Efficacy of Colloidal Silver-Hydrogen Peroxide and 2-Bromo-2-nitroporopane-1,3-diol Compounds Against Different Serogroups of Legionella pneumophila Strains

被引:1
作者
Sanli-Yurudu, N. O. [1 ]
Kimiran-Erdem, A. [1 ]
Arslan-Aydogdu, E. O. [1 ]
Zeybek, Z. [1 ]
Gurun, S. [1 ]
机构
[1] Istanbul Univ, Dept Biol, Sect Fundamental & Ind Microbiol, Fac Sci, TR-34134 Istanbul, Turkey
关键词
Legionella pneumophila; Biocide; Cooling tower; COOLING-TOWERS; SESSILE POPULATIONS; WATER-SYSTEMS; DISINFECTANTS; BIOCIDES; SUSCEPTIBILITY; CHLORAMINE;
D O I
10.1007/s12088-011-0189-z
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Cooling towers are considered as amplifier and disseminator sources for Legionella spp. despite preventive treatments. Information which was obtained from biocidal tests could improve the effectiveness of treatments. Therefore, the choice of appropriate biocides and the applying of biocides in correct dosages and contact times are important. Various oxidizing and non-oxidizing biocides have been investigated in vitro for their effectiveness against legionellae. Colloidal silver-hydrogen peroxide (CSHP) and 2-bromo-2-nitroporopane-1,3-diol (BNPD) biocides were selected as an example for oxidizing and non-oxidizing agents, respectively, in view of bactericidal action against different serogroups of L. pneumophila strains [ serogroup 1 (S1) and serogroup 2-14 (S2)] which are isolated different cooling towers in the vicinity of Istanbul, Turkey and reference strain. In the current study, oxidizing biocide was found more effective than non-oxidizing biocide in terms of contact times, log reductions and recommended dosages. At the recommended concentrations for cooling towers (100 ppm), while CSHP compound killed all strains in 3 h contact time, BNPD compound killed S2 and reference strain in the same contact time, S1 strain after 6 h contact time. The results of the present study showed that effective biocide applications can be achieved by pre-determining minimum inhibitory concentration (MIC) and minimum contact time of different biocides to kill target bacteria.
引用
收藏
页码:54 / 59
页数:6
相关论文
共 24 条
  • [21] INACTIVATION OF LEGIONELLA-PNEUMOPHILA BY HYPOCHLORITE AND AN ORGANIC CHLORAMINE
    SWANGO, LJ
    WILT, GR
    KILLEN, AD
    WILLIAMS, DE
    WORLEY, SD
    [J]. APPLIED AND ENVIRONMENTAL MICROBIOLOGY, 1987, 53 (12) : 2983 - 2986
  • [22] DECREASED BIOCIDE SUSCEPTIBILITY OF ADHERENT LEGIONELLA-PNEUMOPHILA
    WRIGHT, JB
    RUSESKA, I
    COSTERTON, JW
    [J]. JOURNAL OF APPLIED BACTERIOLOGY, 1991, 71 (06): : 531 - 538
  • [23] EFFECTS OF BIOCIDAL TREATMENTS TO INHIBIT THE GROWTH OF LEGIONELLAE AND OTHER MICROORGANISMS IN COOLING-TOWERS
    YAMAMOTO, H
    EZAKI, T
    IKEDO, M
    YABUUCHI, E
    [J]. MICROBIOLOGY AND IMMUNOLOGY, 1991, 35 (09) : 795 - 802
  • [24] Profiling of environmental Legionella pneumophila strains by randomly amplified polymorphic DNA method isolated from geographically nearby buildings
    Zeybek, Z.
    Turetgen, Irfan
    Erdem, Ayten Kimiran
    Filoglu, Goenuel
    Cotuk, Aysin