Characteristics of X-ray Hot Spots in a 3.5 kJ Plasma Focus Device at Different Pressures of Argon and Air

被引:0
作者
Sanjabad, Masoomeh Shad [1 ]
Bidabadi, Babak Shirani [1 ]
Jabbari, Iraj [1 ]
机构
[1] Univ Isfahan, Fac Adv Sci & Technol, Dept Nucl Engn, Esfahan, Iran
关键词
Hot spot; Plasma focus; X-ray source; Pinhole camera; RADIOGRAPHY; DISCHARGES; MIXTURES; EMISSION; HOTSPOTS;
D O I
10.1007/s10894-017-0130-5
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
The present study examined the formation of hot spots in the plasma column of a 3.5 kJ Mather-type plasma focus device. Experiments were performed with air and argon as operating gases at 0.2-1.5 mbar of pressures. X-ray source images were obtained using a pinhole camera with dental X-ray film as X-ray detector. The objective was to investigate the effect of the operating conditions and gas type on formation and characteristics of the hot spots. Results showed that when using air in comparison to argon, the total X-ray emission is increased and therefore, the hot spots are covered by this high intensity emission and would be observed less frequently in the image. Using metal filters to attenuate the low-energy X-rays revealed that the most energetic or the most intense radiation was emitted from the hot spots region. The images of the X-ray source obtained using argon at the middle pressures (0.4-0.6 mbar) showed both the plasma column and the photons emitted from the anode surface. A pressure of 0.8-1.5 mbar using argon was most likely to observe the hot spots. For argon gas, the 0.9 mbar was the pressure in which the hot spots were more frequently observed with high reproducibility of location and number. Measurements revealed that the typical size of a hot spot was 10-300 mu m and the distance from the anode surface was 0.5-20 mm.
引用
收藏
页码:120 / 126
页数:7
相关论文
共 50 条
  • [21] Study of Pyrex and quartz insulators contamination effect on the X-ray intensity in a 4-kJ plasma focus device
    Habibi, M.
    Sharifi, R.
    Amrollahi, R.
    PLASMA PHYSICS REPORTS, 2013, 39 (12) : 999 - 1003
  • [22] Practical Optimization of AECS PF-2 Plasma Focus Device for Argon Soft X-ray Operation
    Akel, M.
    Lee, S.
    JOURNAL OF FUSION ENERGY, 2012, 31 (02) : 122 - 129
  • [23] Soft X-ray optimization studies on a dense plasma focus device operated in neon and argon in repetitive mode
    Wong, D
    Patran, A
    Tan, TL
    Rawat, RS
    Lee, P
    IEEE TRANSACTIONS ON PLASMA SCIENCE, 2004, 32 (06) : 2227 - 2235
  • [24] Dependence of Soft X-Ray Yield on Plasma Focus Parameters and Its Kinetic and Magnetic Pressures
    El-Sayed, H. A.
    Allam, T. M.
    Ahmed, Kamal M.
    Soliman, H. M.
    PLASMA PHYSICS REPORTS, 2023, 49 (06) : 718 - 724
  • [25] Characterization of soft X-ray radiation from plasma focus device with gas puff
    Kitaoka, H
    Yamamoto, T
    Hirano, K
    JOURNAL OF THE PHYSICAL SOCIETY OF JAPAN, 1998, 67 (02) : 481 - 486
  • [26] A Comprehensive Time-Resolved Study of X-Ray Signals in a 4 kJ Dense Plasma Focus Facility
    Roomi, A.
    Habibi, M.
    JOURNAL OF FUSION ENERGY, 2012, 31 (05) : 480 - 488
  • [27] Feasibility of X-ray interstitial radiosurgery based on plasma focus device
    Tartari, A
    Da Re, A
    Mezzetti, F
    Angeli, E
    De Chiara, P
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2004, 213 : 607 - 610
  • [28] Soft X-Ray Emission Optimization Study with Nitrogen Gas in a 1.2 kJ Plasma Focus
    M. Shafiq
    S. Hussain
    M. Sharif
    M. Zakaullah
    Journal of Fusion Energy, 2001, 20 : 113 - 115
  • [29] Experimental study of soft X-ray intensity with different anode tips in Amirkabir plasma focus device
    MORTEZA HABIBI
    MAHSA MAHTAB
    Pramana, 2016, 87
  • [30] Soft X-ray Emission Optimization Study with nitrogen gas in a 1.2 kJ plasma focus
    Shafiq, M
    Hussain, S
    Sharif, M
    Zakaullah, M
    JOURNAL OF FUSION ENERGY, 2001, 20 (03) : 113 - 115