Wear-resistant, hemocompatible Ti-Nb-Zr and Zr-Nb alloys to improve blood pump design and performance

被引:9
作者
Davidson, JA [1 ]
Daigle, KP [1 ]
Kovacs, P [1 ]
机构
[1] SMITH & NEPHEW RICHARDS INC,MEMPHIS,TN
关键词
blood pumps; Ti-13Nb-13Zr; Zr alloy; wear; ceramic; hemocompatibility;
D O I
10.1111/j.1525-1594.1996.tb04473.x
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Over the past several years, we have developed novel titanium-niobium-zirconium (Ti-Nb-Zr) alloys to address the long-term performance needs of orthopedic implants. The unique properties of these alloys also render them promising candidates for blood pumps. These properties include excellent biocompatibility in combination with high strength and toughness, and low elastic modulus (low stiffness). Additionally, these metal alloys are readily hot or cold worked into complex shapes including wire, foil, tubing, and bar. They are readily machined and polished, and they can be surface oxidized to form a hard, wear-resistant, low-friction ceramic surface layer. In this diffusion-hardened condition, oxygen also hardens the underlying metal to optimize the bone between the ceramic oxide surface and the tough metal substrate. Unlike metal surfaces, oxidative wear, which can alter surface energy, friction, and hemocompatibility, does not occur. Consequently, the combined benefits of a stable, wear-resistant, low-friction ceramic surface layer with the toughness, strength, formability, and thermal conductivity of metal may provide improvements in the design and performance of blood pumps and peripheral graft and percutaneous (power) components of the pump.
引用
收藏
页码:513 / 522
页数:10
相关论文
共 57 条
[51]   VARIATIONS BETWEEN BIOMER LOTS .2. THE EFFECT OF DIFFERENCES BETWEEN LOTS ON INVITRO ENZYMATIC AND OXIDATIVE-DEGRADATION OF A COMMERCIAL POLYURETHANE [J].
TYLER, BJ ;
RATNER, BD .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1993, 27 (03) :327-334
[52]   BIOCOMPATIBILITY OF WEAR-RESISTANT COATINGS IN ORTHOPEDIC-SURGERY IN-VITRO TESTING WITH HUMAN FIBROBLAST CELL-CULTURES [J].
VANRAAY, JJAM ;
ROZING, PM ;
VANBLITTERSWIJK, CA ;
VANHAASTERT, RM ;
KOERTEN, HK .
JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 1995, 6 (02) :80-84
[53]   CONTACT ACTIVATION OF THE PLASMA COAGULATION CASCADE .1. PROCOAGULANT SURFACE-CHEMISTRY AND ENERGY [J].
VOGLER, EA ;
GRAPER, JC ;
HARPER, GR ;
SUGG, HW ;
LANDER, LM ;
BRITTAIN, WJ .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1995, 29 (08) :1005-1016
[54]   COMPETITIVE-BINDING OF CHROMIUM, COBALT AND NICKEL TO SERUM-PROTEINS [J].
YANG, J ;
BLACK, J .
BIOMATERIALS, 1994, 15 (04) :262-268
[55]   DETECTION OF ANTIBODIES AGAINST CORROSION PRODUCTS IN PATIENTS AFTER CO-CR TOTAL JOINT REPLACEMENTS [J].
YANG, J ;
MERRITT, K .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1994, 28 (11) :1249-1258
[56]  
YUN Y, 1994, THESIS U MEMPHIS LIB
[57]  
YUN YH, 1995, T SOC BIOMATERIALS, V18, P202