Adaptation and applications of a realistic digital phantom based on patient lung tumor trajectories

被引:20
作者
Mishra, Pankaj [1 ,2 ]
St James, Sara [1 ,2 ]
Segars, W. Paul [3 ]
Berbeco, Ross I. [1 ,2 ]
Lewis, John H. [1 ,2 ]
机构
[1] Brigham & Womens Hosp, Dana Farber Canc Inst, Boston, MA 02115 USA
[2] Harvard Univ, Sch Med, Boston, MA USA
[3] Duke Univ, Dept Radiol, Durham, NC 27710 USA
关键词
COMPUTED-TOMOGRAPHY SIMULATION; 4D XCAT PHANTOM; HUMAN ANATOMY; CT; MOTION;
D O I
10.1088/0031-9155/57/11/3597
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Digital phantoms continue to play a significant role in modeling and characterizing medical imaging. The currently available XCAT phantom incorporates both the flexibility of mathematical phantoms and the realistic nature of voxelized phantoms. This phantom generates images based on a regular breathing pattern and can include arbitrary lung tumor trajectories. In this work, we present an algorithm that modifies the current XCAT phantom to generate 4D imaging data based on irregular breathing. First, a parameter is added to the existing XCAT phantom to include any arbitrary tumor motion. This modification introduces the desired tumor motion but, comes at the cost of decoupled diaphragm, chest wall and lung motion. To remedy this problem diaphragm and chest wall motion is first modified based on initial tumor location and then input to the XCAT phantom. This generates a phantom with synchronized respiratory motion. Mapping of tumor motion trajectories to diaphragm and chest wall motion is done by adaptively calculating a scale factor based on tumor to lung contour distance. The distance is calculated by projecting the initial tumor location to lung edge contours characterized by quadratic polynomials. Data from ten patients were used to evaluate the accuracy between actual independent tumor location and the location obtained from the modified XCAT phantom. The RMSE and standard deviations for ten patients in x, y, and z directions are: (0.29 +/- 0.04, 0.54 +/- 0.17, and 0.39 +/- 0.06) mm. To demonstrate the utility of the phantom, we use the new phantom to simulate a 4DCT acquisition as well as a recently published method for phase sorting. The modified XCAT phantom can be used to generate more realistic imaging data for enhanced testing of algorithms for CT reconstruction, tumor tracking, and dose reconstruction.
引用
收藏
页码:3597 / 3608
页数:12
相关论文
共 22 条
[1]   Towards fluoroscopic respiratory gating for lung tumours without radiopaque markers [J].
Berbeco, RI ;
Mostafavi, H ;
Sharp, GC ;
Jiang, SB .
PHYSICS IN MEDICINE AND BIOLOGY, 2005, 50 (19) :4481-4490
[3]   Voxel-based computational models of real human anatomy: a review [J].
Caon, M .
RADIATION AND ENVIRONMENTAL BIOPHYSICS, 2004, 42 (04) :229-235
[4]   Artifacts in computed tomography scanning of moving objects [J].
Chen, GTY ;
Kung, JH ;
Beaudette, KP .
SEMINARS IN RADIATION ONCOLOGY, 2004, 14 (01) :19-26
[5]   Respiration-correlated spiral CT: A method of measuring respiratory-induced anatomic motion for radiation treatment planning [J].
Ford, EC ;
Mageras, GS ;
Yorke, E ;
Ling, CC .
MEDICAL PHYSICS, 2003, 30 (01) :88-97
[6]   Computed tomography simulation using supertoroids [J].
Hu, Yingkang ;
Zhu, Jiehua .
JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2010, 18 (01) :1-13
[7]   GATE:: a simulation toolkit for PET and SPECT [J].
Jan, S ;
Santin, G ;
Strul, D ;
Staelens, S ;
Assié, K ;
Autret, D ;
Avner, S ;
Barbier, R ;
Bardiès, M ;
Bloomfield, PM ;
Brasse, D ;
Breton, V ;
Bruyndonckx, P ;
Buvat, I ;
Chatziioannou, AF ;
Choi, Y ;
Chung, YH ;
Comtat, C ;
Donnarieix, D ;
Ferrer, L ;
Glick, SJ ;
Groiselle, CJ ;
Guez, D ;
Honore, PF ;
Kerhoas-Cavata, S ;
Kirov, AS ;
Kohli, V ;
Koole, M ;
Krieguer, M ;
van der Laan, DJ ;
Lamare, F ;
Largeron, G ;
Lartizien, C ;
Lazaro, D ;
Maas, MC ;
Maigne, L ;
Mayet, F ;
Melot, F ;
Merheb, C ;
Pennacchio, E ;
Perez, J ;
Pietrzyk, U ;
Rannou, FR ;
Rey, M ;
Schaart, DR ;
Schmidtlein, CR ;
Simon, L ;
Song, TY ;
Vieira, JM ;
Visvikis, D .
PHYSICS IN MEDICINE AND BIOLOGY, 2004, 49 (19) :4543-4561
[8]   Radiotherapy of mobile tumors [J].
Jiang, Steve B. .
SEMINARS IN RADIATION ONCOLOGY, 2006, 16 (04) :239-248
[9]   The management of respiratory motion in radiation oncology report of AAPM Task Group 76 [J].
Keall, Paul J. ;
Mageras, Gig S. ;
Balter, James M. ;
Emery, Richard S. ;
Forster, Kenneth M. ;
Jiang, Steve B. ;
Kapatoes, Jeffrey M. ;
Low, Daniel A. ;
Murphy, Martin J. ;
Murray, Brad R. ;
Ramsey, Chester R. ;
Van Herk, Marcel B. ;
Vedam, S. Sastry ;
Wong, John W. ;
Yorke, Ellen .
MEDICAL PHYSICS, 2006, 33 (10) :3874-3900
[10]   MAX06 and FAX06: update of two adult human phantoms for radiation protection dosimetry [J].
Kramer, R. ;
Khoury, H. J. ;
Vieira, J. W. ;
Lima, V. J. M. .
PHYSICS IN MEDICINE AND BIOLOGY, 2006, 51 (14) :3331-3346