Fire behaviour and design of hybrid fibre reinforced high-performance concrete columns subjected to uniaxial bending

被引:18
作者
Du, Panwei [1 ]
Yang, Yaowen [1 ]
Tan, Kang Hai [1 ]
机构
[1] Nanyang Technol Univ, Sch Civil & Environm Engn, Singapore 639798, Singapore
基金
新加坡国家研究基金会;
关键词
High-performance concrete; Fibre reinforced concrete; Fire; Explosive spalling; Column; Eccentric loading; Slender column; STRENGTH;
D O I
10.1016/j.engstruct.2021.113425
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper presents an experimental programme and a fire design model on hybrid fibre reinforced high-performance concrete (HPC) columns under ISO 834 heating curve. To date, there are very few experimental works on HPC columns subjected to eccentric loading under fire conditions. Therefore, a total of six specimens are tested to investigate the effects of load eccentricity and slenderness ratio on spalling and structural behaviour of HPC columns. Material properties including compressive strength, residual flexural strength and spalling behaviour under unstressed state but subject to transient heating are presented to get an overview of the performance of HPC. Following that, the test results of column specimens are discussed in terms of temperature distribution, mid-height deflection, axial deformation, failure mode and fire endurance. No spalling is observed in all the specimens owing to the synergistic effect of hybrid polypropylene and steel fibres. Test results show that mid-height deflection and axial contraction increase with an increase of load eccentricity. A simplified fire design model incorporating fibre reinforced concrete design is adopted based on 500 degrees C isotherm method. The model is verified with test data and it shows that 400 degrees C isotherm depth could provide safe and accurate predictions for HPC columns.
引用
收藏
页数:17
相关论文
共 27 条
[1]  
Aldea CM, 1997, FIRE TEST NORMAL HIG
[2]   Outcomes of a major research on fire resistance of concrete columns [J].
Ali, F ;
Nadjai, A ;
Silcock, G ;
Abu-Tair, A .
FIRE SAFETY JOURNAL, 2004, 39 (06) :433-445
[3]   Explosive spalling of high-strength concrete columns in fire [J].
Ali, FA ;
O'Connor, D ;
Abu-Tair, A .
MAGAZINE OF CONCRETE RESEARCH, 2001, 53 (03) :197-204
[4]  
[Anonymous], 2014, 812310 SS
[5]  
[Anonymous], 2012, 13631 EN
[6]  
[Anonymous], 2005, EN 14651 Test method for metallic fibre concrete-Measuring the flexural tensile strength (limit of proportionality (LOP), residual)
[7]  
[Anonymous], 2019, 12350 EN
[8]  
[Anonymous], 2013, BULLETINS FIB, V65/66
[9]  
[Anonymous], 2001, CONSEC 01 3 INT C CO
[10]  
Bazant Z., 1997, NIST SPECIAL PUBLICA, V919, P155