Wear-resistant, hemocompatible Ti-Nb-Zr and Zr-Nb alloys to improve blood pump design and performance

被引:9
作者
Davidson, JA [1 ]
Daigle, KP [1 ]
Kovacs, P [1 ]
机构
[1] SMITH & NEPHEW RICHARDS INC,MEMPHIS,TN
关键词
blood pumps; Ti-13Nb-13Zr; Zr alloy; wear; ceramic; hemocompatibility;
D O I
10.1111/j.1525-1594.1996.tb04473.x
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Over the past several years, we have developed novel titanium-niobium-zirconium (Ti-Nb-Zr) alloys to address the long-term performance needs of orthopedic implants. The unique properties of these alloys also render them promising candidates for blood pumps. These properties include excellent biocompatibility in combination with high strength and toughness, and low elastic modulus (low stiffness). Additionally, these metal alloys are readily hot or cold worked into complex shapes including wire, foil, tubing, and bar. They are readily machined and polished, and they can be surface oxidized to form a hard, wear-resistant, low-friction ceramic surface layer. In this diffusion-hardened condition, oxygen also hardens the underlying metal to optimize the bone between the ceramic oxide surface and the tough metal substrate. Unlike metal surfaces, oxidative wear, which can alter surface energy, friction, and hemocompatibility, does not occur. Consequently, the combined benefits of a stable, wear-resistant, low-friction ceramic surface layer with the toughness, strength, formability, and thermal conductivity of metal may provide improvements in the design and performance of blood pumps and peripheral graft and percutaneous (power) components of the pump.
引用
收藏
页码:513 / 522
页数:10
相关论文
共 57 条
[1]  
ASSAD M, 1994, T ORTHOPAEDIC RES SO, V19, P591
[2]  
BABU JP, 1995, T SOC BIOMATERIALS, V18, P73
[3]  
BOKROS JC, 1977, CARBON, V15, P355, DOI 10.1016/0008-6223(77)90324-4
[4]  
BOLZ A, 1993, MED BIOL ENG COMPUT, V31, P43
[5]  
BRASH JL, 1991, BLOOD COMPATIBLE MAT, P11
[6]  
BUCHANAN R, 1987, J BIOMED MATER RES, V21, P377
[7]   INFECTION AT THE SITE OF IMPLANTED MATERIALS WITH AND WITHOUT PREADHERED BACTERIA [J].
CHANG, CC ;
MERRITT, K .
JOURNAL OF ORTHOPAEDIC RESEARCH, 1994, 12 (04) :526-531
[8]   INTRAVASCULAR STENTS [J].
CHAPMAN, GD ;
GAMMON, RS ;
BAUMAN, RP ;
STACK, RS .
TRENDS IN CARDIOVASCULAR MEDICINE, 1991, 1 (03) :127-131
[9]   HEAT-TRANSFER ANALYSIS OF FRICTIONAL HEAT DISSIPATION DURING ARTICULATION OF FEMORAL IMPLANTS [J].
DAVIDSON, JA ;
GIR, S ;
PAUL, JP .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH-APPLIED BIOMATERIALS, 1988, 22 (A3) :281-309
[10]  
DAVIDSON JA, 1994, BIO-MED MATER ENG, V4, P231