Fetal Imaging with Dynamic Electrical Impedance Tomography Technique

被引:0
|
作者
Konki, Sravan Kumar [1 ]
Khambampati, Anil Kumar [2 ]
Kim, Kyung Youn [3 ]
机构
[1] Jeju Natl Univ, Fac Appl Energy Syst, Major Elect Engn, Jeju 63243, South Korea
[2] Jeju Natl Univ, BK21 Clean Energy Convergence & Integrat Ctr Huma, Jeju 63243, South Korea
[3] Jeju Natl Univ, Dept Elect Engn, Jeju 63243, South Korea
关键词
Fetal Movements; Electrical Impedance Tomography; Finite Element Method; Image Reconstruction; Extended Kalman Filter; MOVEMENTS;
D O I
10.1166/jmihi.2019.2569
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
The fetal movements are the primary parameters that are clinically significant for determining the fetal growth and well-being during pregnancy. Conventional methods such as ultrasound, magnetocardiography are expensive and cannot be used for continuous monitoring. Moreover, to operate the instruments and analyze the images, they need experts. For a better healthy pregnancy outcome, an appropriate, portable, low cost, non-invasive and continuous imaging technique is essential to reconstruct the fetal movements inside abdomen during pregnancy. As an alternative method, electrical impedance tomography can be used as a continuous fetal monitoring imaging tool. This work introduces dynamic electrical impedance tomography (EIT) imaging technique to reconstruct the fetus movements inside abdomen. Dynamic EIT is a non-invasive and non-ionizing imaging modality that can estimate and reconstruct the time varying conductivity distribution of fetus inside pregnant women by injecting a small magnitude of electrical currents through the skin electrodes placed on the surface of the abdomen and measuring the resulting voltages across the electrodes. The problem of estimating the time varying fetus conductivity distribution due to fetal movement is treated as a state estimation problem and the state variables are the conductivity of finite elements that are discretized across the abdomen. Extended Kalman filtering method is used as an inverse algorithm to estimate the time varying state variables. Numerical simulations with abdomen shaped mesh and phantom studies are done to verify the feasibility of dynamic EIT system for fetus monitoring.
引用
收藏
页码:23 / 31
页数:9
相关论文
共 50 条
  • [21] Electrical impedance tomography for high speed chest imaging
    Lionheart, WRB
    Lidgey, FJ
    McLeod, CN
    Paulson, KS
    Pidcock, MK
    Shi, Y
    PHYSICA MEDICA, 1997, 13 : 247 - 249
  • [22] A review on electrical impedance tomography for pulmonary perfusion imaging
    Nguyen, D. T.
    Jin, C.
    Thiagalingam, A.
    McEwan, A. L.
    PHYSIOLOGICAL MEASUREMENT, 2012, 33 (05) : 695 - 706
  • [23] Single Cell Imaging Using Electrical Impedance Tomography
    Sun, Tao
    Tsuda, Soichiro
    Zauner, Klaus-Peter
    Morgan, Hywel
    2009 4TH IEEE INTERNATIONAL CONFERENCE ON NANO/MICRO ENGINEERED AND MOLECULAR SYSTEMS, VOLS 1 AND 2, 2009, : 858 - 863
  • [24] Electrical impedance tomography imaging of epileptic activity in humans
    Eadie, L
    Bagshaw, A
    Bayford, R
    Binnie, C
    Holder, D
    NEUROIMAGE, 2001, 13 (06) : S1314 - S1314
  • [25] Capacitively Coupled Electrical Impedance Tomography in Lung Imaging
    Guo, Yuxi
    Zhu, Liying
    Wang, Minmin
    Jiang, Yandan
    Soleimani, Manuchehr
    Zhang, Maomao
    IEEE SENSORS JOURNAL, 2024, 24 (20) : 33072 - 33082
  • [26] Fast imaging for magnetic resonance electrical impedance tomography
    Hamamura, Mark J.
    Muftuler, L. Tugan
    MAGNETIC RESONANCE IMAGING, 2008, 26 (06) : 739 - 745
  • [27] Imaging heterogeneities with electrical impedance tomography: laboratory results
    Borsic, A
    Comina, C
    Foti, S
    Lancellotta, R
    Musso, G
    GEOTECHNIQUE, 2005, 55 (07): : 539 - 547
  • [28] Practical reconstruction algorithm of dynamic electrical impedance tomography
    Dong, Xiuzhen
    Qin, Mingxin
    Tang, Mengxing
    Fu, Feng
    Shi, Xuetao
    You, Fusheng
    Zhongguo Shengwu Yixue Gongcheng Xuebao/Chinese Journal of Biomedical Engineering, 2000, 19 (03): : 348 - 352
  • [29] Reconstruction and Imaging of Intracerebral Hemorrhage by Electrical Impedance Tomography
    Wang, L.
    Liu, W. B.
    Yu, X.
    Dong, X. Z.
    Gao, F.
    2017 10TH INTERNATIONAL CONGRESS ON IMAGE AND SIGNAL PROCESSING, BIOMEDICAL ENGINEERING AND INFORMATICS (CISP-BMEI), 2017,
  • [30] Dynamic electrical impedance tomography with known internal structures
    Kim, KY
    Kang, SI
    Kim, MC
    Kim, S
    Lee, YJ
    Vauhkonen, M
    INVERSE PROBLEMS IN ENGINEERING, 2003, 11 (01): : 1 - 19