Field assessment of a new membrane-free microelectrode dissolved oxygen sensor for water column profiling

被引:10
作者
Sosna, Maciej [1 ]
Denuault, Guy [1 ]
Pascal, Robin W. [2 ]
Prien, Ralf D.
Mowlem, Matt [2 ]
机构
[1] Univ Southampton, Sch Chem, Southampton SO17 1BJ, Hants, England
[2] Univ Southampton, Natl Oceanog Ctr, Southampton SO14 3ZH, Hants, England
关键词
D O I
10.4319/lom.2008.6.180
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
This article reports on the field trials of a membrane-free amperometric microelectrode dissolved oxygen sensor, which were performed during oceanographic cruise D279 of RRS Discovery. The sensor was used to obtain full depth oxygen profiles while mounted on a wire-operated CTD (conductivity, temperature, depth) instrument. A stable performance was achieved by carefully designed electrochemical cleaning conditions of the sensing platinum microdisk cathode. The flow issues inherent to moving probes were resolved by a novel stop-flow cell fitted with a pumping system for sample exchange and flow control. The details of the sensor operation, calibration, and construction, including the flow control system, are described. The sensor response is validated by calibration and by an analytical approach that yields oxygen data directly from the current readings. The accuracy of the microelectrode response is critically assessed using Winkler titrations on bottle samples taken during the relevant sensor deployments. The results lead to the conclusion that due to high accuracy, fast response time, and lack of membrane-related problems the device is particularly suitable for moving probes and high spatial resolution water column oxygen profiling.
引用
收藏
页码:180 / 189
页数:10
相关论文
共 43 条
[1]  
*ACT, 2006, DISS OXYG PROB MAK O
[2]   DIFFUSIVITIES OF GASES IN AQUEOUS-ELECTROLYTE SOLUTIONS [J].
AKITA, K .
INDUSTRIAL & ENGINEERING CHEMISTRY FUNDAMENTALS, 1981, 20 (01) :89-94
[3]   DIRECT MEASUREMENT OF THE DIFFUSIVE SUBLAYER AT THE DEEP-SEA FLOOR USING OXYGEN MICROELECTRODES [J].
ARCHER, D ;
EMERSON, S ;
SMITH, CR .
NATURE, 1989, 340 (6235) :623-626
[4]   FAST-RESPONSE OXYGEN SENSOR FOR A FREE-FALL CTD [J].
ATKINSON, MJ .
LIMNOLOGY AND OCEANOGRAPHY, 1988, 33 (01) :141-145
[5]  
Atkinson MJ, 1996, J ATMOS OCEAN TECH, V13, P1267, DOI 10.1175/1520-0426(1996)013<1267:EOPOOS>2.0.CO
[6]  
2
[7]   A MICRO-HOLE POTENTIOSTATIC OXYGEN SENSOR FOR OCEANIC CTDS [J].
ATKINSON, MJ ;
THOMAS, FIM ;
LARSON, N ;
TERRILL, E ;
MORITA, K ;
LIU, CC .
DEEP-SEA RESEARCH PART I-OCEANOGRAPHIC RESEARCH PAPERS, 1995, 42 (05) :761-&
[8]   DEVELOPMENT OF A GOLD AMALGAM VOLTAMMETRIC MICROELECTRODE FOR THE DETERMINATION OF DISSOLVED FE, MN, O-2, AND S(-II) IN POREWATERS OF MARINE AND FRESH-WATER SEDIMENTS [J].
BRENDEL, PJ ;
LUTHER, GW .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1995, 29 (03) :751-761
[9]   CONTINUOUS RECORDING OF BLOOD OXYGEN TENSIONS BY POLAROGRAPHY [J].
CLARK, LC ;
WOLF, R ;
GRANGER, D ;
TAYLOR, Z .
JOURNAL OF APPLIED PHYSIOLOGY, 1953, 6 (03) :189-193
[10]   Chemical and biological sensors for time-series research: Current status and new directions [J].
Daly, KL ;
Byrne, RH ;
Dickson, AG ;
Gallager, SM ;
Perry, MJ ;
Tivey, MK .
MARINE TECHNOLOGY SOCIETY JOURNAL, 2004, 38 (02) :121-143