Four-dimensional flow-sensitive MRI of the thoracic aorta: 12-versus 32-channel coil arrays

被引:14
作者
Stalder, Aurelien F. [1 ,2 ]
Dong, Zhiyuan [1 ]
Yang, Qi [1 ]
Bock, Jelena [2 ]
Hennig, Juergen [2 ]
Markl, Michael [2 ]
Li, Kuncheng [1 ]
机构
[1] Capital Med Univ, Xuanwu Hosp, Dept Radiol, Beijing 100053, Peoples R China
[2] Univ Hosp, Dept Radiol Med Phys, Freiburg, Germany
关键词
phase-contrast MRI; 4D flow-sensitive MRI; aorta; parallel imaging; 32-channel coil; GRAPPA; PHASE-CONTRAST MRI; TO-NOISE RATIO; BLOOD-FLOW; MAGNETIC-RESONANCE; VELOCITY-MEASUREMENTS; CARDIAC COIL; TESLA; STREAMLINES; ANGIOGRAPHY; COARCTATION;
D O I
10.1002/jmri.22633
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To evaluate the performance of four-dimensional (4D) flow-sensitive MRI in the thoracic aorta using 12- and 32-channel coils and parallel imaging. Materials and Methods: 4D flow-sensitive MRI was performed in the thoracic aorta of 11 healthy volunteers at 3 Tesla (T) using different coils and parallel imaging (GRAPPA) accelerations (R): (i) 12-channel coil, R = 2; (ii) 12-channel coil, R = 3; (iii) 32-channel coil, R = 3. The quantitative analysis included SNR, residual velocity divergence and length and curvature of traces (streamlines and pathlines) as used for 3D flow visualization. In addition, semi-quantitative image grading was performed to assess quality of phase-contrast angiography and 3D flow visualization. Results: Parallel imaging with an acceleration factor R = 3 allowed to save 19.5 +/- 5% measurement time compared with R = 2 (14.2 +/- 2.4 min). Acquisition using 12 channels with R = 2 and 32 channels with R = 3 produced data with significantly (P < 0.05) higher quality compared with 12 channels and R = 3. There was no significant difference between 12 channels with R = 2 and 32 channels with R = 3 but for the depiction of supra-aortic branches where the 32-channel coil proved superior. Conclusion: Using 32-channel coils is beneficial for 4D flow-sensitive MRI of the thoracic aorta and can allow for a reduction of total scan time while maintaining overall image quality.
引用
收藏
页码:190 / 195
页数:6
相关论文
共 21 条
[1]   Time-resolved 3D quantitative flow MRI of the major intracranial vessels: Initial experience and comparative evaluation at 1.5T and 3.0T in combination with parallel imaging [J].
Bammer, Roland ;
Hope, Thomas A. ;
Aksoy, Murat ;
Alley, Marcus T. .
MAGNETIC RESONANCE IN MEDICINE, 2007, 57 (01) :127-140
[2]   Concomitant gradient terms in phase contrast MR: Analysis and correction [J].
Bernstein, MA ;
Zhou, XHJ ;
Polzin, JA ;
King, KF ;
Ganin, A ;
Pelc, NJ ;
Glover, GH .
MAGNETIC RESONANCE IN MEDICINE, 1998, 39 (02) :300-308
[3]   4D Phase Contrast MRI at 3 T: Effect of Standard and Blood-Pool Contrast Agents on SNR, PC-MRA, and Blood Flow Visualization [J].
Bock, Jelena ;
Frydrychowicz, Alex ;
Stalder, Aurelien F. ;
Bley, Thorsten A. ;
Burkhardt, Hans ;
Hennig, Juergen ;
Markl, Michael .
MAGNETIC RESONANCE IN MEDICINE, 2010, 63 (02) :330-338
[4]   MAGNETIC-RESONANCE VELOCITY VECTOR MAPPING OF BLOOD-FLOW IN THORACIC AORTIC-ANEURYSMS AND GRAFTS [J].
BOGREN, HG ;
MOHIADDIN, RH ;
YANG, GZ ;
KILNER, PJ ;
FIRMIN, DN .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1995, 110 (03) :704-714
[5]   ALGORITHMS FOR IMPROVING CALCULATED STREAMLINES IN 3-D PHASE-CONTRAST ANGIOGRAPHY [J].
BUONOCORE, MH .
MAGNETIC RESONANCE IN MEDICINE, 1994, 31 (01) :22-30
[6]  
Emanuel G., 2001, Analytical Fluid Dynamics, Vsecond
[7]  
FLEISS JL, 1971, PSYCHOL BULL, V76, P378, DOI 10.1037/h0031619
[8]   Time-resolved magnetic resonance angiography and flow-sensitive 4-dimensional magnetic resonance imaging at 3 Tesla for blood flow and wall shear stress analysis [J].
Frydrychowicz, Alex ;
Berger, Alexander ;
Russe, Maximilan F. ;
Stalder, Aurelien F. ;
Harloff, Andreas ;
Dittrich, Sven ;
Hennig, Juergen ;
Langer, Mathias ;
Markl, Michael .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2008, 136 (02) :400-407
[9]   Multidirectional flow analysis by cardiovascular magnetic resonance in aneurysm development following repair of aortic coarctation [J].
Frydrychowicz, Alex ;
Arnold, Raoul ;
Hirtler, Daniel ;
Schlensak, Christian ;
Stalder, Aurelien F. ;
Hennig, Juergen ;
Langer, Mathias ;
Markl, Michael .
JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2008, 10 (1)
[10]   Generalized Autocalibrating Partially Parallel Acquisitions (GRAPPA) [J].
Griswold, MA ;
Jakob, PM ;
Heidemann, RM ;
Nittka, M ;
Jellus, V ;
Wang, JM ;
Kiefer, B ;
Haase, A .
MAGNETIC RESONANCE IN MEDICINE, 2002, 47 (06) :1202-1210