Effects of flow changes on radiotracer binding: Simultaneous measurement of neuroreceptor binding and cerebral blood flow modulation

被引:22
|
作者
Sander, Christin Y. [1 ,2 ]
Mandeville, Joseph B. [1 ,2 ]
Wey, Hsiao-Ying [1 ,2 ]
Catana, Ciprian [1 ,2 ]
Hooker, Jacob M. [1 ,2 ]
Rosen, Bruce R. [1 ,2 ,3 ]
机构
[1] Massachusetts Gen Hosp, Athinoula A Martinos Ctr Biomed Imaging, Dept Radiol, Charlestown, MA USA
[2] Harvard Med Sch, Boston, MA USA
[3] Harvard MIT, Hlth Sci & Technol, Cambridge, MA USA
来源
关键词
Cerebral blood flow; dopamine receptor imaging; pharmacokinetic modeling; positron emission tomography; functional magnetic resonance imaging; POSITRON-EMISSION-TOMOGRAPHY; REFERENCE TISSUE MODEL; EXTRASTRIATAL DOPAMINE RELEASE; RECEPTOR-BINDING; PET MEASUREMENT; TEST-RETEST; BASE-LINE; IN-VIVO; BRAIN; FMRI;
D O I
10.1177/0271678X17725418
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The potential effects of changes in blood flow on the delivery and washout of radiotracers has been an ongoing question in PET bolus injection studies. This study provides practical insight into this topic by experimentally measuring cerebral blood flow (CBF) and neuroreceptor binding using simultaneous PET/MRI. Hypercapnic challenges (7% CO2) were administered to non-human primates in order to induce controlled increases in CBF, measured with pseudo-continuous arterial spin labeling. Simultaneously, dopamine D-2/D-3 receptor binding of [C-11]raclopride or [F-18]fallypride was monitored with dynamic PET. Experiments showed that neither time activity curves nor quantification of binding through binding potentials (BPND) were measurably affected by CBF increases, which were larger than two-fold. Simulations of experimental procedures showed that even large changes in CBF should have little effect on the time activity curves of radiotracers, given a set of realistic assumptions. The proposed method can be applied to experimentally assess the flow sensitivity of other radiotracers. Results demonstrate that CBF changes, which often occur due to behavioral tasks or pharmacological challenges, do not affect PET [C-11]raclopride or [F-18]fallypride binding studies and their quantification. The results from this study suggest flow effects may have limited impact on many PET neuroreceptor tracers with similar properties.
引用
收藏
页码:131 / 146
页数:16
相关论文
共 50 条
  • [1] Transient modulation of cerebral blood flow does not alter [11C]PBR28 radiotracer binding
    Sander, C. Y.
    Torrado-Carvajal, A.
    Bovo, S.
    Hooker, J. M.
    Loggia, M.
    JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 2019, 39 : 605 - 606
  • [2] EFFECTS OF HYPERCARBIA ON CANINE CEREBRAL METABOLISM AND BLOOD-FLOW WITH SIMULTANEOUS DIRECT AND INDIRECT MEASUREMENT OF BLOOD-FLOW
    ARTRU, AA
    MICHENFELDER, JD
    ANESTHESIOLOGY, 1980, 52 (06) : 466 - 469
  • [3] RADIOTRACER MEASUREMENT OF URETERAL BLOOD-FLOW
    MOONEY, EF
    GERAGHTY, JG
    OCONNELL, M
    KENT, P
    ANGERSON, W
    QUERESHI, A
    SARAZEN, A
    FITZPATRICK, JM
    JOURNAL OF UROLOGY, 1994, 152 (03): : 1022 - 1024
  • [4] MEASUREMENT OF LOCAL CEREBRAL BLOOD FLOW BY IMPEDANCE CHANGES
    BIRZIS, L
    TACHIBANA, S
    LIFE SCIENCES, 1962, (11) : 587 - 598
  • [5] MEASUREMENT OF CEREBRAL BLOOD FLOW
    MCHENRY, LC
    NEW ENGLAND JOURNAL OF MEDICINE, 1965, 273 (10): : 562 - &
  • [6] Simultaneous PET-MRI Confirms That Cerebral Blood Flow Does Not Confound PET Neuroreceptor Activation Studies
    Nummenmaa, Lauri
    Tuominen, Lauri
    Hirvonen, Jussi
    ACS CHEMICAL NEUROSCIENCE, 2018, 9 (02): : 159 - 161
  • [7] THE SIMULTANEOUS MEASUREMENT OF REGIONAL CEREBRAL BLOOD-FLOW AND OXYGEN UTILIZATION
    LAMMERTSMA, AA
    FRACKOWIAK, RSJ
    HUANG, SC
    PHELPS, ME
    JONES, T
    JOURNAL OF NUCLEAR MEDICINE, 1986, 27 (06) : 913 - 913
  • [8] CEREBRAL BLOOD-FLOW METHODS FOR MEASUREMENT REGULATION, EFFECTS OF DRUGS AND CHANGES IN DISEASE
    OLESEN, J
    ACTA NEUROLOGICA SCANDINAVICA, 1974, 50 (M 57): : 1 - 134
  • [9] Cholinergic modulation of cerebral cortical blood flow changes induced by trauma
    Scremin, OU
    Li, MG
    Jenden, DJ
    JOURNAL OF NEUROTRAUMA, 1997, 14 (08) : 573 - 586
  • [10] A DUAL LABEL RADIOTRACER TECHNIQUE FOR THE SIMULTANEOUS MEASUREMENT OF CEREBRAL BLOOD-FLOW AND THE SINGLE-TRANSIT CEREBRAL EXTRACTION OF DIFFUSION-LIMITED COMPOUNDS IN RATS
    IRWIN, GH
    PRESKORN, SH
    BRAIN RESEARCH, 1982, 249 (01) : 23 - 30