Ultra-Low Flow Electrospray Ionization-Mass Spectrometry for Improved Ionization Efficiency in Phosphoproteomics

被引:81
作者
Heemskerk, Anthonius A. M. [1 ]
Busnel, Jean-Marc [1 ,2 ]
Schoenmaker, Bart [1 ]
Derks, Rico J. E. [1 ]
Klychnikov, Oleg [1 ]
Hensbergen, Paul J. [1 ]
Deelder, Andre M. [1 ]
Mayboroda, Oleg A. [1 ]
机构
[1] Leiden Univ, Med Ctr, Dept Parasitol, Biomol Mass Spectrometry Unit, Leiden, Netherlands
[2] Beckman Coulter Inc, Brea, CA 92821 USA
关键词
CAPILLARY-ZONE-ELECTROPHORESIS; ION-SOURCE; ESI-MS; INTERFACE; SUPPRESSION; PEPTIDE; TIME;
D O I
10.1021/ac300641x
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The potential benefits of ultra-low flow electrospray ionization (ESI) for the analysis of phosphopeptides in proteomics was investigated. First, the relative flow dependent ionization efficiency of nonphosphorylated vs multiplyphosphorylated peptides was characterized by infusion of a five synthetic peptide mix with zero to four phophorylation sites at flow rates ranging from 4.5 to 500 nL/min. Most importantly, similar to what was found earlier by Schmidt et al., it has been verified that, at flow rates below 20 nL/min the relative peak intensities for the various peptides show a trend toward an equimolar response, which would be highly beneficial in phosphoproteomic analysis. As the technology to achieve liquid chromatography separation at flow rates below 20 nL/min is not readily available, a sheathless capillary electrophoresis-electrospray ionization-mass spectrometry (CE-ESI-MS) strategy based on the use of a neutrally coated separation capillary was used to develop an analytical strategy at flow rates as low as 6.6 nL/min. An in-line preconcentration technique, namely, transient isotachophoresis (t-ITP), to achieve efficient separation while using larger volume injections (37% of capillary thus 250 nL) was incorporated to achieve even greater sample concentration sensitivities. The developed t-ITP-ESI-MS strategy was then used in a direct comparison with nano-LC-MS for the detection of phosphopeptides. The comparison showed significantly improved phosphopeptide sensitivity in equal sample load and equal sample concentration conditions for CE-MS while providing complementary data to LC-MS, demonstrating the potential of ultra-low flow ESI for the analysis of phosphopeptides in liquid based separation techniques.
引用
收藏
页码:4552 / 4559
页数:8
相关论文
共 34 条
  • [1] Ion suppression in mass spectrometry
    Annesley, TM
    [J]. CLINICAL CHEMISTRY, 2003, 49 (07) : 1041 - 1044
  • [2] Glycoform characterization of erythropoietin combining glycan and intact protein analysis by capillary electrophoresis electrospray time-of-flight mass spectrometry
    Balaguer, Elvira
    Demelbauer, Uwe
    Pelzing, Matthias
    Sanz-Nebot, Victoria
    Barbosa, Jose
    Neusuess, Christian
    [J]. ELECTROPHORESIS, 2006, 27 (13) : 2638 - 2650
  • [3] CAPILLARY ELECTROPHORESIS INSTRUMENTATION AS A BENCH-TOP VISCOMETER
    BELLO, MS
    REZZONICO, R
    RIGHETTI, PG
    [J]. JOURNAL OF CHROMATOGRAPHY A, 1994, 659 (01) : 199 - 204
  • [4] IMMOBILIZED-METAL AFFINITY CHROMATOGRAPHY (IMAC): A REVIEW
    Block, Helena
    Maertens, Barbara
    Spriestersbach, Anne
    Brinker, Nicole
    Kubicek, Jan
    Fabis, Roland
    Labahn, Joerg
    Schaefer, Frank
    [J]. GUIDE TO PROTEIN PURIFICATION, SECOND EDITION, 2009, 463 : 439 - 473
  • [5] High Capacity Capillary Electrophoresis-Electrospray Ionization Mass Spectrometry: Coupling a Porous Sheathless Interface with Transient-Isotachophoresis
    Busnel, Jean-Marc
    Schoenmaker, Bart
    Ramautar, Rawi
    Carrasco-Pancorbo, Alegria
    Ratnayake, Chitra
    Feitelson, Jerald S.
    Chapman, Jeff D.
    Deelder, Andre M.
    Mayboroda, Oleg A.
    [J]. ANALYTICAL CHEMISTRY, 2010, 82 (22) : 9476 - 9483
  • [6] Iontophoretic Fraction Collection for Coupling Capillary Zone Electrophoresis with Matrix-Assisted Laser Desorption/Ionization Mass Spectrometry
    Busnel, Jean-Marc
    Josserand, Jacques
    Lion, Niels
    Girault, Hubert H.
    [J]. ANALYTICAL CHEMISTRY, 2009, 81 (10) : 3867 - 3872
  • [7] Predicting electrospray response from chromatographic retention time
    Cech, NB
    Krone, JR
    Enke, CG
    [J]. ANALYTICAL CHEMISTRY, 2001, 73 (02) : 208 - 213
  • [8] ELECTROSPRAY IONIZATION FOR MASS-SPECTROMETRY OF LARGE BIOMOLECULES
    FENN, JB
    MANN, M
    MENG, CK
    WONG, SF
    WHITEHOUSE, CM
    [J]. SCIENCE, 1989, 246 (4926) : 64 - 71
  • [9] Improved Electrospray Ionization Efficiency Compensates for Diminished Chromatographic Resolution and Enables Proteomics Analysis of Tyrosine Signaling in Embryonic Stem Cells
    Ficarro, Scott B.
    Zhang, Yi
    Lu, Yu
    Moghimi, Ahmadali R.
    Askenazi, Manor
    Hyatt, Elzbieta
    Smith, Eric D.
    Boyer, Leah
    Schlaeger, Thorsten M.
    Luckey, C. John
    Marto, Jarrod A.
    [J]. ANALYTICAL CHEMISTRY, 2009, 81 (09) : 3440 - 3447
  • [10] Reduction of signal suppression effects in ESI-MS using a nanosplitting device
    Gangl, ET
    Annan, M
    Spooner, N
    Vouros, P
    [J]. ANALYTICAL CHEMISTRY, 2001, 73 (23) : 5635 - 5644