTLINGUISTICALLY DEAF ADULT COCHLEAR IMPLANT PATIENTS [J].
BLAMEY, PJ ;
PYMAN, BC ;
CLARK, GM ;
DOWELL, RC ;
GORDON, M ;
BROWN, AM ;
HOLLOW, RD .
ANNALS OF OTOLOGY RHINOLOGY AND LARYNGOLOGY, 1992, 101 (04) :342-348
[4]  
Boex C, 1996, AM J OTOL, V17, P61
[5]   Forward masked excitation patterns in multielectrode electrical stimulation [J].
Chatterjee, M ;
Shannon, RV .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1998, 103 (05) :2565-2572
[6]  
Cohen L T, 1996, Audiol Neurootol, V1, P265
[7]   Effects of the Clarion Electrode Positioning System on auditory thresholds and comfortable loudness levels in pediatric patients with cochlear implants [J].
Donaldson, GS ;
Peters, MD ;
Ellis, MR ;
Friedman, BJ ;
Levine, SC ;
Rimell, FL .
ARCHIVES OF OTOLARYNGOLOGY-HEAD & NECK SURGERY, 2001, 127 (08) :956-960
[8]   The Clarion electrode positioner: Temporal bone studies [J].
Fayad, JN ;
Luxford, W ;
Linthicum, FH .
AMERICAN JOURNAL OF OTOLOGY, 2000, 21 (02) :226-229
[9]   Speech recognition in noise as a function of the number of spectral channels: Comparison of acoustic hearing and cochlear implants [J].
Friesen, LM ;
Shannon, RV ;
Baskent, D ;
Wang, X .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2001, 110 (02) :1150-1163
[10]  
FRINJS JHM, 2001, OTOL HEAR, V22, P340